FieldServer ControlNet FS-8700-104 Driver Manual

Driver Version:
1.03
Document Revision:
2
Driver Manual
(Supplement to the FieldServer Instruction Manual)
FS-8700-104 ControlNet X30 Driver
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after November 2011
A Sierra Monitor Company
FS-8700-104_ControlNet_X30 Manual Table of Contents
TABLE OF CONTENTS
1 ControlNet X30 Description............................................................................................................................ 3
2 Driver Scope of Supply ................................................................................................................................... 3
2.1 Supplied by FieldServer Technologies for this driver ..................................................................................... 3
2.2 Additional files Required for the Driver ......................................................................................................... 3
2.3 Provided by the Supplier of 3rd Party Equipment .......................................................................................... 3
2.3.1 Required 3rd Party Software ................................................................................................................... 3
2.3.2 Required 3rd Party Configuration ........................................................................................................... 3
3 Hardware Connections ................................................................................................................................... 4
3.1 Hardware Connection Tips / Hints ................................................................................................................. 4
4 Data Array Parameters ................................................................................................................................... 5
5 Configuring the FieldServer as a ControlNet Server ........................................................................................ 6
5.1 ControlNet Settings ....................................................................................................................................... 6
5.2 Server Side Connection Parameters .............................................................................................................. 7
5.3 Server Side Node Parameters ........................................................................................................................ 7
5.4 Server Side Map Descriptor Parameters ........................................................................................................ 7
5.4.1 FieldServer Specific Map Descriptor Parameters ................................................................................... 7
5.4.2 Driver Related Map Descriptor Parameters ........................................................................................... 8
5.4.3 Map Descriptor Example. ....................................................................................................................... 9
Appendix A. Useful Features ................................................................................................................................ 10
Appendix A.1. ControlNet X30 LED indicators ......................................................................................................... 10
Appendix B. Vendor Information ......................................................................................................................... 11
Appendix B.1. Using RSNetWorx Version 1.06 with PLC-5 scanner ......................................................................... 11
Appendix B.2. Using RSLogix 5000 for network configuration ................................................................................ 11
Appendix C. Reference ......................................................................................................................................... 13
Appendix C.1. Setting the FieldServer’s ControlNet MAC ID ................................................................................... 13
Appendix C.2. Using the Network Access Port ........................................................................................................ 13
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 3 of 13
FieldServer Mode
Nodes
Comments
Server
1
The FieldServer can only emulate one ControlNet Slave station
FieldServer Technologies PART #
Description
X30-ControlNet
Anybus ControlNet Card
Filename
Comments
Config.csv1
Template loaded if no custom configuration ordered, otherwise Custom configuration loaded.
ControlNet eds file
Required for working with Rockwell’s RSNetworx Tool. Supplied with the FieldServer and also
available via the following link: http://www.fieldserver.com/techsupport/utility/utility.php
1 CONTROLNET X30 DESCRIPTION
The FieldServer ControlNet X30 driver can be used to emulate a single slave station on a ControlNet network. ControlNet scanners can open a connection of up to 450 Bytes in each direction to the FieldServer. Data transfers are via Scheduled Communication and therefore the FieldServer has to be scheduled on the ControlNet network using a Network Configuration Tool such as RSNetWorx or RSLogix. The minimum supported network update time (NUT) is 5 ms. Connection to the ControlNet network is via two standard BNC connector ports. The connection may be to either one or both of the ControlNet ports. A connection to both ports provides dual redundant operation. A Network Access Port (NAP) is also provided for the temporary connection of a Network Configuration Tool.
Max Nodes Supported
2 DRIVER SCOPE OF SUP PLY
2.1 Sup plied by Fiel dSer v e r Techno lo gies for this driver
2.2 Additional files Required for the Driver
2.3 Provide d by the Supplier of 3
2.3.1 Required 3
RSNetWorx, RSLogix or another Network Scheduling Tool.
2.3.2 Required 3
rd
Party So ftware
rd
Party Co nfigurat ion
rd
Party Eq uipm e nt
Connection to a properly terminated ControlNet network.
1
Always Loaded By FieldServer Technologies
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 4 of 13
3 HARDWARE CONNECTIONS
The FieldServer is connected to the ControlNet network as shown in the connection drawing below.
3.1 Hardware Connection Tips / Hints
Use the recommended network cable and terminators as specified by the ControlNet network organization and/or the manufacturer of your network equipment.
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 5 of 13
Section Title
Data_Arrays
Column Title
Function
Legal Values
Data_Array_Name
Provide name for Data Array
Up to 15 alphanumeric characters
Data_Array_Format
Provide data format. Each Data Array can only take on one format.
FLOAT, BIT, UInt16, SInt16, Byte.
Data_Array_Length
Number of Data Objects. Must be larger than the data storage area required by the Map Descriptors for the data being placed in this array.
