Flir DM62, DM64, DM66 Instruction Manual

USER MANUAL
True RMS Digital MultiMeter Series
Models DM62, DM64, and DM66
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
2
Table of Contents
1. ADVISORIES 4
1.1 Copyright 4
1.2 Quality Assurance 4
1.3 Documentation 4
1.4 Disposal of Electronic Waste 4
2. SAFETY 5
3. INTRODUCTION 7
4. METER AND DISPLAY DESCRIPTIONS 8
4.1 Front and Back Meter Descriptions 8
4.2 Rotary Function Selector 9
4.3 Control Buttons 9
4.4 Display Description 10
5. BASIC OPERATION AND FEATURES 11
5.1 Powering the Meter 11
5.2 Intelligent Auto Power OFF (APO) 11
5.3 LCD Backlight 11
5.4 Auto/Manual Range Mode 11
5.5 True RMS Response 11
5.6 Crest Factor 11
5.7 Out-of-range Warning (O.L) 11
5.8 Data Hold 12
5.9 Relative Zero Mode 12
5.10 VFD Mode (Low Pass Filter) Models DM64/DM66 only 12
5.11 MAX-MIN-AVG Record Mode 12
5.12 Test Lead Input Warning 12
5.13 Auto Voltage AC/DC Detection in ‘Lo Z’ mode (DM64/DM66 only) 12
6. MEASUREMENTS 13
6.1 AC/DC Voltage Measurements (VFD and Frequency on DM64/DM66) 13
6.2 Low Impedance (Lo Z) Auto-Voltage Measurements (DM64/66 only) 14
6.3 Line Frequency Measurements (DM64/DM66 only) 15
6.4 Resistance and Continuity Measurements 16
6.5 Capacitance (DM64/DM66) and Diode Measurements 17
6.6 AC/DC mV and Temperature (DM64/DM66) Measurements 19
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
3
6.7 A, mA, A Current Measurements with Frequency (DM64/DM66) 21
6.8 NCV (Non-Contact Voltage) Detection 22
7. MAINTENANCE 23
7.1 Cleaning and Storage 23
7.2 Battery and Fuse Replacement 23
7.3 Disposal of Electronic Waste 23
8. SPECIFICATIONS 24
8.1 General specifications 24
8.2 Electrical Specifications 25
9. TECHNICAL SUPPORT 29
10. THREE-YEAR LIMITED WARRANTY 30
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
4

1. Advisories

1.1 Copyright

© 2018, FLIR Systems, Inc. All rights reserved worldwide. No parts of the software
including source code may be reproduced, transmitted, transcribed or translated into any language or computer language in any form or by any means, electronic, magnetic, optical, manual or otherwise, without the prior written permission of FLIR Systems. The documentation must not, in whole or part, be copied, photocopied, reproduced, translated or transmitted to any electronic medium or machine readable form without prior consent, in writing, from FLIR Systems. Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names or company names referenced herein are used for identification only and are the property of their respective owners.

1.2 Quality Assurance

The Quality Management System under which these products are developed and manufactured has been certified in accordance with the ISO 9001 standard. FLIR Systems is committed to a policy of continuous development; therefore, we reserve the right to make changes and improvements on any of the products without prior notice.

1.3 Documentation

To access the latest manuals and notifications, go to the Download tab at:
http://support.flir.com. It only takes a few minutes to register online. In the download
area you will also find the latest releases of manuals for our other products, as well as manuals for our historical and obsolete products.

1.4 Disposal of Electronic Waste

As with most electronic products, this equipment must be disposed of in an environmentally friendly way, and in accordance with existing regulations for electronic waste. Please contact your FLIR Systems representative for more details.
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
5

