mains electricity supply before carrying
out any work or maintenance on it.
Connection to a good earth wiring
system is essential and mandatory.
Alterations to the domestic wiring
system must only be made by a qualified
electrician.
Failure to follow this advice may result
in electrical shock or death.
IMPORTANT SAFETY INSTRUCTIONS!
Particular attention shall be given to the relevant
requirements regarding ventilation.
Read these instructions carefully before installing
this product.
Please make this information available to the
person installing the appliance as it could reduce
your installation costs.
This appliance is to be installed and serviced only
by an authorised person.
Installation must comply with your local building
and local electricity regulations.
The manufacturer accepts no responsibility for
the incorrect installation of appliances. Incorrect
installation may result in personal injury, damage
to property and may invalidate any warranty or
WARNING!
Cut hazard
Take care - some panel edges are sharp.
Failure to use caution could result in
injury or cuts.
liability claims.
Do not modify this appliance.
Do not use or store flammable materials on or near
this appliance.
Packing elements (eg plastic bags, polystyrene
foam, staples, packing straps etc) and tools should
not be left around during and after installation,
especially if they are within easy reach of children,
as these may cause serious injuries.
Page 4
1
SAFETY AND WARNINGS
Before you install the appliance,
please make sure that
a suitable disconnection switch is incorporated in
if the cooktop is installed above an oven, the oven
has a built-in cooling fan.
the installation will comply with all clearance
4
the permanent wiring, mounted and positioned
to comply with the local wiring rules and
regulations. A means of disconnection with at
least a 3 mm air gap contact separation in all
poles must be incorporated into the fixed wiring
in accordance with the wiring rules, unless the
local wiring rules allow for alternative means.
the benchtop is made of a heat resistant material.
the power supply cable is not accessible through
cupboard doors or drawers.
there is adequate flow of cool air from the
cabinetry to the base of the cooktop. You may
ventilate from adjacent cupboards, but ensure
that the available air supply will not be restricted.
the ventilation area must be at least two o 50mm
holes or of an equivalent area.
the isolating switch is easily accessible by the
customer.
you use heat-resistant and easy-to-clean finishes
requirements and applicable standards and
regulations.
you consult local building authorities and by-laws
if in doubt regarding installation.
When you install the appliance
We do not recommend you flush mount or seal
this appliance into the bench with silicone or
glue. Doing so will make future servicing difficult.
Fisher & Paykel will not be liable for any costs
associated with removing or replacing a sealed-in
appliance, nor for repairing any damage that may
be incurred by doing this.
Seal exposed bare edges of the cutout with an
oil-based paint or moisture-proof polyurethane to
prevent possible moisture creeping between the
cooktop trim and the benchtop.
Take extreme care not to chip, crack, or break the
top glass surfaces during installation. A heavy
(such as ceramic tiles) for the wall surfaces
surrounding the cooktop.
the cooktop will not be installed directly above a
dishwasher, fridge, freezer, washing machine or
clothes dryer, as the humidity may damage the
cooktop electronics.
metal tool or part accidentally dropped on the
glass could damage it.
If, after following the instructions given, correct
performance cannot be achieved, please contact
your nearest Fisher & Paykel Authorised Service
Centre, Customer Care, or contact us through our
local website listed at the end of this document.
Page 5
2
PARTS SUPPLIED
5
Clamping brackets (4)
and screws (4)
CG302DTB only
Clamping brackets (2)
and screws (2)
Installing multiple products
Foam tape (1)
Note: We recommend installing products in separate cutouts with a minimum distance of 5 mm between the glass edges.
If installing multiple products adjacent to each other within the same cutout, a separate joining strip kit is required for installation.
The kit is available from the nearest Fisher & Paykel Authorised Service Centre or our local website listed at the end of this document.
If installing different products adjacent to each other (eg a wok burner next to an induction cooktop), the minimum clearance measurements for the different products may vary. Always use the greater distance.
