Fieldpiece SRS2C User Manual

Features
• Wireless communication between the platform and remote control.
• The remote stores in the body of the platform for convenient carrying.
• Solid aluminum platform with rubber corners means your scale is rugged enough for the field.
• Diamond plate style rubber pad keeps cylinders from sliding around the platform.
• Easy synchronization between the platform and the remote.
• Highly accurate weight sensor.
• Magnetic hat on the remote allows for convenient display location and keeps your hands free.
• Zero (tare) the scale from the remote.
• Remote control remembers the last zero point, even after powering on and off (you won’t lose your calibration even if the scale turns off).
• Bright backlight allows you to read the remote display in any lighting.
• Auto-power off conserves battery life.
• Battery life for both the platform and remote con­trol are visible at all times.
• Wireless signal strength indicator.
• The platform automatically goes into standby when the remote is turned off.
• Long battery life.
Safety
This instrument complies with the requirements of
the following:
FCC Rule Part: 15C
CE: EN300 220
C-Tick
WIRELESS REFRIGERANT SCALE: SRS2C
OPERATOR’S MANUAL
Introduction
The SRS2C is a rugged wireless scale designed specifically for weighing refrigerant cylinders. The wireless remote control is securely stored inside the back of the rugged scale platform. The remote has a bright blue backlight. The remote can be hung by the magnetic hat for easy, hands-free measuring. The platform is made of solid aluminum with rubber cor­ners to protect against the hazards of daily use.
SRS2C Quickstart
OPERATION:
1. Turn on the remote. The platform will turn on
automatically if synchronized and in stand-by
mode.
2. Zero (tare) the scale by holding the ZERO button
on the remote for one second.
3. Press the UNITS button on the remote to select
pounds or kilograms.
4. Read weight directly on the remote’s display.
SYNCHRONIZATION:
If “no Sig” or “CH USEd” is displayed when the remote is powered on, you need to SYNC the remote to your platform.
1. Check that the platform is powered on.
2. Hold the SYNC button on the remote until search
pattern appears.
3. During the search, hold the SYNC button on the
platform until green SYNC LED blinks.
4. If the sync is successful, the SYNC LED will go
solid and a reading will be shown on the display.
PRESS FOR 1 SECOND
AUTO-OFF
SRS2
Wireless Refrigerant Scale
ZERO
SYNC
UNITS
ON/OFF
PRESS FOR 1 SECOND
Wireless Remote
Platform
Opman SRS2C v14
APO: Auto Power Off turns the wireless display off
after 30 minutes. To disable APO, hold the back­light button and then press the ON/OFF button.
Battery life remaining for remote control.
Battery life remaining for the scale platform.
Wireless signal strength between remote and platform.
Major unit reading, in pounds (Lb) or kilograms (Kg).
Minor unit reading, in ounces (oz) or grams (g).
Combine with major unit for total weight. For example: if the upper display shows 14 Lb and the lower display shows 11.50 oz, the total weight is 14 Lbs and 11.50 oz.
Tech Tips for the Field
Respect the Environment
Always use low-loss hose fittings to minimize
harmful refrigerant gases entering the atmosphere.
Hoses Affect Weight
There are two ways to handle this issue:
EASY WAY Connect the hoses to the system before zeroing the scale. Once the system is stable, log the weight displayed before disconnecting from the system.
HARD WAY Zero the scale without hoses connected. Then, connect hoses to the system, and add or recover refrigerant. Disconnect the hoses from the system and the tank. Now the display will show the weight of the added or recovered refrigerant.
G-value compensation
The Earth’s gravitational strength varies depend­ing on your location on the Earth’s surface. This can affect the accuracy of your scale readings.
In order to get the most accurate readings possible you may want to adjust the g-value of your SRS2C.
In order to adjust the g-value of your SRS2C follow the steps below:
1. Hold the UNITS button while powering on the
SRS2C display. This will take you into the g-value
set up. “G-St” will display momentarliy followed by
your SRS2C’s current g-value.
2. Press the UNITS button to scroll through 9
default g-values and a 10th custom input. To
input a custom value press the UNITS button until
“G-St” is shown on the display. Then use the
BACKLIGHT and SYNC buttons to increase or
decrease the g-value.
