![](/html/2e/2ec7/2ec7256f7fb138d07d8abe8339a490e821ba92ecb17c463c8c715031212c0ff4/bg2.png)
Backsplash - Vertical Installation
58.000
Side Splash
250.000
Top of back splash
is covered by the hood.
J63-1451 End Cap
Back Splash
Ordering Notes:
1. Vertically installed backsplash is always used on height requirements over 48".
2. End caps (part # J63-1451) are used to cover raw edges on ends of backsplash sections.
3. Divider bars (part # J64-1450)are used to cover raw edges between adjacent panels.
4. When hoods are ordered end to end, backsplash should be ordered under hood #1.
5. Sidesplash & backsplash calculations are the same.
Calculating Back & Side Splash:
Inside Corner
J63-1451 End Cap
102.000
80.000
J64-1450 Divider Bars
J64-1450 Divider Bars
# OF FULL PANELS (round down)= TOTAL SECTION LENGTH / W, (W = Max Panel Width*)•
LAST PANEL WIDTH = REMAINDER x W (for non-insulated backsplash, subtract 1/16" x #of divider bars from last panel width to compensate for divider bar width).•
If width of last panel is less than 20", transfer 12" from second to last panel to last panel. Transfer additional 6" if last panel is still less than 20".•
Example (above): # of Full Panels = 250 / 48 = 5.208 = 5 (round down). Width of remaining panel = 0.208 x 48 - 5/16 = 9-11/16, add 12 for final panel width of 21-11/16. •
Panel widths will be 4 panels at 48", 1 panel at 36", 1 panel at 21-11/16".
Equal Panel Length Option: # OF PANELS (ROUND UP) = TOTAL LENGTH / W (W = Max Panel Width*). INDIVIDUAL PANEL WIDTH (NON-INSULATED) = (TOTAL SECTION •
LENGTH - 1/16 x (# OF PANELS - 1)) / # OF PANELS. INDIVIDUAL PANEL WIDTH (INSULATED) = TOTAL SECTION LENGTH / # OF PANELS.
Equal Panel Length Example (above): # of Panels = 250/48 = 5.208 = 6 (round up). Individual panel width = (250 - 1/16 x 5) / 6 = 41.615 (non-insulated)•
Calculating # Of End Caps - Part # J63-1451:
TOTAL REQUIRED END CAP LENGTH = HEIGHT X 2.•
# OF END CAPS = TOTAL REQUIRED END CAP LENGTH / 84 + 1 (round up).•
Example (above): Total required end cap length = 80 X 2 = 160. # of End Caps = 160/84 + 1= 2.905 = 3 pc. •
Calculating # Of Divider Bars - Part # J64-1450:
TOTAL REQUIRED DIVIDER BAR LENGTH = (# PANELS - 1) x HEIGHT.•
# OF DIVIDER BARS = TOTAL DIVIDER BAR LENGTH / 84 + 1 (round up).
•
Example (above): Total required divider bar length = (6-1) x 80 = 400. #of Divider Bars = 400/84 + 1= 5.761 = 6 pc.•
*MAX PANEL SIZE FOR VERTICAL BACK SPLASH
Uninsulated = 48" X 192"
1" Insulated = 45" X 190"