O
F
F
NCV
VAC
VDC
AAC
Hz
SEL
HOLD
INRUSH
Fieldpiece
SC57
SC57
O
F
F
WIRELESS ENABLED
SEL
HOLD
HOLD
MAX
MIN
SYNC
MAX
MIN
O
F
F
M
FD
NCV
VAC
VDC
AAC
Hz
Hz
%
°C
SC56
SEL
HOLD
INRUSH
O
F
F
M
FD
NCV
VAC
VDC
AAC
Hz
Hz
%
°C
SC56
SEL
HOLD
INRUSH
O
F
F
SEL
HOLD
HOLD
MAX
MIN
SYNC
MAX
MIN
SC57
SC57
O
F
F
WIRELESS ENABLED
SEL
HOLD
HOLD
MAX
MIN
SYNC
MAX
MIN
SC57
SC57
O
F
F
SEL
HOLD
HOLD
MAX
MIN
SYNC
MAX
MIN
O
F
F
NCV
VAC
VDC
AAC
Hz
SEL
HOLD
INRUSH
SEL
HOLD
HOLD
MAX
MIN
SYNC
MAX
MIN
O
F
F
NCV
VAC
VDC
AAC
Hz
SEL
HOLD
INRUSH
SC54
AUTO OFFTRUE RMS
CAT III
600V
TEMP
K-TYPE
30V
MAX
O
F
F
SEL
HOLD
HOLD
MAX
MIN
MAX
MIN
SYNC
MAX
MIN
SC54
O
F
F
SEL
HOLD
HOLD
MAX
MIN
MAX
MIN
SYNC
MAX
MIN
Swivel
Clamp
Meter
OPERATOR'S
MANUAL
Model SC54
01
Specifications
Display: 10000 count display with backlight
Overrange: (OL) or (-OL) is displayed
Measurement rate: 2 times per second, nominal
Zero: Automatic
Operating environment: 32°F to 122°F (0°C to 50°C) at <70%
relative humidity
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
(with battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coecient: 0.1 x (specied accuracy) per °C [0°C to
18°C (32°F to 64°F), 28°C to 50° C(82°F to 122°F)]
APO (Auto Power O): Approx. 30 minutes
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life: 100 hours typical alkaline
Low battery indication: Battery icon will be empty ( ). "batt"
displays along with a continuous beep when the battery voltage
drops below the operating level. Meter shuts o in 5 seconds.
Dimensions: 258.3mm(H) x 71.2mm(W) x 42.7mm(D)
Weight: Approx. 278g including battery
Altitude: 6562 feet (2000m)
Overload protection: 600VDC or 600VAC rms unless otherwise
stated in the individual test sections.
Test leads: Shall use UL listed test leads complied UL61010-031
rated CATIII 600V or above.
06
Quick Start
1. For electrical testing, connect test leads to
"COM" and "+" jacks. For temperature testing,
remove test leads and slide TEMP switch to
the right.
2. Rotate the dial to your desired function. Press
SEL to cycle through the parameters within
the switch position.
3. Connect to test points and read measurement
on display.
Certifications
UL 61010-1, Second Edition
IEC/EN61010-1
IEC/EN61010-2-032
EMC EN61326-1
C-Tick (N22675)
WEEE
CATIII 600V, class II and pollution degree 2
indoor use comply with CE, RoHS compliant.
02
Functions
Voltage AC (VAC) (50Hz-400Hz)
Test power lines (120, 220, 480), test 24V going to controls, and
test for transformer failure.
Ranges: 0 to 600V Resolution: 0.1V
Accuracy: ±(1.0% + 5 dgts) 50-100Hz
±(6%+5 dgts) 100-400Hz
True RMS: Yes Crest factor: ≤ 3
Input impedance: 1MΩ
Voltage DC (VDC)
Select VDC to measure DC voltage.
Ranges: 0 to 600V
Accuracy: ±(1.0% + 5 dgts) on 600V range
Resolution: 0.1V Input impedance: 1MΩ
MilliVolt DC (mVDC)
Select the mVDC range to display measurements from any
Fieldpiece accessory head. See Modular Expandability section on
reverse page for more details.
Ranges: 1000mV and 10000mV
Accuracy: ±(0.5% + 5 dgts)
Resolution: 0.1mV or 1mV Input impedance: 1MΩ
07
Description
Your SC54 is a swivel clamp meter specially
designed for the HVACR technician. The swivel
on the SC54 allows you to get a good viewing
angle on the display while taking amperage
readings through the clamp, regardless of the
wire orientation. The SC54 has the functions
you want as an HVACR technician.
Get fast manual ranging performance on an
easy to use auto-ranging clamp meter.
The SC54 is compatible with Fieldpiece
accessory heads allowing you to measure many
parameters on the SC54 display.
The bright blue backlight
to use in any lighting condition. True RMS helps
you take more accurate voltage and amperage
readings on variable frequency drives.
The unique temperature circuit allows the
SC54 to get accurate temperature readings
faster when moving from a rooftop to a freezer.
The easily accessible field calibration allows
you to calibrate the temperature on your SC54
without hassle.