3. When you have selected the appropriate g-value
for your area, press the ZERO button to exit.
* Default G-value setting.
G-Values
1.) Los Angeles
9.796*
2.) Taipei
9.790
3.) Mexico City
9.779
4.) Kolkata
9.788
5.) Rio De Janeiro
9.788
6.) Sydney
9.797
7.) Tokyo
9.798
8.) Brussels
9.811
9.) Chicago
9.803
10.) Custom input
9.---
SPECIFICATIONS
Specifications good in ambient conditions of 73°F
±9°
F (23°C ±5°C), <75% relative humidity.
Overrange: "OL" mark indication. Auto power off: 30 minutes. Operating environment: 32°F (0°C) to 122°F
(50°C) at <75% R.H.
Storage temperature: -4°F (-20°C) to 140°F
(60°C), 0 to 80% R.H. with battery removed.
Accuracy:
±0.03%rdg + 0.25oz (10g) 0 to 66lbs (0 to 30kg) ±0.05%rdg + 0.25oz (10g) 66 to 254lbs (30 to 115kg)
Resolution: 0.25 oz or 10g Temperature Coefficient: 0.1×(specified accuracy)
per °F.
Wireless Range: 33ft (10 meters) Maximum load: 254 lbs (115kg) Power: Remote: Single standard 9-volt battery,
NEDA 1604, JIS 006P, IEC 6F22. Platform: 6 x AA batteries
Battery life:
Remote: 80 hrs continuous use typical alkaline. Platform: 100 hrs continuous use typical alkaline.
Weight (platform + remote control): 7.1lbs (3.2kg)
Maintenance
Clean the exterior with clean dry cloth. Do not use liquids.
Battery replacement: Separate battery indicators for the remote and the platform are on the display.
Replace the remote’s battery with a NEDA type 1604 9V battery. The scale platform will also indicate low battery by the illumination of the LOW-BATT LED. Replace the platform batteries with 6 AA batter­ies.
Obtaining Service
Call Fieldpiece Instruments for warranty service or out of warranty pricing. Send check or money order for the amount quoted. Send the meter freight pre­paid to Fieldpiece Instruments. Send proof of date and location of purchase for in-warranty service. The scale will be repaired or replaced, at the option of Fieldpiece, and returned via least cost transportation.
Limited Warranty
This scale is warranted against defects in material or workmanship for one year from date of purchase. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect.
This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument.
Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential dam­ages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclu­sions may not apply to you.
www.fieldpiece.com
More from Fieldpiece
The SRS2C wireless refrigerant scale is designed for HVAC/R technicians. Here are some other standalone products from Fieldpiece Instruments.
SRH2 Diagnostic Psychrometer
SC77 All-in-one Expandable Clamp Meter
SSX34 Superheat and Subcooling for A/C and Refrigeration
T2
T2
T2
FF
/O
T2
SRL2 Infrared Refrigerant Leak Detector
ANC3 Briefcase Style Carrying Case
ATC1 K-type Thermocouple Pipe Clamp
TYPE
TEMP.
AUTO-OFF BATTERY
ON/OFF
PRESS FOR 1 SECOND
Temp Cal
ATM
UNIT
NTC
T/C
SENSITIVITY
PEAK
K
SH
SC
T2
T2
CHECK
Diagnostic Psychrometer
°C °F
BATTERY CHECK
T2
RH/DP/WB/DB
AUTO-OFF
MAX/MIN/H
ENTER
ON/OFF
T2ONT2
TSH/TEET/NORM
Calculates Target SH and Target Evap Exit
T/C
Temperature
Cal
SENSOR
T2
PRESS FOR
1 SECOND
ON/OFF
OUTPUT
T2
T2
T2
H
M
L
L/M/H
MUTE
BATTERY CHECK
Infrared Refrigerant Leak Detector
ON/OFF
SRL2
LOW-BATT
PEAK
ON/OFF
PRESS FOR
1 SECOND
T2
T2
APO HOLD n m m F AC DC
m A K M Ω
m V V
HOLD
µ
400
DISCONNECT TESTLEADS
SC77
NCV