Fieldpiece
O
F
F
M
FD
NCV
VAC
VDC
AAC
Hz
Hz
%
°C
SC56
SEL
HOLD
INRUSH
O
F
F
M
FD
NCV
VAC
VDC
AAC
Hz
Hz
%
°C
SC56
SEL
HOLD
INRUSH
O
F
F
FD
NCV
VAC
VDC
AAC
Hz
Hz
SC56
SEL
HOLD
INRUSH
O
F
F
NCV
VAC
VDC
AAC
Hz
SEL
HOLD
INRUSH
O
F
F
NCV
VAC
VDC
AAC
Hz
SC56
SEL
HOLD
INRUSH
NCV
VDC
AAC
Hz
SEL
HOLD
INRUSH
COM
CAT III
600V
Fieldpiece
Select
M/m
SC260
TRUE RMS
V
AC
NCV
A
AC
°F°C
V
DC
MFD
TEMP
AUTO OFF
TYPE K
30V
MAX
M/m
TRUE RMS
VAC
NCV
A
AC
°F°C
V
DC
MFD
Compact
Clamp
Meters
OPERATOR'S
MANUAL
Models SC260
SC240 SC220
01
Quick Start
1. For electrical testing, connect test leads to
"COM" and "+" jacks.
2. Rotate the dial to your desired measurement.
3. Connect to test points and read measurement.
4. For temperature testing, remove test leads,
slide TEMP switch to the right and connect
Type K thermocouple (SC240/SC260 only).
Certifications
UL 61010-1, Third Edition
EN61010-1
EN61010-2-032
EN61010-2-033
EMC EN61326-1
C-Tick (N22675)
WEEE
CATIII 600V, class II and pollution degree 2
indoor use comply with CE, RoHS compliant.
CATIII is for measurements performed in the
building installation.
02
Description
The new SC200 series compact clamp meters
are designed for everyday HVACR service. Their
compant pocketable design makes them easy
to take on any job.
Hang the SC260 to any metallic surface with
its newly designed swivel magnet to keep your
hands free to do more. Test variable frequency
drives more accurately with True RMS and easily
see your measurements in low lighting with the
bright blue blacklight (SC260 only).
Save time with the new Auto Select mode.
Simply set the dial to (
connect your leads. Your meter will automatically
select the appropriate measurement depending
on what it detects. Move from a cold freezer to
a hot rooftop and get accurate temperature
measurements that lesser thermometers cannot
measure properly (SC240/SC260 only).
Test for proper ame rectication micro amp
DC current on heating systems (SC220 only).
All SC200 compact clamp meters are built to
withstand the rigors of HVACR service with high
impact plastic and a display you can read in very
hot or very cold environments.
03
/
/
/MFD) and
Controls
MFD
A
NCV
°F°C
Rotate dial to the function you want to use.
Select a parameter. Ohms/Continuity/
Select
Diode/MFD. °F/°C (SC240/260 only).
Toggle backlight (SC260 only).
Freeze maximum and minimum read-
M/m
ing. Hold for 1 second to clear .
(SC240/SC260 only)
Manually select a range (SC220/240).
Range
Freeze the display.
HOLD
04
AC
VAC
DC
V
Display
Battery Life (replace 9V if blinking)
Auto Power O Enabled
High Voltage Warning (>16VAC/35VDC)
Manual Range (Range) Mode
Maximum Reading
Minimum Reading
Data Hold Mode
Auto Select Mode (
Continuity Test
Diode Test
Resistance Test (ohms)
Capacitance Test (farads)
Nano Unit (10
-9
Micro Unit (10−6, one millionth)
Milli Unit (10−3, one thousandth)
Kilo Unit (103, one thousand)
Mega Unit (106, one million)
05
/
/
, one billionth)
/MFD)
Safety Information
Never ground yourself when taking electrical
measurements. Do not touch exposed metal
pipes, outlets, xtures, etc., which might be
at ground potential, while taking measurements. Keep your body isolated from ground
by using dry clothing, rubber shoes, rubber
mats, or any approved insulating material.
Disconnect the test leads before opening the
case. Inspect the test leads for damage to the
insulation or exposed wire. Replace if suspect.
Keep your ngers behind the nger guards on
the probes while taking measurements.
When disconnecting from a circuit, disconnect
the “RED” lead rst, then the common “BLACK”
lead. Use one handed testing when possible.
Work with others.
Turn o power to the circuit under test before
cutting, unsoldering, or breaking the circuit.