03
O
F
08
F
O
F
F
O
F
F
makes it easier
AirVelocity
&Temperature
English
Head
Metric
English Metric
Ft/min M/s
KM/hrMPH
ºF ºC
OFF
AUTOOFF
SELRNG
AAV3
Controls
Display
Battery Life Indicator
O
F
F
Auto Power O Enabled
High Voltage Warning (+30V)
Manual Ranging
Data Hold Mode
Maximum Reading
Minimum Reading
Continuity Test
Frequency Test (hertz)
Resistance Test (ohms)
Capacitance Test (farads)
Micro Unit (10−6, one millionth)
Rotate dial to the function you want to use.
Milli Unit (10−3, one thousandth)
Cycle through parameters or ranges
within a dial position
Press to illuminate backlight for 3 min
Press to freeze maximum or minimum
MAX
MIN
reading
HOLD
Press to freeze the reading
04
MicroAmps DC (µADC)
Microamps for ame rectier diode test on a heater control.
Connect leads between ame sensor probe and control module and
turn heating unit on to read µA measurement. When the ame is on,
there should be a measurable µADC signal, typically under 10µADC.
Compare measurement to manufacture’s specication to determine if
replacement is necessary.
Ranges: 1000µA Resolution: 0.1µA
Accuracy: ±(1.0% + 5 dgts) Voltage burden: 1V
Overload Protection: 600VDC or 600VAC rms
Frequency (Hz) Through Leads
Check variable frequency drives. Check incoming voltages to
ensure they are cycling at 60Hz or desired frequency. Select VAC/Hz
and press SEL button.
Ranges: 20 to 400Hz Resolution: 0.1Hz
Accuracy: ±(0.5% + 5)
Sensitivity: 5V rms on VAC range.
05
O
F
F
O
F
F
Capacitance (MFD)
Capacitors are one of the most failure prone components in
ON
READLOBATT
Average
(16sec)
Real
time
capacitors. Discharge the capacitor and disconnect from power and
resistors between terminals before testing.
LCDX
a HVAC/R system. Set to MFD/Ω/
100
to test motor start and run
Ranges: 0 to 1000µF Resolution: 0.1µF
Accuracy: ±5% + 15 dgts
Overload Protection: 600VDC or 600VAC rms
09
10
O
F
F
Discharge Cap First!
Amps AC (AAC) TrueRMS (50-60Hz)
Test any isolated power line. Select AAC/Hz dial position.
Ranges: 0 to 400AAC Resolution: 0.1A Crest factor: ≤ 3
Accuracy: ±(2.0% + 5dgts) 50-60Hz
Jaw Opening: 1.2in (30 mm) Overload Protection: 400AAC
Frequency (Hz) Through Clamp
Measure frequency without using test leads, just use the clamp.
Turn dial to AAC/Hz and press SEL. Clamp Hz will be displayed.
Range: 20Hz to 400Hz Accuracy: ±(0.5% + 5)
Minimum current range: > 5AAC at 20 to 100Hz, >10AAC at 100
to 400Hz Resolution: 0.1Hz Overload Protection: 400AAC
Resistance (Ω)
Used for “ohming out” a motor. 0.1Ω resolution is necessary to
test the resistance between the motor poles because the values are
typically very low. Select MFD/Ω/
Ranges: 0 to 1000Ω, 1000Ω to 9999Ω
Resolution: 0.1Ω Overload Protection: 600VDC/VAC rms
Accuracy: ±(1.5% + 5)
Continuity (
Use the continuity feature to test if a circuit is open or closed. Use
this feature to check fuses as well. A steady “beep” and green LED
indicate the circuit is good. Select MFD/Ω/
Range: 1000Ω Resolution: 0.1Ω Response time: 100ms
Audible beep: <30Ω Overload Protection: 600VDC/VACrms
and press SEL button once.
)
and press SEL twice.
Non Contact Voltage (NCV)
Use the non contact voltage (NCV) feature to test if a wire is hot
or not. Always test on a known live source before using. A red LED
blinks and beeping sound is emitted at voltages >24VAC
AC Voltage Detection Range: 24VAC to 600VAC (50-60Hz)
11
12
O
F
F
O
F
F
O
F
F
SELRNG
SELRNG
Temperature (°F/°C)
Plug any K-type thermocouple directly into the meter to measure
temperature. Cold junction is located inside the meter and allows for
extremely accurate measurements even in rapidly changing ambient
temperatures (going from rooftop to freezer). No adapter is required.
See Temp Calibration section for calibration instructions.
Range: -40°F to 2200°F, (-40°C to 1200°C) Resolution: 0.1°
Accuracy: ±(1°F) 32°F to 120°F, ±(1°C) 0°C to 49°C
±(1%+2°F) 120°F to 750°F, ±(1%+1°C) 49°C to 400°C
±(2%+6°F) -40°F to 32°F, ±(2%+3°C) -40°C to 0°C
±(2%+6°F) 750°F to 2200°F, ±(2%+3°C) 400°C to 1200°C
Sensor type: K-type thermocouple
Overload protection: 30 VDC or 30VAC rms
13
O
F
F
Unplug Leads and Slide
TEMP Switch to the Right
30V
MAX
TEMP
CAT III
600V
AUTO OFFTRUE RMS
K-TYPE
Temp. Calibration
For accuracies of ±1°F,
calibrate to a known
temperature. A glass
of stabilized ice water
is very close to 32°F
(0°C) and is usually very
convenient but any
known temperature can
be used.