Page 6
A
D
B
E
C
G
F
H
I
4
PRODUCT & CABINETRY DIMENSIONS
Note: Electrical connection is
made at the right rear
6
Product and cabinetry dimensions(mm)
overall height of product
A
(including terminal block below top of chassis)
overall width of product300600600750900
B
overall depth of product 530530530530530
C
height of chassis
D
(including terminal block below top of chassis)
width of chassis254546546716852
E
depth of chassis478478478478482
F
overall width of cutout265560560725870
G
overall depth of cutout490 490 490 490 494
H
corner radius of cutout max. 10max. 10max. 10max. 10max. 10
I
TOP
REAR
SIDE
CI302DTB
5454545454
CI603DTB
CI604DTB
CI754DTB
4949494949
TOP
FRONT
CI905DTB
Page 7
5
min. 75 mm
Alternatively
2x 50mm holes
in side wall
to allow adequate
cool air
min. 4 mm
min. 4 mm
Drawer or other obstruction
Oven with cooling fan
Ventilation gap
must be present
20 mm
Alternatively
2x 50mm holes
in side wall
to allow adequate
cool air
E
CLEARANCE DIMENSIONS
7
C
A
C
ISO
E
B
FRONT
D
WARNING!
This cooktop requires
adequate supply of cool air
to fully function.
The base of the cooktop
must have direct
unrestricted ventilation to
the room where the
cooktop is installed. Follow
the requirements shown.
Clearance dimensions(mm)
minimum clearance from rear edge of cutout to nearest combustible surface3030303030
A
minimum clearance from glass surface to rangehood650650650650650
B
minimum clearance from side edges of cutout to nearest combustible surface
C
minimum clearance from benchtop to overhead cabinet not directly above the cooktop450450450450450
D
minimum clearance below top of benchtop to:
E
rear top of oven* installed below cooktop or cabinetry6565656565
* The oven installed below the cooktop MUST have a cooling fan.
CI302DTB
CI603DTB
CI604DTB
CI754DTB
3030302525
CI905DTB
Page 8
6
FLUSH MOUNTING INSTALLATION (NOT RECOMMENDED)
Note: Electrical connection is
made at the right rear
We do not recommend flush mounting and sealing as
servicing requires the cooktop to be removed from the
benchtop. The owner carries all risk for flush mounting the cooktop. The owner must ensure the cooktop has
been cut out from the benchtop before servicing can
be carried out. Fisher & Paykel will not be liable for any
costs associated with removing or replacing a flushmounted and/or sealed-in product, nor for repairing
any damage that may be incurred by doing this.
WARNING!
C
TOP
B
A
E
REARSIDE
Product and cabinetry dimensions(mm)
D
CI302DTB
F
CI603DTB
CI604DTB
CI754DTB
8
G
G
HH
IJ
TOP
K
FRONT
CI905DTB
L
overall height of product
A
(including terminal block below top of chassis)
overall width of product300600600750900
B
overall depth of product 530530530530530
C
height of chassis
D
(including terminal block below top of chassis)
width of chassis254546546716852
E
depth of chassis478478478478482
F
overall width of routered recess305605605755905
G
I
width of cutout265560560725870
G
overall depth of routered recess535535535535535
H
I
depth of cutout490490490490494
H
corner radius of cutout max. 10max. 10max. 10max. 10max. 10
I
corner radius of routered recessmax. 2max. 2max. 2max. 2max. 2
J
height of routered recess55555
K
minimum clearance below top of benchtop to:
rear top of oven* installed below cooktop or cabinetry
L
thermal protection barrier
5454545454
4949494949
65
65
65
65
65
65
65
65
65
65
Page 9
6
FLUSH MOUNTING INSTALLATION (NOT RECOMMENDED)
9
6a
ROUTER THE BENCHTOP TO THE
SPECIFIED DEPTH
5 mm
6d
APPLY SILICONE
6b
FIT THE CLAMPING BRACKETS
No. of brackets and slot positions depends on model
view from below
12-40mm
Fit a minimum of 2 brackets on opposing sides
6e
WIPE OFF EXCESS SILICONE
40mm+
6c
MASK OFF THE AREA TO BE
SILICONED
3
6f
IF REMOVING PRODUCT, CUT
AROUND THE SILICONE
1
2
min. 150 OC rated
Ensure silicone does not leak underneath glass.