Do not measure resistance (ohms) when circuit
is powered. Isolate load by disconnecting
from circuit.
Disconnect the meter from circuit before turning
any inductor o, including motors, transformers, and solenoids. High voltage transients
can damage the meter beyond repair.
06
Do not use during electrical storms.
Do not apply more than rated voltages between
input and ground.
Isolate capacitors from system and discharge
them safely before testing.
Temperature switch prevents leaving thermo-
couple plugged in while measuring voltage.
When measuring high frequency AC current, do
not exceed the rated 400AAC of the clamp.
Failure to adhere may cause the clamp to heat
up dangerously.
All voltage tests: All voltage ranges will
withstand up to 600V. Do not apply more than
600VDC or AC rms.
Symbols used:
Caution, risk of electric shock
Caution, refer to manual.
Ground
Double insulation
WARNINGS
DISCONNECT AND UNPLUG TEST LEADS before opening case.
TEST NCV FUNCTION ON KNOWN LIVE WIRE before using.
DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the
thermocouple or the jacks when the rotary dial is on °F°C. (Use
only Type K thermocouples)
DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on
microamps. Even low voltages can cause a current overload and
potentially harm the meter.
07
Specifications
Display: 4000 count
Backlight: 5 minute duration with auto-o. Blue color. SC260 only
Overrange: (OL) or (-OL) is displayed
Measurement rate: 3 times per second, nominal
Zero: Automatic
Operating environment: 32°F to 122°F (0°C to 50°C) at <70%
relative humidity
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
(with battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coecient: 0.1 x (specied accuracy) per °C [0°C to
19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)]
APO (Auto Power O): Approx. 30 minutes
Power: 9V, NEDA 1604A, IEC 6LR61 9V alkaline battery
Battery life: 200 hours typical alkaline (SC220/SC240); 150 hours
typical alkaline (SC260)
Low battery indication: Battery icon blinks and "LO.bt" is displayed
when the battery voltage drops below the operating level
Dimensions: 205.5mm(H) x 67.4mm(W) x 45.1mm(D)
Weight: Approx. 265g including battery
Altitude: Up to 6562 ft (2000m)
Overload protection: 600 VDC or 600VAC rms unless otherwise
stated
Test leads: Use UL listed test leads that comply to UL61010-031
rated CATIII 600V or above. Included test leads are gold-plated
and have removeable safety caps.
Please operate the instrument following all instructions
of the operator's manual to avoid impairing the safety
of the product.
08
Functions
Temperature (°F/°C) SC240 and SC260 only
Plug any Type K thermocouple directly into the meter to measure
temperature. Cold junction is located inside the meter and allows for
extremely accurate measurements even in rapidly changing ambient
temperatures (going from rooftop to freezer). No adapter is required.
See Temp Calibration section for calibration instructions.
Range: -30°F to 752°F, (-35°C to 400°C) Resolution: 0.1°
Accuracy: ±(1°F)* 32°F to 120°F, ±(1°C) 0°C to 49°C
±(1%+2°F) 32°F to 392°F, ±(1%+1°C) 0°C to 200°C
±(2%+6°F) -30°F to 32°F, ±(2%+3°C) -35°C to 0°C
±(2%+6°F) 392°F to 752°F, ±(2%+3°C) 200°C to 400°C
Sensor type: Type K thermocouple *After eld calibration
Overload protection: 30 VDC or 30VAC rms
Voltage DC (VDC)
Select VDC and measure DC voltages on circuit boards on more
advanced HVACR systems.
Ranges: 4V, 40V, 400V, 600V Resolution: 0.001V
Accuracy: ±(0.5% + 2)
Input impedance: 10MΩ (4V), 9.1MΩ (40V-600V)
Voltage AC (VAC) (50Hz-500Hz)
Test power lines (120, 220, 480), test 24V going to controls, and
test for transformer failure.
