28.5 kg
Safety and warnings
WARNING!
Electrical Shock Hazard
Always disconnect the appliance from the mains power
supply before carrying out any maintenance or repairs.
Connection to a good earth wiring system is essential
and mandatory.
Alterations to the domestic wiring system must only be
made by a qualified electrician.
Failure to follow this advice may result in electrical shock
or death.
WARNING!
Weight Hazard
The wall canopy is heavy. Please ensure adequate care
is taken when installing the wall canopy to prevent
personal injury. The wall canopy must be installed onto
a solid wall, stud, beam or truss. Weight of the product is
28.5 kg.
1
Important safety precautions
To avoid hazard, follow these instructions carefully before
installing or using this appliance.
Please make this information available to the person installing the
appliance – doing so could reduce your installation costs.
This appliance must be installed and connected to the mains power
supply only by a suitably qualified person according to these
installation instructions and in compliance with any applicable
local building and electricity regulations. Failure to install the
appliance correctly could invalidate any warranty or liability claims.
2
Safety and warnings
If the power supply cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified person in
order to avoid a hazard.
To comply with electrical safety regulations, this canopy must
be connected to a socket near the appliance. The socket must be
accessible, or have an accessible isolating switch, to enable the
end user to isolate the canopy from the power for the purpose of
internal cleaning or maintenance.
A power outlet should be within 750 mm of the motor assembly
and can be either on the wall, behind the chimney or in the ceiling.
Always switch the power off prior to installation, servicing or
cleaning the wall canopy.
Ducting accessories are not supplied. All ducting must comply with
local requirements and building codes.
Before connecting any pipes, consult municipal ordinances to
ensure that any applicable regulations concerning the discharge of
exhaust air are adhered to and request permission from the person
in charge of the building.
Exhaust air must not be discharged into an existing flue that is used
for exhausting fumes from appliances burning gas or other fuels.
There must be adequate ventilation of the room when the wall
canopy is used at the same time as appliances burning gas or other
fuels. (A partial vacuum in the room could result in too high a
concentration of gas in the air).
When the canopy is turned on at the same time as other appliances
powered by energy other than electricity, the air outlet must not be
greater than 4 Pa (4x10-5 bar).
The minimum distance between the cooktop surface and the filters
of the wall canopy shall be 600 mm, or 650 mm if installed over a
gas cooktop.
Stainless steel is very easily damaged during installation if abraded
or knocked by tools. It is recommended to protect the top of the
canopy with cardboard or polystyrene during the installation to
minimise the risk of damage occurring.
Safety and warnings
Children must be supervised to ensure that they do not play with
the hood.
This canopy is not designed to be used by people (including
children) with reduced physical, sensorial or mental capacity, or
who lack experience or knowledge about it, unless they have had
supervision or instructions on how to use the hood by someone
who is responsible for their safety.
You must read the details concerning the method and frequency of
cleaning.
There is a fire risk if cleaning is not carried out in accordance with
the instructions.
Never leave frying food unattended since grease can overheat and
catch fire. The risk of fire is even greater in the case of used oil.
Do not flambé under the wall canopy.
Never use the wall canopy without the filters in place.
During climatic conditions causing electrical interference, it is
possible that the device may stop working. By switching the device
OFF and ON the device will resume normal operation safety.
During an electrostatic discharge (ESD) it is possible that the device
will stop working. By switching the device OFF and ON the device
will again work as intended. There is no risk and no risk will appear.
3
4
Unpacking your wall canopy
1 2
34
56
Installation instructions
Please read this instruction manual carefully in order to obtain the best results from the use of
the wall canopy.
If you need any technical help or would like more information about our products, please do not
hesitate to contact your local Fisher & Paykel retailer.
Preparing the wall canopy for installation
Before installing your wall canopy:
Please read the instructions carefully.
Unpack the canopy and check that all functions are working.
Ensure that the voltage (V) and the frequency (Hz) indicated on the serial plate match the
voltage and frequency at the installation site.
Check that the area behind the installation surface to be drilled is clear of any electrical cables or
pipes, etc.
The stainless steel and glass surfaces of the canopy are very easily damaged during installation if
grazed or knocked by tools. Please take care to protect the surfaces during installation.
Protect the cooktop surface below with cardboard, or the like, to prevent damage occurring
whilst the wall canopy is being installed above.
The manufacturer shall not be liable for failure to observe all safety regulations in force for the
correct and normal operation of electrical parts.
