SPECIFICATIONS
Display: 3¾ digit liquid crystal display (LCD) with a maxi-
mum reading of 3999.
Range : Manual ranging mode (SC44 & SC45), hold
button for 2 seconds to return to autoranging mode.
Overrange: "OL" or “-OL” mark indication.
Auto power off: 10 minutes.
Operating environment: 32°F to 122°F at <70% R.H.
Storage temperature: -4°F to 140°F, @ <80% R.H. with
batteries removed.
Accuracy: Specifications good in ambient conditions of
74°F ±8°F, <75% relative humidity.
Temperature coefficient: 0.1×(specified accuracy) per °F.
(32°F to 66°F, 82 °F to 122°F).
Altitude: 6561.7 feet (2000m).
Power: Two AAA 1.5V batteries.
Battery life: 400 hours typical with alkaline (SC44),
300 hours typical with alkaline (SC45),
200 hours typical with alkaline (SC46).
Accessories: One pair test leads, (2) 1.5V AAA batteries
(installed), carrying case and operating instructions.
Safety: Designed to meet IEC61010-1 (EN61010-1) and
IEC61010-2-032 (EN61010-2-032), CATIII 300V, class II
and pollution degree 2 indoor use comply with CE,
UL61010B-1, UL61010B-2-032.
Temperature (SC45 and SC46)
Range: -30°F ~ 400°F
Resolution: 0.1°F
Accuracy:
±(1°F) 32°F ~ 120°F,
±(1% + 1.5°F) -4°F ~400°F,
±(2% + 4°F) -30°F ~ -4°F,
Sensor type: K-type thermocouple
Capacitance (SC45 and SC46)
Range: 4μF, 40μF, 400μF, 4mF
4.000mF = 4000μF
Resolution: 1.0nF
Accuracy: ±(3% rdg + 10 dgts) on 4μF
±(3% rdg + 5 dgts) on 40μF to 400μF
±(5% rdg + 20 dgts) on 4mF (4000μF)
Minimum input range: >100nF
Safety: “dsc” symbol on LCD indicates that the
capacitor must be discharged before testing.
DC volts
Ranges: 400mV (except SC46), 4V, 40V, 400V,
600V
Resolution: 0.1mV (1mV for SC46)
Accuracy: ±(0.5% rdg + 2 dgt)
Input impedance:
400mV > 100MΩ
4V = 10MΩ
40V~600V = 9.1MΩ
Transient protection: 6kV for 10μ sec
AC volts (50Hz - 500Hz)
True RMS: SC46 only, Crest factor: ≤3
Ranges: 4V, 40V, 400V, 600V
Resolution: 1mV
Accuracy(SC44, SC45): ±(1.2% rdg + 5 dgts),
±(1.5% rdg + 5 dgts) on 600V range
Accuracy(SC46): ±(1.2% rdg + 8 dgts),
±(1.5% rdg + 8 dgts) on 600V range
Input impedance:
4V = 10MΩ
40V~600V = 9.1MΩ
Resistance
Ranges: 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
SC45 and SC46 only have a 400
Ω
range.
Resolution: 0.1Ω (1Ω for SC45, SC46)
Accuracy:
±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 4 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
Open circuit volts: -0.45VDC typical, (-1.2VDC on
400Ω range)
AC Current (50Hz - 60Hz)
True RMS: SC46 only, Crest factor: ≤3
Ranges: 40A, 400A, Resolution: 0.01A
Accuracy(SC44, SC45): ±(2.0% rdg + 6 dgts)
Accuracy(SC46): ±(2.0% rdg + 10 dgts)
Continuity
Audible indication: Less than 25Ω
Response time: 500ms
Diode Test
Test current: 1.2mA (appoximate)
Accuracy: ±(3.0% rdg + 3 dgts)
Resolution: 10mV
Audible indication: Less than 0.25V
Open circuit volts: 3.0VDC typical
Voltage
Amps AC Through Clamp
Resistance
Capacitance
.