CONTROL VALVES
Model C000 Globe Style Main Valve
Model CA000 Angle Style Main Valve
Model
C & CA
(Full Ported)
STANDARD FEATURES
• Fusion Epoxy Coating
• 1-1/4"-10" Unleaded Bronze Valve Trim
• 12"-36" Stainless Steel Valve Trim
• EZ off Jack Screws (Covers & Seat Rings)
• Body Drain Plug
• Rugged Dependability
The Flomatic Model C000/CA000 Main Valve is a self contained hydraulically operated, single diaphragmactuated globe or angled body valve with no pilot controls. The valve has three major components: the
body with a removable seat, the cover with bushing, and the diaphragm assembly. The diaphragm
assembly is the only moving part. The cover forms a sealed chamber above the diaphragm to separate
operating pressure from line pressure. Long service life and dependable operation are ensured due to
packless construction. The valve is designed for use with various types of pressure and/or electric
controls to provide the desired control of pressure or flow for a variety of water system applications. The
Flomatic Model C000/CA000 is the basic valve used for all Flomatic full port automatic control valves.
Principal of Operation
Full Flow Tight Closure
Full flow is achieved by releasing control
pressure from the cover chamber to a
lower pressure zone which allows line
pressure to open the diphragm assembly.
Tight closure is achieved by applying inlet
pressure to the cover chamber to leverage
the differential force of the larger
hragm surface area against the smaller
dia
seat area.
Modulating control is achieved by utilizing
a pressure regulating control valve to
automatically compensate for line pressure
fluctuations.
Modulated Flow
Glens Falls, NY 12801
Phone (518) 761-9797
www.flomatic.com
C000/CA000 Technical Data
December 02, 2010 Rev. A (04/12/11)
MADE IN
THE U.S.A.
1

Specifications
COVER
Model
C & CA
HEX CAP
SCREW
STEM
SPRING
TOP
DIAPHRAGM
PLATE
TOP
DIAPHRAGM
PLATE
SPOOL
SEAT SEAL
COVER
BEARING
STEM JAM NUTS
DIAPHRAGM
STEM ORING
STEM ORING
SEAT PLATE
Glens Falls, NY 12801
Phone (518) 761-9797
www.flomatic.com
STEM
HEX CAP SCREW
(6" & LARGER)
SEAT RING
SEAT O-RING
BODY
(GLOBE OR ANGLE)
C000/CA000 Technical Data
December 02, 2010 Rev. A (04/12/11)
2

Functional Data
Headloss Chart
Pressure Loss (PSI)
U.S. System: CV = U.S. GPM @ 1 PSI with 60° F Water
Metric System: Cv = LPS @ 1 kPa with 15° C Water
Equivalent Lengths of Pipe are determined from the formula: L = Kd/12f
Model
C & CA
Cavitation Chart
Flow Rate in Gallons per Minute (GPM)
(Inlet Pressure vs. Outlet Pressure)
CAVITATION ZONE
OUTLET PRESSURE NOT
RECOMMENDED
CONSULT FACTOR
OPERATING ZONE
RECOMMENDED OUTLET PRESSURE
FOR PRESSURE REGULATING VALVES
Inlet Pressure Up Stream (PSI)
Glens Falls, NY 12801
Phone (518) 761-9797
www.flomatic.com
Outlet Pressure Down Stream (PSI)
C000/CA000 Technical Data
December 02, 2010 Rev. A (04/12/11)
3

Dimensions
J
C (1-1/4" - 12")
Model
C & CA
N
CA (1-1/4" - 12")
G
H
K
A
B
C
D
E
F
I
KK
C (14" - 36")
Glens Falls, NY 12801
Phone (518) 761-9797
www.flomatic.com
C000/CA000 Technical Data
December 02, 2010 Rev. A (04/12/11)
MADE IN
THE U.S.A.
4