Specifications
Body Sizes and End Connection Styles
Inlet: DN 6 (1/4-inch) NPT screwed Outlet: DN 6 or DN 10 (1/4 or 3/8-inch) NPT screwed
Maximum Allowable Inlet Pressure
17 bar (250 psig)
Outlet Pressure Ranges
See table 1
(1)
Maximum Allowable Outlet Pressure
Maximum Emergency Outlet Pressure: 1,4 bar
(20 psig)
Maximum Recommended Outlet Pressure to Avoid Internal Part Damage: 0,21 bar, differential (3 psi)
above outlet pressure setting
(1)
(1)
Proof Test Pressure
All Pressure Retaining Components have been proof tested per Directive 97/23/EC - Annex 1, Section 7.4
Temperature Capabilities
-29 to 71°C (-20 to 160°F)
(1)
Installation
Only qualified personnel should install or service a regulator. Regulators should be installed, operated, and maintained in accordance with international and applicable codes and regulations, and Fisher instructions.
If the regulator vents fluid or a leak develops in the system, it indicates that service is required. Failure to take the regulator out of service immediately may create a hazardous condition.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
Personal injury, equipment damage, or leakage due to escaping fluid or bursting of pressure­containing parts may result if this regulator is overpressured or is installed where service conditions could exceed the limits given in the Specifications section, or where conditions exceed any ratings of the adjacent piping or piping connections.
To avoid such injury or damage, provide pressure­relieving or pressure-limiting devices (as required by the appropriate code, regulation, or standard) to prevent service conditions from exceeding limits.
Additionally, physical damage to the regulator could result in personal injury and property damage due to escaping fluid. To avoid such injury and damage, install the regulator in a safe location.
Clean out all pipelines before installation of the regulator and check to be sure the regulator has not been damaged or has collected foreign material during shipping. For NPT bodies, apply pipe compound to the male pipe threads. For flanged bodies, use suitable line gaskets and approved piping and bolting practices. Install the regulator in any position desired, unless otherwise specified, but be sure flow through the body is in the direction indicated by the arrow on the body.
Note
It is important that the regulator be installed so that the vent hole in the spring case is unobstructed at all times. For outdoor installations, the regulator should be located away from vehicular traffic and positioned so that water, ice, and other foreign materials cannot enter the spring case through the vent. Avoid placing the regulator beneath eaves or downspouts, and be sure it is above the probable snow level.
Overpressure Protection
The recommended pressure limitations are stamped on the regulator nameplate. Some type of overpressure protection is needed if the actual inlet pressure exceeds the maximum operating outlet pressure rating. Overpressure protection should also be provided if the regulator inlet pressure is greater than the safe working pressure of the downstream equipment.
Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external sources or debris in the line. The regulator should be inspected for damage after any overpressure condition.
Startup
The regulator is factory set at approximately the midpoint of the spring range or the pressure requested, so an initial adjustment may be required to give the desired results. With proper installation completed and relief valves properly adjusted, slowly open the upstream and downstream shutoff valves.
D100317XENG
www.FISHERregulators.com
912 Series
Table 1. Outlet Pressure Ranges
NOITARUGIFNOCELBALIAVA
leehwdnahtuohtiw219epyT
leehwdnahtuohtiwH219epyT
leehwdnahhtiwseireS219
EGNARERUSSERPTELTUO
)gisp/.c.wsehcni(rab
)7ot3(71ot7
)01ot5(52ot21
)31ot52.9(23ot32
)42ot21(06ot03
)5.2ot1(271ot96
)5ot7.2(043ot681
)1ot0(96ot0
)5ot0(043ot0
Adjustment
To change the outlet pressure, remove the closing cap or loosen the locknut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease pressure. Monitor the outlet pressure with a test gauge during the adjustment. Replace the closing cap or tighten the locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
To avoid personal injury resulting from sudden release of pressure, isolate the regulator from all pressure before attempting disassembly.
TAGNITTESERUSSERPTELTUOEVOBATNIOPETAMIXORPPA
EGRAHCSIDOTSTRATSFEILERLANRETNIHCIHW
)gisp/.c.wsehcni(rab
)12ot5(25ot21 )03ot8(57ot02
)93ot61(79ot04
)gisp3ot71(012ot24
)8.6ot7.0(74,0ot50,0
)5.21ot8.3(68,0ot62,0
)3ot0(012ot0
)5.21ot0(68,0ot0
Parts List
Key Description
1 Regulator Body 2 Spring Case 3 Closing Cap 4 Adjusting Screw 5 Regulator Spring 6 Relief Valve Spring 7 Spring Seat 8Pin 9 Relief Valve 10 Diaphragm Plate 11 Disc Holder Assembly 12 Fulcrum Rod 13 Machine Screw 14 Machine Screw 15 Diaphragm 16 Vent Screen 17 Closing Cap Gasket
BD4632-H
Figure 1. 912 Series Pressure Regulator Assembly
©Fis her C ontro ls Inte rnati onal, I nc., 2002; All R ights Rese rved
Fisher and Fisher Regulators are marks owned by Fisher Controls International, Inc. The Emerson logo is a trade mark and service mark of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
For information, contact Fisher Controls, International:
Within USA (800) 588-5853 – Outside USA (972) 542-0132 France – (33) 23-733-4700 Singapore – (65) 770-8320 Mexico – (52) 57-28-0888
Printed in U.S.A.
www.FISHERregulators.com
Loading...