First Alert One Link SA520B, One Link SCO500B, One Link C0511B, One Link SA511B Specifications

Page 1
Cost Effective Retrofit & Remodel Solutions
All Alarms Respond as One
All Alarms Respond as One
BRK Brands, Inc, 3901 Liberty Street Road Aurora, IL 60504-8122 Phone: 630-851-7330 Tech Services: 800-323-9005 www.firstalert.com, www.brkelectronics.com OneLink is a registered trademark of BRK Brands, Inc. First Alert is a registered trademark of the First Alert Trust used under license. ©2007 BRK Brands, Inc., a Jarden Corporation company (NYSE:JAH) CM2830
Technical specificaTionspRoD
Operating Voltage: Two 1.5V AA Batteries
Humidity Range: 10% - 95% relative humidity (RH)
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Wiring: N/A
UPC: 0 29054 51306 9
Listing: ETL to UL 217 and 2034 standards
Alarm Weight: 8.4 oz.
Individual Carton Weight: 0.66 lbs.
Master Pack Weight: 8.4 lbs.
Pallet Weight: 794.2 lbs.
12 of 5: 100 29054 51306 6
SA511B
Operating Voltage: Two 1.5V AA Batteries
Humidity Range: 10% - 90% relative humidity (RH)
Smoke Sensor: Photoelectric
CO Sensor: N/A
Wiring: N/A
UPC: 0 29054 00292 1
Listing: ETL to UL 217 standard
Alarm Weight: 8.3 oz.
Individual Carton Weight: 0.66 lbs.
Master Pack Weight: 8.4 lbs.
Pallet Weight: 794.2 lbs.
I 2 of 5: 100 29054 00292 8
Operating Voltage: 120V AC with battery backup (Two 1.5V AA Batteries)
Humidity Range: 10% - 90% relative humidity (RH)
Smoke Sensor: Photoelectric
CO Sensor: N/A
Wiring: Quick connect plug with pigtails
UPC: 0 29054 00205 1
Listing: ETL to UL 217 standard
Alarm Weight: 9.3 oz.
Individual Carton Weight: .74 lbs.
Master Pack Weight: 9.4 lbs.
Pallet Weight: 882.2 lbs.
I 2 of 5: 100 29054 00205 3
SA520B
Operating Voltage: Two 1.5V AA Batteries
Humidity Range: 10% - 95% relative humidity (RH)
Smoke Sensor: N/A
CO Sensor: Electrochemical
Wiring: N/A
UPC: 0 29054 00291 4
Listing: ETL to UL 2034 standard
Alarm Weight: 8.4 oz.
Individual Carton Weight: 0.66 lbs.
Master Pack Weight: 8.4 lbs.
Pallet Weight: 794.2 lbs.
I 2 of 5: 100 29054 00291 1
C0511B
common Technical specs
common shipping specs
inDiviDual caRTon masTeR pack
Alarm Dimensions: 5” Dia. X 2” High
Temp Range: 40°F (4°C) to 100°F (38°C)
Audio Alarm: 85 decibel alarm
Operating Frequency: 915 MHz. FCC approved. Complies with Part 15 of the FCC Rules
RF Linking: Automatic with 65,000 security codes
Alarm Reset: Automatic when smoke and/or CO clears, depending on model
Test/Silence Feature: Electronically simulates smoke and/or carbon monoxide condition (depending on model)
Interconnections: Up to 18 units, RF or hardwired, with smoke, carbon monoxide, heat alarms and relays. Maximum 12 smoke alarms
Dimension 5.13”L x 2.38”W x 5.13”H 10.75”L x 7.88”W x 11.06”H
Cube 0.04 ft³ 0.54 ft³
Quantity 1 12
palleT infoRmaTion
Cases Per Layer 22
Number of Layers 4
Cases Per Pallet 88
Units Per Pallet 1,056
Cube 54.0 ft³
SCO500B
Page 2
*Local codes permitting **Note: Based on average retrofitting costs of time, material and labor to connect to existing alarm circuit, drywall repairs, painting, etc. Special cases that require conduit, wire mold, concrete drilling, etc. would add additional costs and increase savings.
• Wireless interconnect technology eliminates the need to pull wires through existing walls
• Save an average of between $150 - $200** per alarm when compared to retrofitting hardwired alarms in existing walls or ceilings
• Faster job turnaround - 4X more jobs completed increases your profits
• Photoelectric sensing technology saves maintenance calls with fewer nuisance alarms.
