DVC62000 or DVC2000
Mounting Instructions
D103455X012 February 2011
Use these instructions to mount a Fisher® FIELDVUE™ DVC6200 or DVC2000 digital valve 2052, size 1, 2, or 3 actuators.
Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any installation operations:
Always wear protective clothing, gloves, and eyewear.
Do not remove the actuator from the valve while the valve is still pressurized.
Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the actuator cannot suddenly open or close the control valve.
Use bypass valves or completely shut off the process to isolate the control valve from process pressure. Relieve process pressure from both sides of the control valve.
Vent the pneumatic actuator loading pressure and relieve any actuator spring precompression.
Use lock-out procedures to be sure that the above measures stay in effect while you work on the equipment.
Check with your process or safety engineer for any additional measures that must be taken to protect against process media.
Refer to figure 1 to select the appropriate arced feedback assembly per the actuator requirement. Refer to figure 2 for mounting parts identification for 2052 size 1 and figure 3 for 2052 size 2 and3. Refer to the DVC6200 or DVC2000 digital valve controller instruction manual for digital valve controller parts identification. Refer to the appropriate actuator instruction manual for actuator installation, operation, maintenance, and parts identification.
1. Isolate the control valve from the process line
pressure and release pressure from both sides of the valve body. Shut off all pressure lines to the actuator, releasing all pressure from actuator.
Use lock-out procedures to be sure that the above measures stay in effect while you work on the equipment.
_____________________________________________________________________________________________________
www.Fisher.com
controller on Fisher
Size 1,2or3 Actuato
Digital Valve Controller on 2052
Window Mount
2. Remove the cover plate screws and cover plate from the actuator, if present.
3. Refer to figure 4 and 5 to confirm that the 2052 actuator has the updated lever arm.
4. Install the cam (key 1) on to the lever of actuator. It will be necessary for use of arced feedback mechanism. Consult with the appropriate actuator instruction manual for proper actuator disassembly and reassembly.
5. For 2052 size 1, 2, and 3 actuators attach the cam (key 1) to the lever arm of actuator using hex head cap screws (key 2). Ensure that the cam is oriented as shown in figure 2 or 3.
6. For 2052 size 1 actuators attach the mounting adapter (key 3) to the yoke using the hex socket cap screws (key 4). For actuator size 2 and 3 mounting adapter (key 3) is not required.
7. Attach the digital valve controller to the appropriate arced feedback assembly (short stroke or long stroke, key 5) as per the actuator requirement using hex socket cap screws (key 7).
8. Attach the arced feedback assembly (key 5), along with the digital valve controller to the mounting adapter (key 3) for actuator size 1 using hex socket cap screws (key 6) as shown in figure 2 and to the yoke of actuator size 2 and 3 using hex socket cap screws (key 6) as shown in figure 3.
9. Ensure that the roller of arced feedback assembly is centered and resting on the cam surface.
10. Make pneumatic and electrical connections to the digital valve controller as described in the digital valve controller instruction manual.
11. It may be necessary to fine tune the placement of the cam so that the digital valve controller receives the proper feedback.
12. Setup and calibrate the digital valve controller as described in the digital valve controller instruction manual or quick start guide.
For additional information concerning mounting, setup, calibration, and maintenance of the DVC6200 or DVC2000 digital valve controller, refer to the appropriate instruction manual.
DVC6200 or DVC2000
)
Digital Valve Controller on 2052 Size 1
Note Neither Emerson, Emerson Process Management,
nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for the selection, use and maintenance of any product remains with the purchaser and end user.
2 or 3 Actuator (Window Mount
GE42130
ARCED FEEDBACK ASSEMBLY
FOR 2052 SZ 1
Mounting Instructions
D103455X012
February 2011
ARCED FEEDBACK ASSEMBLY
GE42132
ARCED FEEDBACK ASSEMBLY
FOR 2052 SZ 2 & 3
Figure 1. Arced Feedback Assemblies