Fisher & Paykel DD24SCTX9N Installation manual

SINGLE DISHDRAWERTM DISHWASHER
DD24SI, DD24STI & DD24SHTI models
INSTALLATION GUIDE
US CA
59186 A 08.17
!
WARNING!
Electrical Shock Hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. If permanently connecting the dishwasher, be sure the power is isolated and the dishwasher unplugged.
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly grounded.
If the dishwasher is installed as a permanently connected appliance: GROUNDING INSTRUCTIONS - This appliance must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance. Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box. Failure to follow this advice may result in electrical shock or death.
IMPORTANT SAFETY INSTRUCTIONS
Installation of this dishwasher requires basic mechanical and electrical skills.
Be sure to leave these Instructions with the Customer.
Installation must comply with your local building, electricity, and plumbing regulations.
At the completion of the dishwasher installation, the Installer must perform the Final Checklist.
Remove all packaging materials supplied with the dishwasher.
This dishwasher is manufactured for indoor use only.
Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations.
The dishwasher MUST be installed to allow for future removal from the enclosure if service is required.
The switched power outlet must be outside the dishwasher cavity, so that it is accessible after installation.
Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord and hoses.
If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage.
Make sure only new hoses are used for connection (supplied with the dishwasher). Old hoses should not be reused.
Failure to install the dishwasher correctly could invalidate any warranty or liability claims.
If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product.
This dishdrawer is intended for connection to the hot-water supply.
Failure to install the dishwasher correctly could invalidate any warranty or liability claims.
!
WARNING!
Fitting integrated front panels requires access to electrical service areas. This work must be performed and certified by a qualified electrical service technician.
Electrical Shock Hazard WARNING: To reduce the risk of electrical shock, fire, or injury to persons, the installer must ensure that the dishwasher is completely enclosed at the time of installation. Before fitting the front panels and connecting the ‘knock to pause’ module (if necessary), the installer must ensure that the dishwasher is disconnected from the power supply. After installing the front panels, the installer must ensure that the following components are electrically grounded: the panel bracket and any custom metal component (e.g. handle) that extends past the rubber seal. Failure to follow these warnings may result in electrical shock, injury or fire.
!
WARNING!
Cut Hazard Take care - panel edges are sharp. Failure to use caution could result in injury or cuts.
1
Ensure the product is not plugged in when fitting custom panels.
Installation of custom panels requires basic mechanical and electrical skills.
Installation must comply with your local building and electricity regulations.
Failure to install the custom panels correctly could invalidate any warranty or liability claims.
IMPORTANT!
SAVE THESE INSTRUCTIONS
The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.
2 PARTS SUPPLIED
Drain hose support (1)
Phillips 16 mm screws (7)
Drain hose joiner (1)
38 mm bottom fixing screws & metal washers (2)
Rubber washer for inlet hose (1)
(comes already fitted)
Wire clip (1)
(for securing Drain hose joiner)
Clamp (1)
(for securing Drain hose joiner)
Moisture protection tape (1)
(to prevent moisture damage to cabinetry)
Side mounting bracket kit (A and B) (2) OPTIONAL
Cavity Bracket Kit (1)
(supplied with Tall Height Models only)
(fitted before installation in order to conceal the gap at the top of the cavity left after installation.)
Top mounting brackets (2) OPTIONAL
Edge Protector (1)
(If the services hole is through a metal partition, the hole must be protected with the Edge Protector supplied to prevent damage to the power cord or hoses.)
Panel bracket (1) & Knock-to-Pause Module (1)
(shipped fixed to product)
If the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hoses by 11’ 10” (3.6m). The kit is available from the nearest Fisher & Paykel Authorized Service Center, or Toll free 1.888.936.7872 or www.fisherpaykel.com
Panel mounting screws (6)
External Venting kit (1)
2
3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION
3-A REMOVE THE DRAWER 3-B REMOVE THE ACCESS COVER & REMOVE POWER
To prevent kinked hoses
Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after
1
removal.
Clip
1
Clip
1
3
2
3
4” (100mm)
Press the release tabs in on either side and push back to release drawer from runners. Lift drawer off runners.
Sit the drawer down
Rotate the drawer clockwise (max. 90 and rest on side.
4
Push drawer runners back in on either side.
4
Push drawer runners back in on either side.
o
)
1 With a flat-bladed screwdriver, push
in the clips and slide out the access cover.
2 Unscrew the electronics module
cover.
3 Carefully pull out the electronics
module and rest on the chassis base out of the way.
4 With a screwdriver, unclip the plastic
harness cover and hinge open.
5 Slide the terminal block cover
sideways to unlock and hinge open to access the terminal block.
6 Unscrew the Live, Neutral and Earth
wires as shown.
7 Unscrew the three screws on the
base as shown and remove the cord from the product.
Access cover
5
4
Remove existing power cord
7
6
2
Electronics module
Terminal Block cover
7
3
3-C TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS
8
9
IMPORTANT!
Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics module.
3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION
12
13
11
10
14
8 Fit a suitable cable clamp for the
conduit through the metal knockout.
