Installation Instructions
D103400X012
October 2009
Bore Seal
The appropriate Fisherr instruction manual and
warnings associated with that manual must be read
prior to installation of the Fisher Bore Seal to ensure
safe and proper disassembly and reassembly of the
valve. Once the trim has been removed, follow the
steps below to ensure proper installation of the Bore
Seal.
1. Apply a suitable high-temperature lubricant to the
inside diameter of the Bore Seal plug seal. Also,
lubricate the outside diameter of the valve plug
where the Bore Seal plug seal must be pressed into
the proper sealing position (figure 1).
2. Orient the Bore Seal for correct sealing action
based on the process fluid flow direction through the
valve.
D The open interior of the Bore Seal must face up
in a valve with flow-up construction (figure 1).
D The open interior of the Bore Seal must face
down in a valve with flow-down construction
(figure 2).
3. Place the Bore Seal plug seal over the top of the
valve plug. The retainer will help guide the Bore Seal
down onto the plug. Do not force the Bore Seal over
the plug (figure 3). For flow down constructions, skip
to step 5.
RETAINER
PISTON RING
5. Apply a suitable high-temperature lubricant to the
threads on the plug. Then, place the Bore Seal
retainer onto the plug and tighten the retainer using
an appropriate tool such as a strap wrench. For flow
down constructions, skip to step 7.
6. Remove the retainer and then the installation
tool. Place the Bore Seal retainer back onto the plug
and tighten the retainer using an appropriate tool
such as a strap wrench.
7. Using an appropriate tool such as a center
punch, stake the threads on top of the plug in one
place to secure the Bore Seal retainer.
8. Once the Bore Seal as been installed, please
refer back to the appropriate Fisher valve body
instruction manual to replace, machine, and/or
reassemble all appropriate parts.
RETAINER
PLUG
FLOWDOWN
Figure 2. FlowDown Fisher Bore Seal Construction
PISTON RING
CAGE
SEATING AREA
BORE SEAL
CAGE
SEATING AREA
PLUG
FLOWUP
Figure 1. FlowUp Fisher Bore Seal Construction
BORE SEAL
4. An installation tool must be inserted into the Bore
Seal prior to using the retainer to guide it down the
plug.
www.Fisher.com
RETAINER
PISTON RING
BORE SEAL
INSTALLATION
TOOL
BORE SEAL
PLUG
Figure 3. Retainer Guiding Fisher Bore Seal Onto the Plug

Bore Seal
Installation Instructions
October 2009
GE22109-A
F
G
H
E
A
B
C
D
Figure 4. Bore Seal Installation Tool
2

Installation Instructions
October 2009
Table 1. Bore Seal Installation Tool Dimensions
VALV E
PORT
SIZE,
INCH
3.4375
4.28
4.70 4.77 4.35 4.454.47 4.674.65 0.10 1.10 0.32 R.06 GE18267X012
5.1875
5.375 5.49 5.07 5.175.19 5.395.37 0.10 0.10 0.32 R.06 GE22109X012
6.25 6.34 5.92 6.026.04 6.246.22 0.10 0.10 0.32 R.06 GE18266X012
6.75 7.11 6.69 6.796.81 7.016.99 0.09 0.10 0.32 R.06 GE18264X012
7.00 7.11 6.69 6.796.81 7.016.99 0.09 0.10 0.32 R.06 GE18264X012
7.62 7.76 7.34 7.447.46 7.667.64 0.10 0.10 0.32 R.06 GE18263X012
7.75
8.00
8.8125
9.20 9.39 8.97 9.079.09 9.299.27 0.10 0.10 0.32 R.06 GE17916X012
9.9375
10.00 10.12 9.7 9.809.82 10.0210.00 0.10 0.10 0.32 R.06 GE17914X012
10.8125
11.00
11.20 11.35 10.93 11.01511.025 11.26511.255 0.10 0.10 0.32 R.07 GE17905X012
13.75
13.875 14.84 14.42414.416 14.51614.536 14.73614.716 0.1 0.1 0.32 R.05 GE34073X012
14.00
14.75 14.84 14.42414.416 14.51614.536 14.73614.716 0.1 0.1 0.32 R.05 GE34073X012
14.875
16.70
16.9375
17.00
18.25
19.9375
1. For sizes,contact your Emerson Process Management sales office.
A B C D E F G H
Dimensions, Inches (See Figure 4)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Bore Seal
Tool Part
Number
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
3

Bore Seal
Note
Neither Emerson, Emerson Process
Management, nor any of their affiliated
entities assumes responsibility for the
selection, use, or maintenance of any
product. Responsibility for the
selection, use, and maintenance of any
product remains with the purchaser
and end-user.
Installation Instructions
October 2009
Fisher is a mark owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson
Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property
of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they
are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the
designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated
entities assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of
any product remains solely with the purchaser and end-user.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore