Flex-a-Lite Trimline Electric Fans User Manual

Trimline Electric Fans
Installation Instructions
Puller Mode (as shipped from the manufacturer) Through Core Mounting Instructions
(SEE DIAGRAM “A”)
1.Position the electric fan against the radiator, and mark mounting hole locations.
2. Pass a small Phillips screwdriver through the marked holes, carefully spreading the fins to allow easy passage for the nylon bolts. Fit the bolts to the mounting tabs, and pass the bolts through the shroud holes in the radiator.
3.Push on the speed nuts until snug.
4. Cut off the end of the mounting bolts, leaving 1/4” remaining.
Pusher Mode Through Core Mounting Instructions
1.Remove retaining clip from motor shaft.
Push Nut
Diagram A
Puller Mode
Shown
Nylon Bolt
2.Remove fan blade, flip it over, and re-fit to shaft. Make sure that pin on shaft is seated into groove in fan hub. Replace retaining clip.
3. Proceed with instruction above.
in front of the radiator. Modifications may be necessary to accommodate the fan.
Note: some vehicles have a/c condensers or tranny coolers mounted
Wiring Instructions
Important: Puller fans use:
Blue or Red wire is positive (+).
Black wire is negative (-).
Important: Disconnect the battery prior to wiring any of the products below.
Direct Connect: (Fan will operate when the ignition is “on”)
1.Attach the positive fan motor wire to a 12 V positive ignition controlled source, e.g. fuse box. Note: We recommend the use of a 20 Amp inline fuse (not included) for each fan.
2.Attach the negative fan motor wire to a suitable ground. Note: Connect directly to battery negative terminal if possible.
3. Reconnect the battery.
The Flex-a-lite Limited Warranty
Flex-a-lite Consolidated, 7213-45th St. Ct. E., Fife, W A 98424, Telephone No . 253-922-2700, w arrants to the original purchasing user , that all Flex-a-lite products to be free of defects in material and workmanship for a period of 365 days (1 year) from date of purchase. Flex-a-lite products failing within 365 days (1 year) from date of purchase may be returned to the factory through the point of purchase, transportation charges prepaid. If, on inspection, cause of f ailure is determined to be defective material or workman­ship and not by misuse, accidental or improper installation, Flex-a-lite will replace the product free of charge, transportation prepaid. Flex-a-lite will not be liable for incidental, progressive or consequential damages. Some states do not allo w the exclusion or limitation of incidental or consequential damages, so the abo ve limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may have other rights, which vary from state to state. The Flex-a-lite warranty is in compliance with the Magnuson-Moss W arranty Act of 1975.
Important: Pusher fans use:
Black wire is positive (+).
Blue or Red wire is negative(-).
Rev. 04-20-10 99820