Ensure wiring is routed through or
under under housing ribs.
9 Screw down the Live, Neutral and
Earth wires correctly.
10 Push the plastic harness cover back
over. It should clip back into place
11 Fold down and slide back the
terminal block cover.
12 Refit the electronics module back
into position, being careful of wiring.
13 Replace the screw securing the
electronics module.
14 Slide the access cover back,
ensuring the 2 clips shown are fully locked in place.
NOTE: Use copper conductors
only.
Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.
2
3-D REFIT THE DRAWER ONTO THE RUNNERS & CLOSE
Lift or rotate counterclockwise the drawer back onto the drawer runners on either side.
4” (100 mm)
3
1
Release tab
4
Pull the release tabs forward on both sides 4” (100 mm). Ensure the tabs are fully pulled forward and click into place.
4
4 PRODUCT DIMENSIONS
E
B
PLAN
A
H
D
I
C
F
PROFILEFRONT
PRODUCT DIMENSIONS INCHES (MM) INCHES (MM)
Overall height of product
A
Overall width of product
B
Overall depth of product
C
Depth of chassis (to back of front drawer panel)
D
Depth of drawer front panel
E
Height of drawer front panel min. 16 1/16” (408)
F
Height of chassis
G
Ventilation gap below drawer front panel
H
Maximum extension of drawer
I
1
includes 1 ⁄16” (2mm) high bracket slots 2 assuming a front panel thickness of 11/16” (18mm)
3
recommended for a 1 ⁄16” (2mm) ventilation gap below panel, if cavity height is 16 1/4” (412mm)
4
recommended for a 1 ⁄16” (2mm) ventilation gap below panel
1
1
2
2
G
STANDARD
HEIGHT
MODELS
DD24SI
16 1/8” (410) min. 17 7/8” (454)
23 9/16” (599) 23 9/16” (599)
22 1/2” (571) 22 1/2” (571)
21 3/4” (553) 21 3/4” (553)
5/8” - 13/16” (16-20) 5/8” - 13/16” (16-20)
3
min. 17 13/16” (452)
16 1/8” (410) 17 7/8” (454)
min. 1/6” (2) min. 1/6” (2)
21 7/16” (545) 21 7/16” (545)
TALL
HEIGHT
MODELS
DD24STI
DD24SHTI
4
5
K
5 CABINETRY DIMENSIONS
L
Bracket slots
PLAN
STANDARD
HEIGHT
MODELS
DD24SI
CABINETRY DIMENSIONS INCHES (MM) INCHES (MM)
Inside height of cavity
J
Inside width of cavity
K
Inside depth of cavity
L
min. 16 1/4” (412) min. 18” (456)
23 5/8” (600) 23 5/8” (600)
min. 22 1/16” (560) min. 22 1/16” (560)
Minimum clearances from adjacent cabinetry
TALL
HEIGHT
MODELS
DD24STI
DD24SHTI
J
PROFILE
Custom Filler Panel
J
min. 1/2” (13 mm) clearance from a corner cupboard
min. 1/16” (2 mm) clearance to adjacent cupboard door
If your cavity height leaves a visible gap under your countertop when you open the drawer:
Fit the supplied cavity bracket (or a custom cavity filler panel) before installation in order to conceal any gap at the top of the cavity left after installation.
PROFILE
6
6 CUSTOM DRAWER PANEL SPECIFICATIONS
FRONT PANEL MATERIAL SPECIFICATIONS
5/8 - 13/16” (16 - 20mm) panel thickness
Adequately sealed to withstand moisture (122OF/50OC @ 80% RH) Because of it being a hot and wet environment generally, the back and sides of the panel should be completely sealed with a waterproof vapour barrier (ie polyurethane) to prevent damage to the panel.
The back of the panel (including any integrated handle) should be completely flush so that the seal between the panel and the rubber trim is maintained.
Installation outside these specs may result in condensation on cabinetry surfaces.
Maximum weight of panel: 20lb (9kg)
The following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry.
WIDTH OF THE PANEL
Measure A (the width between adjacent door/drawer fronts) and write it in the first box below, then complete the equation.
Clearance to adjacent
A
cabinet front
WIDTH OF PANEL
- 2x =
(min. 1/16” (2mm))
HEIGHT OF THE PANEL
(23 7/16”-24 3/16” (596-615mm))
1/16” (2mm)
Note: when the top of the dishwasher has to be lower than the adjacent cabinetry, the top of the panel can extend above the chassis where required, however a min. 1/16” (2mm) gap to the benchtop must be maintained.
A
min. 1/16” (2mm) min. 1/16” (2mm)
min. 1/16” (2mm)
B
PANEL
WIDTH OF PANEL
HEIGHT OF PANEL
Ventilation Gap min. 1/16” (2mm) with External Venting Kit installed
B
Ventilation Gap
(min. 1/16” (2mm))
HEIGHT OF PANEL
=-
Ventilation Gap (min. 1/16” (2mm)) with External Venting Kit installed
7
Loading...
+ 18 hidden pages