Ranges: 4V, 40V, 400V, 600V Resolution: 0.001V
Accuracy: ±(1.2% + 8)
±(1.5% + 8) on 600V range
True RMS: model SC260 only Crest factor: ≤ 3
Audio/Visual Hi-V indicator: >16VAC/35VDC
Input impedance: 10MΩ (4V), 9.1MΩ (40V-600V)
09
10
NCV
°F°C
NCV
°F°C
°F°C
NCV
MFD
MFD
MFD
AUTO OFF
A
AC
VAC
DC
V
A
AC
VAC
DC
V
A
AC
VAC
DC
V
TYPE K
COM
Unplug Leads and Slide
TEMP Switch to the Right
30V
MAX
Capacitance (MFD) SC240 and SC260 only
A
C
B
TEMP CAL
DO NOT SWITCH FROM J2
Start and run capacitors are one of the most failure prone
components in a HVACR system. Disconnect from power and resistors
between terminals. Discharge capacitor before testing. If dIS.C is
displayed, capacitor is not fully discharged. Set to
/
/
MFD to test capacitance of motor start and run capacitors or press
SELECT three times to manually select MFD.
Ranges: 4nF, 40nF, 400nF, 4µF, 40µF, 400µF, 4mF Resolution: 1pF
Accuracy: ±(3% + 20) 4nF, ±(3% + 5) 40nF to 400µF,
±(5% + 20) 4mF
Auto Select Ranges: 4nF to 400µF, >500pF
Overload Protection: 600VDC or 600VAC rms
Resistance (Ω)
Used for “ohming out” a compressor. 0.01Ω resolution is useful to
test the resistance between the motor poles because the values are
typically very low.
Ranges: 40Ω, 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Resolution: 0.01Ω
Accuracy: ±(1.0% + 15) 40Ω, ±(1.0% + 5) 400Ω to 400kΩ,
±(1.5% + 5) 4MΩ, ±(3.0% + 5) 40MΩ
Auto Select Ranges: 4KΩ to 4MΩ, >400Ω (SC240/SC260 only)
Overload Protection: 600VDC or 600VAC rms
Continuity (
Set to
if a circuit is open or closed or press SELECT once to manully select
continuity. Use this feature to check fuses as well. A steady “beep”
and green LED indicate you have continuity.
Range: 400Ω Resolution: 0.1Ω Response time: 100ms
Audible beep: <30Ω
Overload Protection: 600VDC or 600VAC rms
11
/
/
)
/MFD and measure continuity to test
MFD
A
NCV
°F°C
AC
AC
V
DC
V
/
Diode Test (
Set to
/
and reversed-biased functions. Press SELECT twice to manually select
the diode test. A constant beep and green LED indicate continuity.
Test current: 1.0mA (Approx.) Accuracy: ±(1.5% + 5)
Open circuit volts: 3.2VDC typical
Visual indicator: Green LED Audible beep: <0.03V
Auto Select Threshold: Forward voltage drop <0.8V (SC240/SC260
only)
Overload Protection: 600VDC or 600VAC rms
Non Contact Voltage (NCV)
Use NCV to check for 24VAC from a thermostat or live voltage up
to 600VAC. Always test on a known live source before using. A three
segment graph and RED LED will display the presence of voltage. The
NCV
°F°C
MFD
Discharge Cap First!
A
AC
VAC
DC
V
audible beep increases from intermittent to continuous as intensity of
)
/
/MFD to test diodes for proper forward
°F°C
NCV
°F°C
NCV
MFD
MFD
MicroAmps DC (µADC) SC220 only
Microamps for ame rectier test on a heater control. Connect
A
AC
VAC
DC
V
600V
MAX
30V
A
AC
VAC
DC
V
DC
V
AC
V
S
AC
A
TRUE RM
°F°C
NCV
MFD
Fieldpiece
CAT III
TEMP
COM
AUTO OFF
TYPE K
SC260
m/M
Select
leads between ame sensor probe and control module and turn
heating unit on to read µA measurement. When the ame is on,
there should be a measurable µADC signal, typically under 10µADC.
Compare measurement to manufacturer’s specication to determine
if replacement is necessary.
Ranges: 400µA, 4000µA Resolution: 0.1µA
Accuracy: ±(1.0% + 2) Voltage burden: 1V, 8V on 4000µA
Overload Protection: 600VDC or 600VAC rms
A
AC
µADC
VACNCV
VDC
eld (EF) increases.
AC Voltage Detection Range: 24VAC to 600VAC (50-60Hz)
NCV
°F°C
MFD
Amps AC (AAC)
Test any isolated power line, compressor or capacitor wire. True
RMS on SC260 only.
A
AC
VAC
DC
V
Ranges: 40A, 400A Resolution: 0.01A Crest factor: ≤ 3
Accuracy: ±(2.0% + 10) 50-60Hz Jaw Opening: 1.2in (30 mm)
True RMS: model SC260 only Overload Protection: 400AAC
Note: AAC through the clamp and voltage through the test
leads can be measured simultaneously. However, if only AAC is
measured through the clamp, test leads and thermocouple must
be unplugged from the meter.