Cost Effective Retrofit & Remodel Solutions
No matte r what your renovation project, First Al ert One Link provid es a cost e ffective solution:
Home Ad dition Pr ojects:
Using the First Alert OneLink hardwired "Bridge Unit" (SA520B), simply replace one hardwired alarm in the existing section and add one to the new section. Wireless technology saves time, material and labor to connect to the existing alarm circuit. Now add standard BRK hardwired alarms as required in the new section and other First Alert OneLink batter y alarms in the old section to complete the alarm safety system and bring entire home up to code. All alarms, hardwired and batter y, existing and new are now interconnected.
Retrof it Proje cts:
Property Owners, Facility Managers and Electrical Contractors can all benefit from installing First Alert OneLink alarms for existing r etrofit projects. Saving $150 - $200** per alarm and increasing job turnaround 4X are key reasons to consider First Aler t OneLink alarms for all of your renovation projects.
When it comes to alarm renovation and retrofit projects, choices have been limited. Installing battery operated alarms and sacrificing inter connectability or investing in the time and labor to retrofit hardwired alarms have been the only options available.* Until Now! First Alert OneLink eliminates the need to pull wires through existing walls saving time, money and labor.
Putting the Innovation in Renovation
Exclusive! Voice alarm with programmable location. Programmable with up to 11 locations (ex. “basement”). When alarm sounds (if programmed for basement), it will say, “Warning, Evacuate, Smoke in Basement”. If other First Alert OneLink Voice Warning alarms are located throughout the house they will also signal, “Warning, Evacuate, Smoke in Basement”.
• Add additional battery-operated First Aler t Enabled Alarms to create a wireless safety network.
• 5-year limited warranty.
Dust Cover:
Keeps alarm clean during construction.
First Alert®
Technology
All
alarms include these quality innovative features:
Photoelectric Technology: Helps reduce nuisance alarms, especially around kitchens and baths which are more prone to nuisance alarms from cooking smoke and shower steam.
Test/Silence Button:
Tests alarm functions and battery. Silences unwanted alarms. Two silence features - Temporarily silence low battery chirp for up to 8 hours before replacing battery or silence unwanted alarm for several minutes.
Perfect Mount:
mounting bracket keeps alarm secure over a
wide rotation range to allow for perfect alignment.
Optipath 360 Technology™:
Patented technology
provides 360 degrees of direct access to smoke sensor.
RF Interconnect:
Reliable and secure radio frequency communication between alarms. 915 MHz frequency with 65,000 security codes and 3 channel frequency hopping.
Spread Spectrum Horn Tone:
Lower and varying horn frequency makes it easier for elderly with normal age related hearing loss to hear horn. Sweeps through the 2200 - 3400 Hz range.
Latching Features
Alarm Latch: Easily identifies initiating alarm even after alarm condition has subsided. Low Battery Latch: Identifies which unit is in low battery condition. Both features activate for up to 15 minutes. (excludes SA520B)
• Easily expand an existing interconnected 120V AC system by replacing one alarm in the series with this alarm.
• Add additional battery-operated First Aler t Enabled Alarms to expand without wires.
• 10-year limited warranty.
SA520B
Bridge Unit-Wireless Photoelectric 120-Volt AC/DC Hardwired Smoke Alarm
• Easily add smoke alarms to every bedroom to create a wireless safety network.
• 10-year limited warranty.
SA511B
Wireless Photoelectric Battery Smoke Alarm
• Easily add CO alarms outside bedrooms and on every level of the home to create a wireless safety network.
• 5-year limited warranty
C0511B
Wireless Battery Carbon Monoxide Alarm
Exclusive!
W IT H LO C AT IO N
SCO500B
Wireless Photoelectric
Battery Combination
Smoke & CO Alarm
WI TH L O CA TI ON WI TH L O CA TI ON
First Alert OneLink alar ms operate on a "mesh network"; a 2-way communication format that sends, receives and then re-sends the alarm signals. If the initiating alarm signal is blocked from reaching one of the alarms, the mesh network communication reroutes and re-sends the signal via the other alarms as shown in the illustration. With competitive one-way wireless communication, only the initiating alarm sends a signal which may never be received, leaving the blocked alarm deadly silent
.
Competitive Wireless
One-Way Communication
Mesh Network Communication
Master
Bedroom
Hall
Basement
Bedroom
Blocked
Master
Bedroom
Basement
Bedroom
Hall
Blocked
Mesh Network Communication
®
Loading...