Chevy S-10 &
S-10
Blazer Electric Fan
Part #60: Puller mode, includes thermostatic control.
Part #65: Puller mode, does not include controls.
Mounting
Installation Instructions
1. Disconnect the battery ground cable.
2. Remove the top (3) shroud screws. Reference
Diagram B
3. Remove the (2) screws on each side of the
upper shroud.
4. Remove the top of the shroud.
5. Remove the (4) nuts securing the clutch/fan
assembly to the water pump shaft and
remove assembly.
6. Reinstall nuts on water pump shaft to secure
water pump pulley.
7. Install spacer and mounting bracket on the
bottom of the electric fan shroud securing
with the nuts and bolts provided. Note:
Shroud holes for mounting brackets are
offset more from edge of shroud on the top
side.
Reference Diagram A for bracket installation
Reference Diagram B for proper fan orientation
Mount Control Module on the
Passenger Side of the Vehicle
8. Lift radiator approximately 2 inches and
hook the bottom mounting bracket under the
lower radiator C-channel so that the fan is
mounted on the center of the radiator Note:
Installation is facilitated by angling the top
of the fan away from the radiator while
hooking the bottom bracket.
9. While holding the top of the electric fan
against the radiator install the top mounting
spacer and bracket using the nuts and bolts
provided.
10. Follow wiring instructions in the next
section.
11. Reinstall upper radiator shroud and fasten
using the original bolts.
12. Reconnect battery ground cable.
Bracket
Spacer
Upper Shroud
Top Shroud
Screws
(1982 to 2002)
Diagram A
Control Module
Diagram B
Side Screws
rev. 06-22-05 99925 page 1 of 2

Wiring - Diagram C
Mandatory Connections
1. Connect the positive “+” terminal to a low amp 12 volt positive (+) source. (i.e. fuse box) using
thin red wire and fuse taps (if necessary) provided in the kit.
Note: Attach this wire to an ignition controlled source to stop the fan unit from operating when
the vehicle is shut off.
2. Connect the “B” terminal to a high amp 12 volt positive (+) power source. (i.e. battery, starter
solenoid) using the thick red wire and in line fuse holder provided in the kit (do not install the
fuse at this time).
3 Connect the “G” terminal to ground. (i.e. chassis, negative(-) side of battery) using the thick
black wire provided in the kit.
5. If you have air conditioning: with 3-way connector provided, pass the A/C clutch positive(+)
wire (connected to the A/C compressor) through the connector. Place the green wire provided
into the closed end of the connector. Crimp metal plate. Snap plastic cover into place. Attach
green wire to the "C" terminal of the control box.
Air Conditioning Relay activates fan when A/C is turned on
6. Insert probe in radiator core near upper hose. Install rubber cap over end of probe..
Adjusting the Temeprature Control
1. Turn the adjustable control knob completely clockwise.
2. Idle the vehicle, when the vehicle is at 5 to 10 degrees higher than “normal” turn the adjustable
control knob counter clockwise until the fan comes on.
3. The fan will now activate at this temperature automatically and will shut off after it has cooled
the vehicle down 7 to 11 degrees. Note: It is typical for this fan unit to cycle on and off.
Optional Connection—
*Illuminated Manual Switch
(Note: Based on Flex-a-lite’s manual switch
part # 31148, not included)
(this step is based on Flex-a-lite’s part #31148, other
swtches will cause this unit to fail)
1. Connect the “M” terminal to terminal 1
on the switch.
2. Connect terminal 2 to a 12 volt positive(+) source.
3. Attach terminal 3 to ground to illuminate the switch.
Diagram C
Control Box T erminals & Connections
Mandatory Connections
+ 12 volt positive source
G Ground
B 12 volt positive source
C Air conditioning relay
Optional Connection
M Manual switch
Ground
Control Box
G
+
12 Volt Positive Source
optional
12 Volt Source
Ground
(Illuminate switch)
3-way
connector
A/C positive (+)
wire from clutch
Fuse Holder
12 Volt Positive
Source
C
M
B
12 3
*WARNING: If not using Flex-a-lite’s
illuminated switch (PN #31148), you must
disconnect the switch ground.
The Flex-a-lite Limited Warranty
Flex-a-lite Consolidated, 7213-45th St. Ct. E., Fife, W A 98424, T elephone No. 253-922-2700, warrants to the original purchasing user, that all Flex-a-lite product s to be free of defects
in material and workmanship for a period of 365 days (1 year) from date of purchase. Flex-a-lite products failing within 365 days (1 year) from date of purchase may be returned to
the factory through the point of purchase, transportation charges prepaid. If, on inspection, cause of failure is determined to be defective material or workmanship and not by misuse,
accidental or improper installation, Flex-a-lite will replace the fan free of charge, transportation prepaid. Flex-a-lite will not be liable for incidental, progressive or consequential
damages. Some states do not allow the exclusion or limitaion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives
you specific legal rights and you may have other rights, which vary from state to state. The Flex-a-lite warranty is in compliance with the Magnuson-Moss W arranty Act of 1975.
rev. 06-22-05 99925 page 2 of 2