Note. The sensor set-up depends on pallet size.

X85 Pallet

Function description

The Locating station is divided into Pre-stop position and Process position.

Pre-stop position

The Pre-stop position is relieving the Process position of the queue-pressure. The RFID-reader of the Pre-stop identifies the pallet, affecting the efficiency as pallets with other destination quickly pass the Process position.

Process position

The Process position receives one pallet at a time from the Pre-stop. If the pallet should be processed, it is caught by the integrated stop. Thereafter it is located and process is allowed to start.

Pre-stop Process

position position

Internal positions

Data:

Pre-stop queue pressure limit: In progress Process position accuracy: In progress Cycle time: In progress

Notes:

The station is not equipped with any downstream maxqueue sensor as the design is only possible with an overview of the line as a whole.

The sensor configuration is depending on the size of pallet. Mixed flow with reference to pallet length is not possible.

X85 Pallet

Initiators and actuators

B1

A3

 

A1

A2

B2

 

B3

B10

B4

 

Initiators

Actuators

B1

Pre-stop

A1

Pre-stop. Single acting.

B2

In position

A2

Stop. Single acting.

B3

Locating Up

A3

Locating. Double acting.

B4

Locating Down

 

 

B10 RFID