Fisher & Paykel DishDrawer DD60S Series Installation Instructions Manual

(1,1) -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM
(1,1) -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM
Installation instructions
DishDrawer®
DD60S models
NZ AU GB IE
Important!
SAVE THESE INSTRUCTIONS
The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.
1
Important safety instructions!
Installation of this DishDrawer® requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the DishDrawer® installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the DishDrawer®. This DishDrawer® is manufactured for indoor use only. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations. The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required.
The switched power outlet must be outside the DishDrawer® cavity, so that it is accessible after
installation.
Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord. If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage.
Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not
be reused. Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims.
If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle,
boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product.
WARNING!
Electrical shock hazard
Before installing the DishDrawer®, remove the house fuse or open the circuit
breaker.
This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug. The plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances. WARNING- Improper connection of the equipment­earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly earthed.
Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box.
Failure to follow this advice may result in electrical shock or death.
WARNING!
Cut hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.
(1,2) -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM
(1,2) -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM
23
PRODUCT DIMENSIONS CABINETRY DIMENSIONS
Installation diagrams for illustration purposes only
C
D
K
H
I
J
A
Product dimensions ( (mm)
overall height* of product
A
overall width of product
B
overall depth of product (excl. curvature/handle)
C
depth of drawer (open) (excl. curvature/handle)
D
height* of chassis
E
depth of chassis (incl. trimseal)
F
depth of drawer front panel (excl. curvature/handle)
G
depth of curvature or handle
H
height of drawer front
I
height of venting area at base of product
J
height of installation bracket slots (on top of chassis)
K
Installation diagrams for illustration purposes only
B
B
A
C
F
G
E
C
F
K
H
Pre nished
DD60S
LCD
409 409 409
599 599 599
570 570 570**
538 538 538
409 409 409
552 552 552
18 18 18
11 41 n/a
394 398 398 min
79 9
22 2
Flat door
DD60S
Pre nished
Integrated
DD60S
Cabinetry dimensions (mm)
inside height of cavity
A
inside width of cavity
B
inside depth of cavity
C
Minimum clearances (mm)
2.5 mm
Pre nished
DD60S
LCD
412 412 412
600 600 600
580 580 580
Flat door
DD60S
Pre nished
Integrated
DD60S
*Chassis heights include bracket slots ** Panel thickness - 18 mm
Note: for Pre nished Flat door models, the height from the top of handle to the top of door - 64 mm
2.5 mm
13 mm
(2,1) -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM
(2,1) -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM
4
PARTS SUPPLIED
Drain hose support (1)
If the Drain hose supplied is not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose by 3.6m. The kit is available from the nearest Fisher & Paykel Authorised Service Centre or our local website listed at the end of this document.
CAVITY PREPARATION
5
Drain hose joiner (1)
Wire clip (1)
Clamp (1)
Top mounting brackets (2)
OPTIONAL
10 mm
Phillips 16 mm screws (7)
Moisture protection tape must
Rubber washer for inlet hose (1)
Moisture protection tape (1)
(to prevent moisture damage)
Note: Services can be located either side of DishDrawer®.
be applied.
These marks indicate formed bracket screw locations.
Preferred position. If adequate clearance, services hole can be higher.
*
If hole is higher, ensure drain hose is routed straight into the waste connection.
min. ø
Water Connection
Recommended COLD (Maximum 60°C). ¾ “ BSP (GB20) to suit flat washer.
Water Pressure Max Min
Water softener models 1 MPa (145 psi) 0.1 MPa (14.5 psi) Other models 1 MPa (145 psi) 0.03 MPa (4.3 psi)
60 mm
*
*
max.
450 mm
Water supply
Drains will need to be separated to satisfy kosher requirements. We suggest you confirm acceptability with your local rabbi in respect to kosher installations.
Important!
Adjacent cabinetry must not extend above cavity base
200 mm
min.
220-240 VAC min. 4.5 A
Loading...