Fisher 13080 Parts List

Replacement Parts for Single Deck Dual Control Valve
fisher manufacturing company
65994
SINGLE DECK
DUAL CONTROL
MOUNTING KIT
43001
RIGID
TO SWIVEL
ADAPTER
CONTROL VALVE BODY NOT SOLD SEPARATELY
2000-7500
2000-8000
RED BUTTON
2000-8001
LEVER HANDLE
2000-3002
BIBB CAP
DUCK GASKET
2000-3406
LH CHECK STEM
2000-3407
RH CHECK STEM
2000-6000
2000-0001
RETAINER
ASSEMBLY
73557
SINGLE DECK DUAL CONTROL
HOSE 1/2”F INLET
SCREW
AND
BLUE
BUTTON
73657
73741
WASHER
OR
SPRING
73521
LUBE
2000-0002
LEVER
HANDLE KIT
2000-0002
LEVER
HANDLE KIT
2000-0004
RH CHECK STEM
REPAIR KIT
OR
2000-0005
LH CHECK STEM
REPAIR KIT
3000-0000
RH SWIVEL REPAIR KIT
OR
3000-0001
LH SWIVEL STEM
REPAIR KIT
2000-7500
SCREW
2000-8000
RED BUTTON
AND
2000-8001
BLUE
BUTTON
LEVER HANDLE
2000-3002
BIBB CAP
73657
DUCK GASKET
73741
WASHER
3000-0010
LH SWIVEL STEM
AND
3000-0011
RH SWIVEL STEM
73521
LUBE
Product Installation Guide
Since 1936, Fisher Manufacturing Company has manufactured heavy-duty, high quality plumbing products and hardware specialties for the food service industry. For three generations, the Fisher family has adhered to a strict dedication of and overall value. When you install Fisher products… you install the best. Our hardware is manufactured with the standardization of internal mechanisms. All chrome plating is triple plated copper, nickel and chrome for durability. Every piece of equipment we make is rigorously tested in both our modern in-house testing center and in actual fi eld situations under extreme conditions. Every detail is thoroughly checked. Before we make our products available to you, they pass each and every test. You get proven performance. Guaranteed.
Limited One Year Warranty
Fisher Manufacturing Company warrants its products and parts thereof (except as noted below) against defects in materials or workmanship for a period of one year after the date of original purchase. During this period Fisher Manufacturing Company will replace a defective product or part without charge to you, provided that the entire product is delivered to Fisher Manufacturing Company. All transportation and insurance charges for shipping the product to and from Fisher Manufacturing Company must be borne by you. Charges for transportation and insurance may, at the option of Fisher Manufacturing Company, be refunded depending upon our investigation of the warranty claim. This warranty does not cover external fi nish (except at date of original purchase) or labor costs not specifi cally authorized by Fisher Manufacturing Company.
A full and complete copy of our One Year limited warranty is available upon request.
Warning:This product can expose you to chemicals including Lead, Nickel (Metallic), Di(2-ethylhexyl) phathalate (DEHP) which are known to the State of California to cause cancer, and Lead. Di(2-ethylhexyl) phathalate (DEHP) which are known to the State of Califorina to cause birth defects or reproductive harm. For more information go to:
www.P65Warnings.ca.gov.
#13064 - Single Deck Dual Control Valve with
Swivel Outlet
#13072- Single Deck Dual Control Valve with
Swivel Outlet and Check Valves
#10529 - Single Deck Dual Control Valve with 3/8”
Female Outlet
#13080 - Single Deck Dual Control Valve with 3/8”
Female Outlet and Check Valves
PART NO. 14095
MANFACTURING COMPANY
PO BOX 60, TULARE, CA 93275
(800)421-6162, FAX: (800)832-8238
www.fisher-mfg.com
REV. B
KEEP THIS MANUAL FOR FUTURE REFERENCE
ANSI/A112.18.1M, ANSI/NSF 61.9
fisher manufacturing company - toll free: 800-421-6162 fax: 800-832-8238
www.fi sher-mfg.com
Installation Instructions for Single Deck Dual Control Valves
BE SURE TO CHECK WITH YOUR LOCAL DEPARTMENT HAVING JURISDICTION REGARDING BACKFLOW PREVENTION
Installation Instructions Continued
Installation Notes:
• Be sure to shut off water supply before beginning.
• Use pipe thread sealant such as PST on all threaded joints.
• Check the packaging for missing items BEFORE beginning installation. If items are missing, contact your supplier.
Tools Required for Installation
• Medium Sized Crescent Wrenches
• Pipe Thread Sealant
• 1-1/4” Drill Bit
PST
• Plumbers Tape or Pipe Thread Sealant
Installation of Single Deck Dual Control
1. Drill 1-1/4” rough in hole through the deck where the control valve is to be mounted.
2. Screw the thread shank into the body. Hold the body over the deck hole.
3. Insert the HOT and COLD hoses through the cup washer.
4. Insert both hoses through the deck hole (as shown). Using thread sealant, screw the “COLD” hose into the body.
5. Using thread sealant, screw the HOT hose into the body.
6. (Shown from rear) Push the body down into the deck hole and lift the cup washer up against the deck.
7. (Shown from rear) Lift up the horseshoe washer over the threaded shank, then screw the nut onto the threadshank and up to support the horseshoe washer and the cup washer. Tighten nut until the body is secure in place on the deck.
8. Using washers and thread sealant, connect HOT and COLD supply lines to source. Check for leaks.
RED BUTTON
-BODY
-THREAD SHANK
-CUPWASHER
-HORSESHOE WASHER
-NUT
-HOT HOSE
-COLD HOSE
HOT
COLD
BLUE BUTTON
DECK
TOP
Step 2
RED BUTTON
-BODY
-THREAD SHANK
Step 5
HOT
COLD
BLUE BUTTON
DECK
DECK
Step 6
Step 3
WASHER
Step 4
DECK
CUP
Step 7 & 8
DECK
DECK
TOP
(REAR VIEW)
HOT
HOSE
WASHER
COLD HOSE
Step 1
(Rough-In)
Ø1-1/4"
[31.8mm]
(REAR VIEW)
THREAD SEALANT
GOES HERE
SUPPLY
COLD
HOT
HOTCOLD SUPPLY
Loading...