Note. The sensor set-up depends on pallet size.
X85 Pallet
Function description
The Locating station is divided into Pre-stop position and
Process position.
Pre-stop position
The Pre-stop position is relieving the Process position of
the queue-pressure. The RFID-reader of the Pre-stop
identifies the pallet, affecting the ef fi cie ncy as pallets with
other destination quickly pass the Process position.
Process position
The Process position receives one pallet at a time from
the Pre-stop. If the pallet should be processed, it is caught
by the integrated stop. Thereafter it is located and process
is allowed to start.
Pre-stop
position
Data:
Pre-stop queue pressure limit: In progress
Process position accuracy: In progress
Cycle time: In progress
Process
position
Internal positions
Notes:
The station is not equipped with any downstream
maxqueue sensor as the design is only possible with
an overview of the line as a whole.
The sensor configuration is depending on the size of
pallet. Mixed flow with reference to pallet length is not
possible.
X85 Pallet
Initiators and actuators
B1
B10
A1
A3
B2
A2
B3
B4
Initiators
B1 Pre-stop
B2 In position
B3 Locating Up
B4 Locating Down
B10 RFID
Actuators
A1 Pre-stop. Single acting.
A2 Stop. Single acting.
A3 Locating. Double acting.
X85 Pallet