2. Safety

Safety Notes
This manual contains information and warnings that must be followed for operating the meter safely and maintaining the meter in a safe operating condition. If the meter is used in a manner not specified by the manufacturer, the protection provided by the meter may be impaired.
Terms in this manual
WARNING Identifies conditions and actions that could result in serious injury or even
death to the user.
CAUTION Identifies conditions and actions that could cause damage or malfunction in
the instrument.
WARNING
To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use.
Keep your hands/fingers behind the hand/finger barriers (of the meter and the test probe assembly, where applicable) that indicate the limits of safe access of the hand-held parts during measurements. Inspect lead wires, connectors, and probes for damaged insulation or exposed metal before using the meter. If any defects are found, replace them immediately. Only use the probe assembly provided with the meter or a UL Listed Probe Assembly to the same meter ratings or better.
IEC 61010-031 requires exposed conductive test probe tips to be 4mm for CAT III & CAT IV ratings. Refer to the category markings on your probe assemblies as well as on the add-on accessories (like detachable Caps or Alligator Clips), if any, for applicable rating changes.
Observe proper safety precautions when working with voltages above 33 Vrms, 46.7 Vpeak or 70 VDC. These voltage levels pose a potential shock hazard to the user. Before and after hazardous voltage measurements, check the voltage function on a known source such as line voltage to determine proper meter functioning.
CAUTION
Disconnect the test leads from the test points before changing functions.
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
6
International Electrical Symbols
Marking of Electrical and Electronic Equipment (EEE). Do not dispose of this product as unsorted municipal waste. Contact a qualified recycler
Caution! Refer to the explanation in this Manual
Caution! Possibility of electric shock
Earth (Ground)
Meter protected throughout by Double Insulation or Reinforced insulation
Fuse
Direct Current (DC)
Alternating Current (AC)
3 Three-phase Alternating Current
Measurement Categories
Measurement Category IV is applicable to test and measuring circuits connected at
the source of the building’s low-voltage MAINS installation. Examples are measurements on devices installed before the main fuse or circuit breaker in the building installation. Measurement Category III is applicable to test and measuring circuits connected to the distribution part of the building’s low-voltage MAINS installation. Examples are measurements on distribution boards (including secondary meters), circuit-breakers, wiring, including cables, bus-bars, junction boxes, switches, and socket-outlets in the fixed installation, and equipment for industrial use and some other equipment such as stationary motors with permanent connection to the fixed installation.
CENELEC DIRECTIVES
The instruments conform to CENELEC Low-voltage directive 2014/35/EC, Electromagnetic compatibility directive 2014/30/EU and RoHS directive 2011/65/EU.
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
7

3. Introduction

Thank you for selecting the FLIR DM6x Digital Multimeter. This meter can measure up to 600V and 10A AC/DC. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
Features
6000 Count (3-5/6 digits) backlit LCD with 5 reading per second update rate Auto Power OFF Measures ACV, DCV, Resistance, Continuity, Capacitance*, Diode, DCA, ACA,
Temperature*, line Frequency*, non-contact Voltage (NCV)
True RMS responding Auto AC/DC detection for voltage measurements* Lo Z (low impedance) for ghost voltage protection* Auto ranging VFD feature (low pass filter for AC voltage measurements)* MIN-MAX-AVG Reading Memory Relative Zero mode Equipped with test leads, batteries, printed Quick Start (full User Manual available
on FLIR website http://support.flir.com), and type K thermocouple*
Optional accessories: Banana plug to type-K socket plug adaptor*, magnetic hanger,
and carrying pouch
*Applies to models DM64 and DM66 only
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
8

4. Meter and Display Descriptions

4.1 Front and Back Meter Descriptions

1. Non-Contact Voltage Detector
2. LCD
3. Control buttons
4. Rotary Selector Switch
5. ‘A’ Current input terminal
6. ‘uA, mA’ Current input terminal
7. COM (negative -) input terminal
8. Positive (+) input terminal for all inputs except Current
9. Battery compartment lock and fuse access
10. Test Lead holders
11. Battery compartment and fuse access
12. Tilt stand
Fig. 4-1 Front and Back Views (DM66)
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
9

4.2 Rotary Function Selector

Lo Z (low impedance) mode with Auto ACV/DCV detection (DM64/DM6) Meter power off
AC/DC Voltage and VFD (low pass filter) modes (VFD available in models DM64/DM66 only)
Resistance and Continuity measurements
Temperature (DM64 and DM66 only) and AC/DC milli-volt measurements
Capacitance (DM64 and DM66 only) and Diode measurements
AC/DC Amp and milli-amp current measurements
AC/DC micro-amp current measurements

4.3 Control Buttons

Long press to switch LCD Backlight ON/OFF
Mode select button. For rotary switch positions with more than one function, use this button to select the desired function
Short press to select MANUAL mode and to change ranges, long press to return to AUTO. Also used to select sensitivity in NCV mode and trigger level for line frequency measurements (DM64/DM66)
Short press to access MIN-MAX-AVG Record mode. Short press to step through MIN-MAX-AVG readings. Long press to exit
Long press the Relative/Zero button to switch the mode ON/OFF. When switched on, the displayed reading is stored as reference/offset value
Data Hold button. Short press to freeze/unfreeze displayed reading
Frequency button (DM64/DM66). Short press to view frequency for AC measurements
Short press the Non-Contact Voltage (NCV) button to switch ON/OFF. Use RANGE to select high (H) 24~1000V or low (L) 100~1000V sensitivity
FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
10

4.4 Display Description

Fig. 4-2 LCD Display Icons
1. Automatic Range mode
2. Data Hold
3. Maximum, Minimum, and Average Reading Record modes
4. High Sensitivity NCV mode
5. Low Sensitivity NCV mode
6. VFD (low pass filtering) mode*
7. Continuity test
8. Relative/Zero function
9. Units of measure
10. Diode test
11. Main display digits
12. Battery status
13. Lo Z (low impedance) mode*
14. Minus symbol
15. AC and DC symbols
16. Automatic ACV/DCV detection in Lo Z mode*
*Models DM64/DM66 only
Loading...
+ 22 hidden pages