1-10, 000 // Data Arrays
Data_Arrays
Data_Array_Name
, Data_Array_Format
, Data_Array_Length
DA_AI_01
, UInt16
, 200
DA_AO_01
, UInt16
, 200
DA_DI_01
, Bit
, 200
DA_DO_01
, Bit
, 200
4 DATA ARRAY PARAMETERS
Data Arrays are “protocol neutral” data buffers for storage of data to be passed between protocols. It is necessary
to declare the data format of each of the Data Arrays to facilitate correct storage of the relevant data.
Example
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 6 of 13
Section Title
FieldServer
Column Title
Function
Legal Values
System_Station_Address*
ControlNet MAC ID of the FieldServer
1-99
// FieldServer
FieldServer
Title
, System_Station_Address
CN_Test
. 5
5 CONFIGURING THE FIELDSERVER AS A CONTROL NET SERVER
For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” files dupplied with the FieldServer).
This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a ControlNet Client/Scanner.
The configuration file tells the FieldServer about its interfaces and the routing of data required. In order to enable the FieldServer for ControlNet communications, the driver independent FieldServer buffers need to be declared in
the “Data Arrays” section, the FieldServer virtual node(s) needs to be declared in the “Server Side Nodes” section, and the data to be provided to the clients needs to be mapped in the “Server Side Map Descriptors” section.
Details on how to do this can be found below.
Note that in the tables, * indicates an optional parameter, with the bold legal value being the default.
5.1 Contro lNet Settings
Note:
The ControlNet MAC ID can also be set via the two rotary switches on the side of the FieldServer. These switches should be set to zero or to the same value as System_Station_Address in the configuration file. Alternatively the System_Station_Address parameter should be eliminated from the configuration file. Failing to do so, will cause a warning LED to flash although the MAC ID from the configuration file will still be used.
Example
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 7 of 13
Section Title
Connections
Column Title
Function
Legal Values
Adapter
Adapter Name
ControlNet
// Server Side Connections
Connections
Adapter
ControlNet
Section Title
Nodes
Column Title
Function
Legal Values
Node_Name
Provide name for node
Up to 32 alphanumeric characters
Protocol
Specify protocol used
X30_CNet_Slave
// Server Side Nodes
Nodes
Node_Name
, Protocol
CN5
, X30_CNet_Slave
Column Title
Function
Legal Values
Map_Descriptor_Name
Name of this Map Descriptor
Up to 32 alphanumeric characters
Data_Array_Name
Name of Data Array where data is to be stored in the FieldServer
One of the Data Array names from Section 4
Data_Array_Offset
Starting location in Data Array
0 to (Data_Array_Length -1) as specified in Section 4
Function
Function of Server Map Descriptor
RDBC -Reads data from the local input buffer WRBC -Writes data to the local output buffer
5.2 Serv e r Side Connection Parameters
Example
5.3 Serv e r Side Node P arameters
Example
5.4 Serv e r Side Map Descriptor Parameters
5.4.1 Fie ld Server Specific Map Descriptor Parameters
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 8 of 13
Column Title
Function
Legal Values
Node_Name
Name of Node
One of the node names specified in Section
5.3
CNT_Data_Type
Data Type of local buffer
Byte, Word, Dword, Bool
Address
Byte offset into local buffer
RDBC: 0 – 449 WRBC: 4 – 453
Length
Number of CNT_Data_Type items in local buffer
Byte: 1 – 450 Word: 1 – 225 Dword: 1 – 112 Bool: 1 – 3600
5.4.2 Driver Relate d Map D escriptor Parameters
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 9 of 13
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
5. 4.3 Map D escr ipt o r Ex ampl e.
// Server Side Map Descriptors
Map_Descriptorss
Map_Descriptor_Name
, Data_Array_Name
, Data_Array_Offset
, Function
, Node_Name
, CNT_Data_Type
, Address
, Length
, Scan_Interval
Get_Data
, Input_Data
, 0
, Rdbc
, CN5
, WORD
, 0
, 225
, 1s
Put_Data
, Output_Data
, 0.
, Wrbc
, CN5
, WORD
, 4
, 225
, 1s
Note that each address refers to an individual local input and output buffer. Each buffer can contain up to 450 bytes.
Read function map descriptor gets data from the ControlNet network and stores it in the Input_Data data array.
Write function map descriptor puts data from the Output_Data data array onto the ControlNet network.
Note the start address for the output buffer is
4. Addresses 0-3 are not available.
FS-8700-104_ControlNet_X30 Manual Page 10 of 13
Color
Frequency
Description
Green
Flashing
Module is waiting for initialisation
Green
Steady on
Module is initialised
Red
Flashing
Minor fault, MacID has been changed after initialisation, etc.
