FPX 32 DVS Artisan Face
Charcoal 98500507 Antique Copper 98500508 Antique Nickel 98500509
Compatibility
• DVS Insert • 31 DVI Insert
NOTE: On newer units (2008 or later), leave the glass on and move the face connector to the forward
position (see illustration below). For older units, remove the glass.
Remove the face connector bracket
from the heater (on both sides).
Face Connector
Bracket
Re-attach the face connector to the
heater using the forward mounting holes.
Warnings
Denatured
Soft Cloth
Anti-
Oxidizer
Alcohol
Soft Cloth
Packing List
Plated Surfaces Warning:
Any marks left on the optional plated surface may become etched-in by the heat of the
appliance. Use denatured alcohol and a soft cloth to clean.
Copper Surfaces Warning:
Use the included anti-oxidizer to clean the optional copper surface. See the included instruction
sheet for full details.
Warning:
Make sure the heater has fully cooled prior to conducting service.
10-24 Nuts
1/4-20
Screws
Page 1 of 4 17601079 - 5/10/10 © Travis Industries, Inc.
Bracket Installation
FPX 32 DVS Artisan Face
Charcoal 98500507 Antique Copper 98500508 Antique Nickel 98500509
NOTE: The brackets
install with this pair of
closely spaced
flanges at the top.
Install the face mounting brackets to
the heater with the included nuts.