5
Ducting options
Recirculation
To recirculate your wall canopy, please purchase a recirculation kit (part no. 791820). The
recirculation kit is required to channel the air out through the side-vents at the top of the flue.
Note: a ducting hole is not required in the wall or ceiling if a recirculation kit is fitted.
Ducting
For ducted installation, it is recommended that you use 150 mm diameter, rigid or semi-rigid
ducting. This will require a 160 mm (min) round hole in the ceiling, which the decorative
chimney will cover. Care should be taken to align the canopy with the decorative chimney
allowing sufficient clearance to accommodate the ducting.
For optimal efficiency, use smooth-wall, solid galvanized or plastic ducting for reduced noise and
increased airflow. Flexible ducting should only be used as a last resort (ie in difficult installations)
and if used, ensure that it is pulled tight.
The smoother, straighter and shorter the ducting the quieter and more efficient the wall canopy
will perform.
All ducting must comply with local requirements and building codes.
6
Installation instructions
1
2
34
Installation instructions
56
7
78
8
Installation instructions
910
1112
Operating your wall canopy
Touch control panel
This panel is located on the front part of the hood and includes
the following functions:
Filter cleaning alert indicator (ref. A).
Activated regularly as a reminder of the need to clean filters and
deactivated with a single press.
Timer button (ref. B).
The fan will operate for 15 minutes before automatically turning off.
Light button (ref. C).
Turns the lights ON and OFF. Press and hold button to adjust the level
of light.
Power ON/OFF (ref. D).
9
E
D
Fan speed buttons (1st, 2nd, 3rd and 4th speed) (Ref. E).
Using the automatic timer
To operate the automatic timer:
1
Select the fan speed.
2
Press the button for two seconds until the LED light blinks.
3
The timer will work for 5 minutes at the current speed and 5 minutes
at each of the lower speeds until coming to a complete stop. At the
end of this time, the motor will stop and the light will go out.
To cancel the timer: press the timer button once and the motor willstop.
C
B
A
Fig.1 Touch control panel
10
Cleaning and maintenance
Important!
Never use abrasive or oil based cleaners
Maintenance
Before performing any cleaning or maintenance on your wall canopy, ensure that the power
supply is switched OFF to the hood.
The wall canopy should be cleaned regularly using a mild, liquid detergent to avoid a build up of
grease occurring. Grease deposits are corrosive which can damage to your wall canopy.
Note: in areas of high humidity or coastal environments, cleaning should be carried out frequently.
Aluminium filters
Depending on use, and at least once a month, the aluminium grease filters should be removed
and cleaned in a dishwasher or with hot soapy water.
If washed in a dishwasher, the filters should be placed in an upright position to prevent food
from falling on them.
After rinsing and drying, replace the filters by reversing the following instruction for removal.
Note: some discolouration of the frames may occur.
Removing the aluminium filters:
1
Click
3
2
Click
4
Click
Cleaning and maintenance
Carbon filters
Active carbon filters are disposable items designed to remove grease and odours from cooking
vapours before the air is channelled back into the kitchen. The active carbon filters must be
replaced periodically to work properly, at least once every three months, depending on the
frequency with which the wall canopy is used.
Fitting the carbon filter:
12
34
11
Replacing the light bulb
1
Before changing the light bulb, ensure the wall canopy is disconnected from the power supply.
2
Remove the aluminium grease filter (refer to page 10 to see how to do this).
3
If canopy is in recirculation mode, remove charcoal filter (refer to fitting the carbon filter section
above to see how).
4
Replace light bulbs with maximum 50 Watts.
5
Reinstall carbon filter if required and refit the aluminium filter.
AccessoryPart number
Recirculation kit791820
Replacement carbon filter791758
Replacement aluminium filter791761
Replacement light bulb791822
12
Warranty and service
Before you call for service or assistance ...
Check the things you can do yourself. Refer to the installation instructions and your user guide
and check that:
1
your product is correctly installed
2
you are familiar with its normal operation.
If after checking these points you still need assistance, please refer to the Service & Warranty
book for warranty details and your nearest Authorised Service Centre, or contact us through our
website listed on the back cover.
The product specifications in this booklet apply to the specific products
and models described at the date of issue. Under our policy of continuous
product improvement, these specifications may change at any time. You
should therefore check with your Dealer to ensure this booklet correctly
describes the product currently available.
GB IN07.2013PN - 590628 A CATA PN - 60812660
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.