Fisher Mounting Instructions: DVC6200 or DVC2000 Digital Valve Controller on 1051 Size 33 and 1052 Size 20 and 33 Actuator (Window Mount) | Fisher Manuals & Guides

_
DVC6200 or DVC2000 Digital Valve
Mounting Instructions
D103447X012
May 2010
Size 20 and 33 ActuatorV (Window Mount)
Use these instructions to mount a Fisher® FIELDVUETM DVC6200 or DVC2000 digital valve controller on Fisher 1051 Size 33 and 1052 Size 20 and 33 actuators.
Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any installation operations:
Always wear protective clothing, gloves, and
eyewear.
Do not remove the actuator from the valve while
the valve is still pressurized.
Disconnect any operating lines providing air
pressure, electric power, or a control signal to the actuator. Be sure the actuator cannot suddenly open or close the control valve.
Use bypass valves or completely shut off the
process to isolate the control valve from process pressure. Relieve process pressure from both sides of the control valve.
Vent the pneumatic actuator loading pressure
and relieve any actuator spring precompression.
Use lock-out procedures to be sure that the
above measures stay in effect while you work on the equipment.
Check with your process or safety engineer for
any additional measures that must be taken to protect against process media.
Refer to figure 2 and the parts list for mounting parts identification. Refer to the DVC6200 or DVC2000 digital valve controller instruction manual for digital valve controller parts identification. Refer to the appropriate actuator instruction manual for actuator installation, operation, maintenance, and parts identification. Figure 1 shows the arced feedback assembly.
1. Isolate the control valve from the process line pressure and release pressure from both sides of the valve body. Shut off all pressure lines to the actuator, releasing all pressure from actuator. Use lock-out procedures to be sure that the above measures stay in effect while you work on the equipment.
_____________________________________________________________________________________________________
www.Fisher.com
Controller on 1051 Size 33 and 1052
2. Remove the cover plate screws and cover plate from the actuator, if present.
3. Install the cam (key 1) on to the lever of actuator using hex head mach screws (key use of arced feedback mechanism. Consult the appropriate actuator instruction manual for proper actuator disassembly and reassembly. Ensure that the cam is oriented as shown in figure 2.
4. Attach the mounting adaptor (key 3) to the yoke using the four hex socket cap screws (key 4).
5. Attach the digital valve controller to the arced feedback assembly (key 5) and tighten the hex socket cap screws (key 6).
6. Install the arced feedback assembly (key 5), along with the digital valve controller, to the mounting adaptor (key 3) using hex socket cap screws (key 7) as shown in figure 2. Ensure that the roller of arced feedback assembly is centered and resting on the cam surface.
7. Make pneumatic and electrical connections to the digital valve controller as described in the digital valve controller instruction manual.
8. It may be necessary to fine tune the placement of the cam so that the digital valve controllers receives the proper feedback.
9. Setup and calibrate the digital valve controller as described in the instruction manual or quick start guide.
For additional information concerning mounting, setup, calibration, and maintenance of the DVC6200 or DVC2000 digital valve controller, refer to the appropriate instruction manual.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for the selection, use, and maintenance of any product remains with the purchaser and end user.
2). It will be necessary for
Note
DVC6200 or DVC2000 Digital Valve
(
)
o
33
Controller on 1051 Size 33 and 1052 Size 20 and 33 Actuators
PART LIST
KEY QTY DESCRIPTION
1 1 CAM
2 2 10-24UNCX0.38” HEX HD SCREWS
3 1 ADAPTOR, MTG
4 4 5/16”-18UNCX0.62” SOCKET SCREWS
5 1 ARCED FEEDBACK ASSEMBLY
6 4 M8X1.25X16 SOCKET SCREWS
7 4 5/16”-18UNCX0.62” SOCKET SCREWS
NOTE: DVC6200 uses 4 M8 socket screws (key 6) for mounting onto arced feedback assembly.
DVC2000 uses 3 M8 socket screws (key 6) for mounting onto arced feedback assembly.
Window Mount
GE42131
Figure 1. Arced Feedback Assembly
F
Mounting Instructions
D103447X012
r 1051/1052 size 20-
May 2010
Figure 2. Mounting Parts Identification
Loading...