FlexLink X85 XBUТ 180С User Manual

Interspace divert and merge module
XBUT 180 C
5110813-01
5110815-01
User documentation ver 1.0
QR 6621379
Interspace divert and merge module XBUT 180 C
Observe! The sensor set-up depends on pallet size.
Interspace divert and merge module XBUT 180 C
Function description
The Interspace module is divided into Stop position and Return stop position.
This function supports ”non-memory transports”.(see below)
Stop position
The RFID-reader of the Stop position identifies the pallet, which is necessary for deciding whether the pallet should go straight or go through the short-cut. Single pallets or multiple simultaneous pallets are allowed to be released downstream the straight flow, while single pallets are allowed through the short-cut one at a time.
Return stop position
Return stop
position
Single or multiple pallets are let downstream along the return flow when no other pallet is on the way from the Stop position.
Cycle time at conveyor speed 5 m/min
1-2 5 sec 3-4 8 sec 1-4 10 sec
4
1 2
Non-memory transports
The ”Non-memory transport” design makes the module less sensitive to unnormal situations as when a pallet is by mistake lifted-off the module during a transport.
3
Stop
position
Internal positions
Data:
Pre-stop queue pressure limit: 100 kg
Notes:
The station is not equipped with any downstream maxqueue sensor as the design is only possible with an overview of the line as a whole.
The sensor configuration is depending on the size of pallet. Mixed flow with reference to pallet length is not possible.
Sensor Sensor
Stop
Flow
Independent of where a pallet is inside the module, it is always detected by a sensor. It is detected from the moment it leaves a stop. As the module monitors the sensors directly, if a pallet is lifted off, the module auto­recovers and release the second pallet downstream.
The alternative would be that the sensor placing is such that it requires a memory to remember the pallet­transport. While the memory is on, it stops the second pallet from being released by the stop. The disadvantage of this method is that if the pallet is lifted­off, the memory would stay on until forever, thus never releasing the second pallet. A situation is arisen which could be difficult to understand and solve.
Sensor
Memory
Memory transport
Stop
Flow
r
o
s
n
e
S
Non-memory transport