1. Select the °F/ °C range.
2. Plug thermocouple to be
calibrated into the K-type jack.
3. Unscrew A and B and remove
the battery cover.
4. Stabilize a large cup of ice
water. Stir the ice with the
water until temperature stays at
32°F (0°C).
5. Immerse the thermocouple
probe and let it stabilize. Keep
stirring to prevent micro-
environments.
6. Use a small screwdriver to
adjust calibration pot C to the
right of the battery as close to
32°F as you would like.
14
Modular
Expandability
Your Swivel Clamp Meter is compatible with
all Fieldpiece Accessory Heads. With Fieldpiece
Accessory Heads, you can measure any
available parameter, and read the measurement
on your meter's display in real-time.
Just set the range to mVDC. Pressing SEL
changes the mV range. Remove the probe tips
of your test leads, and connect your accessory
head (model AAV3 shown).
O
F
F
SELRNG
Visit www.eldpiece.com to see all of the
dierent accessory heads that Fieldpiece oers.
15
AirVelocity
&Temperature
Head
English Metric
Ft/min M/s
ºF ºC
OFF
ON
English
Metric
KM/hrMPH
AUTOOFF
AAV3
LCDX
100
READLOBATT
Average
(16sec)
Real
time
Safety Features
1. Bright LED and beeper warn you when testing
voltages above 30V.
2. Switch to the NCV function (non contact voltage) and point clamp claw towards suspected
voltage source. Monitor the bright LED and
beeper to see if the source is “hot.”
3. Rotate the clamp to the angle that best suits
the situation.
4. Temp switch to prevent leaving thermocouple
plugged in while measuring voltage.
BatteryReplacement
The battery must be replaced when the
battery icon is empty. "bAtt" will display with a
beeping sound. Meter will shut o in 5 seconds.
Disconnect and unplug leads, turn meter o
and remove battery cover.
Safety Information
• Never ground yourself when taking electrical
measurements. Do not touch exposed metal
pipes, outlets, xtures, etc., which might be at
ground potential, while taking measurements.
Keep your body isolated from ground by using dry clothing, rubber shoes, rubber mats,
or any approved insulating material.
• Disconnect the test leads before opening the
case. Inspect the test leads for damage to the
insulation or exposed wire. Replace if suspect.
Keep your ngers behind the nger guards on
the probes while taking measurements.
• When disconnecting from a circuit, disconnect
the “RED” lead rst, then the common “BLACK”
lead. Use one handed testing when possible.
Work with others.
• Turn o power to the circuit under test before
cutting, unsoldering, or breaking the circuit.
• Do not measure resistance (ohms) when circuit is powered. Isolate load by disconnecting
from circuit.
• Disconnect the meter from the circuit before
turning any inductor o, including motors,
transformers, and solenoids. High voltage
transients can damage the meter beyond
repair. Do not use during electrical storms.
• Do not apply more than rated voltages between input and ground.
• Isolate capacitors from system and discharge
them safely before testing.
All voltage tests: All voltage ranges will
withstand up to 600V. Do not apply more than
600VDC or AC rms.
Symbols used:
Caution, risk of electric shock
Caution, refer to manual.
Ground
Double insulation
WARNINGS
DISCONNECT AND UNPLUG TEST LEADS before opening case.
TEST NCV FUNCTION ON KNOWN LIVE WIRE before using.
DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the
thermocouple or the jacks when the rotary dial is on °F. (Use
only k-type thermocouples)
REMOVE THE THERMOCOUPLE when taking voltage measurements.
DISCONNECT TEST LEADS when measuring temperature.
DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on
microamps. Even low voltages can cause a current overload and
potentially harm the meter.
Maintenance
Clean the exterior with a dry cloth. Do not
use liquid.
Limited Warranty
This meter is warranted against defects in
material or workmanship for one year from
date of purchase. Fieldpiece will replace or
repair the defective unit, at its option, subject
to verication of the defect.
This warranty does not apply to defects
resulting from abuse, neglect, accident,
unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arising from the sale of
a Fieldpiece product, including but not limited
to implied warranties of merchantability and
tness for a particular purpose, are limited to
the above. Fieldpiece shall not be liable for loss
of use of the instrument or other incidental or
consequential damages, expenses, or economic
loss, or for any claim of such damage, expenses,
or economic loss.
State laws vary. The above limitations or
exclusions may not apply to you.
Obtaining Service
Call Fieldpiece Instruments for one-pricefix-all out-of-warranty service pricing. Send
check or money order for the amount quoted.
Send the meter freight prepaid to Fieldpiece
Instruments. Send proof of date and location
of purchase for in-warranty service. The meter
will be repaired or replaced, at the option
of Fieldpiece, and returned via least cost
transportation.
www.fieldpiece.com
© Fieldpiece Instruments, Inc 2012; v04
16
17
18
19
20