Red
Steady on
Major fault, module must be restarted
Color
Frequency
Description
Red/Green
-
See Channel LEDs below
Color
Frequency
Description
Red/Green
-
See Channel LEDs below
Color
Frequency
Description
Green
Steady on
A connection is opened against the ControlNet module
Off - No connection is opened
Channel LEDs
Description
A and B, steady off
Module is not initialised
A and B, steady red
Faulted unit, must be restarted or repaired
A and B, alternating red/green
Selftest of bus controller
A and B, flashing red
Incorrect node configuration, duplicate MacID, etc.
A or B, steady off
Channel is disabled, depending on network configuration
A or B, steady green
Normal operation of channel
A or B, flashing green
Temporary errors (node will self correct) or node is not configured to go online
A or B, flashing red
Media fault or no other nodes on the network
A or B, flashing red/green
Incorrect network configuration
Appendix A. Useful Features
Appendix A.1. ControlNet X30 LED indicators
LED 1 – Module status
LED 2 – LED Channel A
LED 3 – LED Channel B
LED 4 – Module Owned
Channel LEDs
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 11 of 13
Name:
(choose a unique name for this module)
Description:
(self-explanatory and optional)
Comm Format:
Select ‘Data - INT’
Node:
Select the ControlNet node number for this device
Input Assembly Instance
100
Size
1-225
Output Assembly Instance:
150
Size:
Varies with how the module is initialized
Configuration Assembly Instance:
1
Size:
0
Appendix B. Vendor Information
Appendix B.1. Using RSNetWorx Version 1.06 with PLC-5 scanner
The Anybus ControlNet module is not supported for versions earlier than 1.06.
Ensure all nodes are physically connected and start RSNetworx. Go online (check the Go online box) - all connected nodes should appear on the screen. Right click on the PLC5 node and choose ControlNet configuration. The program now launches the Map Editing
Tool used to set up data mapping in the PLC-5 processor.
Right click on the line that contains the Anybus ControlNet module (in the current version of RSNetworx
displayed as Any-BusDT) and choose Insert device connection.
When the line changes to blue, the connection size in, connection size out and to which address in the PLC the
data shall be mapped should be entered. The data is mapped to the Integer area (N-area). For example, 50 bytes in each direction can be mapped so now 25 words in and 25 words out can be chosen.
Save the configuration, switch the PLC key to run and the data is transferred to/from the PLC data table at the
specified address.
Appendix B.2. Using RSLogix 5000 for network configuration
RSLogix is a programming and configuration tool from Rockwell automation. The information included in this section is based on an entry in the Rockwell Automation Support Library and can be accessed at:
www5.software.rockwell.com/support/knowbase.nsf/9dc47c2a86607f2d86256365001169f5/bb01b77898478eca8 52568ef005e0b52?OpenDocument
RSLogix 5000 Version 2.25 and higher versions have a generic profile called CONTROLNET-MODULE which is applicable to devices that connect directly to ControlNet, such as the 1203-CN1 communications card with a Rockwell drive or a Schneider Momentum I/O device. The Anybus ControlNet card also uses this profile. All Anybus ControlNet-enabled I/O will use the same assembly instance numbers, but the data size will change depending on the application and must be relayed to the end user. The ControlNet module does not use configuration data so the length should be left at zero, though a non-zero number nust be entered for the assembly instance. The following list provides information on the settings for the CONTROLNET-MODULE profile with AnyBus-S enabled devices.
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 12 of 13
Notes:
1. The ControlNet module uses a ControlNet 32-bit run/idle header, so the actual data from the module will
always start with word 2 (the third word) of the data. The first 2 words, at 16 bits each, are the ControlNet run/idle header. To mask off the run/idle header for clarity, create a user defined type with 2 members ­HEADER, type DINT; and DATA, type INT with ‘input assembly size - 2’. Copy the data from the actual input tag to a tag of this structure, and then reference the structure's DATA member using the element numbers in your documentation.
2. There will always be a configuration tag of type AB:ControlNet_MODULE:C:0 created for this module, which
has one member called Data, of type SINT[400]. This SINT[400] tag is created regardless of the configuration size, which can range from 0 to 400 bytes (SINTs). Since a data size of zero is specified, no data will be sent to the module.
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
FS-8700-104_ControlNet_X30 Manual Page 13 of 13
Appendix C. Reference
Appendix C.1. Setting the FieldServer’s ControlNet MAC ID
The MAC ID can be set in the FieldServer’s CSV file using the System_Station_Address, (refer to Section 5.1), or it can be set with the two rotary switches as indicated on the connection diagram. The left switch selects the left decimal digit and the right switch the right decimal digit of the MAC ID.
Note that the software setting with the System_Station_Address overrides the hardware setting with the rotary switches. Set the rotary switches to zero or to the same value as in the System_Station_Address to prevent the warning LED from flashing. A mismatch will still result in the software setting being used.
Appendix C.2. Using the Network Access Port
The Network Access Port (NAP) should only be used temporarily to connect a network configuration tool. It must not be used to connect to the main ControlNet network.
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com