NCV
°F°C
MFD
DC
V
AC
V
S
AC
A
AC
VAC
DC
V
A
TRUE RM
MFD
Fieldpiece
600V
CAT III
MAX
30V
TEMP
COM
AUTO OFF
K-TYPE
SC260
m/M
Select
°F°C
NCV
Auto Select Mode
For SC240/260 only. Save time and let your
meter select the appropriate test parameter. Set
the selector switch to
/
/
/MFD and use
your test leads to take the measurement. The
clamp meter will automatically display an ohms,
diode, continuity, or capacitance reading. In
Auto Select mode, the
M/m
and
buttons
Range
are disabled.
12
13
14
15
Temp. Calibration
For accuracies of ±1°F, calibrate to a known
temperature. A glass of stabilized ice water
is very close to 32°F (0°C) and is usually very
convenient but any known temperature can be
used. For SC240/SC260 models only.
1. Select the °F °C range.
2. Plug thermocouple to be
calibrated into the Type K jack.
3. Unscrew A and B and remove
the battery cover.
4. Stabilize a large cup of ice
water. Stir the ice with the
water until temperature stays
at a stable value.
5. Immerse the thermocouple
probe and let it stabilize. Keep
stirring water to prevent micro-
environments.
6. Do not let the thermocouple
come in direct contact with ice.
7. Use a small screwdriver to
Note: J1-J2 switch is for auto-
adjust calibration pot C below
the battery as close to 32°F
(0°C) as you would like.
calibration purposes only. Not
intended for use in the eld.
Safety Features
1. Bright LED and beeper warn when testing voltages >16VAC/35VDC. High Voltage warning.
2. Switch to the NCV function (non contact voltage) and point clamp claw towards suspected
voltage source. Monitor the bright RED LED
and beeper to see if the source is “hot.”
3. Temperature switch prevents the thermocouple plugging in while measuring voltage.
Auto Hold
Press and hold
will beep and HOLD will blink on LCD. After 6
seconds the measurement on screen will freeze
automatically. Press
HOLD
for two seconds. Meter
HOLD
to exit this mode.
Auto Power Off
Auto power o or APO will automatcially turn
o your meter after 30 minutes of inactivty. By
default it is activated and APO will show on the
display. To disable, turn meter o. Hold
(SC240/260) and power on the meter by turning
the selector dial to any range. For SC220, follow
the same procedure but hold
and power on.
Range
M/m
Max/Min SC240 and SC260 only
Record and freeze the maximum and
minimum measurements. Press
freeze the maximum reading. MAX will show on
display. Press
M/m
again to freeze the minimum
reading. MIN will show on display. Press
again to display real-time measurement
with both maximum and minimum readings
recording in the background. MAX MIN will blink
on display. Press and hold
M/m
to exit Max/Min mode.
Max/Min functionality is disabled in Auto
Select mode.
M/m
once to
M/m
for one second
Maintenance
Clean the exterior with a dry cloth. Do not
use liquid.
Limited Warranty
This meter is warranted against defects in
material or workmanship for one year from
date of purchase. Fieldpiece will replace or
repair the defective unit, at its option, subject
to verication of the defect.
This warranty does not apply to defects
resulting from abuse, neglect, accident,
Obtaining Service
Call Fieldpiece Instruments for one-pricefix-all out-of-warranty service pricing. Send
check or money order for the amount quoted.
Send the meter freight prepaid to Fieldpiece
Instruments. Send proof of date and location
of purchase for in-warranty service. The meter
will be repaired or replaced, at the option
of Fieldpiece, and returned via least cost
transportation.
For international customers, warranty for
products purchased outside of the U.S. should
be handled through local distributors.
unauthorized repair, alteration, or unreasonable
use of the instrument.
Battery Replacement
When the battery is low, the battery icon will
empty and blink for 30 seconds. “LO.bt” will
display and meter will power o.
Turn dial to OFF position, disconnect test
leads and remove the battery cover. Remove
old battery and replace with a standard 9V
battery only.
Any implied warranties arising from the sale of
a Fieldpiece product, including but not limited
to implied warranties of merchantability and
tness for a particular purpose, are limited to
the above. Fieldpiece shall not be liable for loss
of use of the instrument or other incidental or
consequential damages, expenses, or economic
loss, or for any claim of such damage, expenses,
or economic loss.