TO REMOVE PRODUCT
2
1
Page 10
78
DISCARD PACKAGINGPLACE COOKTOP UPSIDE DOWN
10
Important!
To avoid damage to the glass, ensure there is a protective cover underneath it.
Recycle responsibly
9
APPLY ADHESIVE FOAM TAPE AROUND GLASS EDGE
Foam Tape
1
Apply the foam seal around the glass
overhang, 5 mm in from the edge of
Adhesive side
Ensure edge of tape
lines up with outer
edge of cooktop
the glass, with the adhesive side facing
down to form a continuous seal around
the cooktop.
2
Using a sharp cutter or trimmer knife,
trim the excess sealing material around
the edge of the cooktop. Take care not
to damage the benchtop.
10
LOWER GENTLY INTO THE CUTOUT
Page 11
11
CONNECTING THE COOKTOP TO THE MAINS POWER SUPPLY
11
Important!
This cooktop must be connected to the mains power supply only by a suitably qualified person.To connect the cooktop to the mains power supply, do not use adapters, reducers, or branching devices, as
they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its temperature will
not exceed 75
Before connecting the cooktop to the mains power supply check that:
the domestic wiring system is suitable for the power drawn by the cooktop.The voltage corresponds to the value given in the rating plate
The power supply cable sections can withstand the load specified on the rating plate.
*The CI302DTB comes supplied with a cable. This must be wired into a 16A plug.
Important!
Check with an electrician whether the domestic wiring system is suitable without alterations. Any alterations
must only be made by a qualified electrician.
1213
FIT CLAMPING BRACKETS BASED ON THE
BENCHTOP THICKNESS
CI603DTB, CI604DTB, CI754DTB
Single-phase connection
220-240V~
12345
PE
N
L
CI905DTB
Single-phase connection
220-240V~
4
123
L
5
PE
N
SECURE TO BENCHTOP
Two-phase connection
380-415V 2N~
12345
PE
L1L
Three-phase connection
N
2
380-415V 3N~
12345
PE
L1L3L
N
2
No. of brackets and slot positions depends on model
view from below
12-40mm
40mm+
Fit a minimum of
2 brackets on opposing sides
Secure on at least
2 opposing sides
Repeat on all the other brackets
Page 12
14
FINAL CHECKLIST
12
TO BE COMPLETED BY THE INSTALLER
Is the cooktop earthed?
Check that there is an adequate and constant flow of cool air from the
cabinetry to the base of the cooktop.
Check that the power supply cable is not accessible via cupboard doors or
drawers and that it is NOT touching the cooktop.
Is the cooktop clamped down securely?
Check that the pan detection feature is working correctly. Turn on each
cooking zone without putting any cookware on them. Are all the displays
flashing?
Check that all the cooking zones function correctly. Place suitable pans with
water in them on each zone, then turn all of them on to a high setting. Is the
water heating?
Are all touch controls and displays functioning?
Check that the Bridging function works (CI302DBT & CI604DBT models only).
Place a pan of water in each cooking zones (or one covering both cooking
zones). Touch both control panels simultaneously. Do the bridging zone
indicators light up? Is the water heating?
To check that the ‘hot surface’ indicators function correctly, turn off all the
zones. Is H displayed in all the cooking zone displays?
Have you demonstrated the basic operation to the customer?
Make sure you explain to the customer about
1
the importance of taking note of the safety warnings at the beginning
of the user guide, especially for persons with pacemakers or other
electrical implants.
2
the ‘hot surface’ indicators.
3
using induction suitable cookware only.
4
the pan detection feature.
Installer’s name:
Installer’s signature:
Installation company:
Date of installation:
LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER
Important!
SAVE THESE INSTRUCTIONS
The models shown in this document may not be available in all markets and are subject to change
at any time. For current details about model and specification availability in your country, please
visit our local website listed at the end of this document or contact your local Fisher & Paykel
dealer.
www. sherpaykel.com
Page 13
13
Page 14
Page 15
Page 16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.