Fieldpiece Fieldpiece SDMN5 Manual

Page 1
General
Accuracy: Stated accuracy at 0 to 50°C (32 to
122°F): ±1.5% FS
Battery: Single standard 9-volt battery, NEDA
1604, JIS 006P, IEC 6F22.
Battery Life: 200 hours with low battery indicator
on display.
32ºF (0°C) to 122ºF (50°C)
Compatible Media: Dry, non-corrosive gases Overrange: “OL” or “-OL” is displayed. Auto-Off power: 15 minutes Low Battery: symbol is displayed. Dimensions: 180mm(~7 1/16”)(H) x 60mm(~2
3/8”)(W) x 30mm(~1 3/16”)(D)
Weight: approximately 195g including battery
Pressure
Pressure Ports: tube connectors for 5mm (~3/16
inch) I.D. flexible tubing
Units of Measure: inWC, mmWC, mbar, PSI Resolution: 0.01 inch WC Accuracy/Ranges:
inWC: ±0.02 on 0.00 to ±2.00
±1.5% FS on 2.00 to ±60.0
mmWC: ±0.5 on 0.00 to ±51.0
±1.5% FS on 51.0 to ±1500
mbar: ±0.05 on 0.00 to ±5.00
±1.5% FS on 5.00 to ±150.0
psi: ±0.001 on 0.000 to ±0.07
±1.5% FS on 0.07 to ±2.000
RMA316 Manometer Adapter
Used for 5/16" pressure outlet ports.
1. Shut off main gas supply to furnace.
2. Move the gas valve switch to "OFF" position.
3. Use a 3/32" hex wrench to loosen the outlet pressure tap screw. Rotate screw counter­clockwise one revolution to open.
4. Connect the SDMN5 tubing to the smaller (3/16") end of the adapter and the other (5/16") end of the adapter into the of the adapter tube.
5. Slide the 5/16" adapter tube over the outlet pressure boss (port) to seal. Overlap the pres­sure boss by at least 3/8" to prevent leakage.
Warranty
The product is warranted to the original purchas­er against defects in material or workmanship for a period of one (1) year from the date of purchase. During the warranty period, Fieldpiece Instruments will, at its option, replace or repair the defective unit.
This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranty arising out of the sale of Fieldpiece's products including but not limited to implied warranties of merchantability, and fitness for purpose, are limited to the above. Fieldpiece shall not be liable for incidental or consequential dam­ages.
Service
Return any defective SDMN5 to Fieldpiece for warranty service along with proof of purchase. Contact Fieldpiece for out of warranty repair charges.
Dual Port Differential Manometer Model: SDMN5
OPERATOR’S MANUAL
Description
The SDMN5 is a portable standalone dual port manometer. The SDMN5 is capable of taking gas pressure as well as static pressure. The SDMN5 comes in a rugged rubber boot. The SDMN5 also has a zero adjust and a hold button to hold the cur­rently displayed reading. The auto-power-off func­tion conserves battery life, but can be disabled if desired.
The SDMN5 will allow you to take gas pressure up to ±60” (152cm) of WC. The SDMN5 will take dif­ferential pressure readings and display the differ­ence between P1 and P2 at all times in the lower right corner of the LCD. The SDMN5 also has four different measurement scales including inches of water column, millimeters of water column, mBar and PSI. Static pressure is possible with the reso­lution to 0.01” of WC (0.1mmWC). Special purpose static pressure instruments are on the market with better accuracy and temperature compensation but they typically cost many times more than the SDMN5.
Operation
1. Zero SDMN5 by pressing the ZERO just before taking the pressure readings, while at ambient pressure. This will zero both P1 and P2. For measurements less than 2inWC, take reading within 1 minute after zeroing for best accuracy.
2. Connect a single hose to get the gauge pres­sure relative to the ambient or ZERO pressure.
3. Connect both hoses if you want to see relative pressure, P1 minus P2.
4. By pressing the P1 / P2 button you can change between displaying P1 or P2, P1 - P2 is con­stantly displayed in the lower right of the LCD.
5. Pressing the unit button makes it possible to switch between the four measurement scales of inches of water column (inWC), millimeters of water column (mmWC), mBar, and PSI. The scale being viewed is displayed on the right side of the LCD.
6. To disable the auto-power-off hold the HOLD button while turning the unit on. If the auto­power-off is enabled (meter will turn off automat­ically) an APO will appear on the display. If Auto-power-off is disabled (meter will not turn off on its own), then no designation will appear on the LCD.
7. If you are in an environment where the tempera­ture is noticeably changing while you are taking your reading, it is advised that you disconnect the meter from the hoses and ZERO it relative
to ambient before each reading.
Checking Gas Pressure on a Regulator
1. Screw the brass fitting into the pressure port on the regulator.
2. Put unit into operation (i.e. turn on the furnace and have furnace ignite, as if running it in nor­mal operation.)
3. This will give you the pressure coming out of the regulator.
4. If you suspect high or low inlet pressure into the regulator, the manometer can hook into the inlet port in the same manner it can connect into the outlet port. If you have a dual-port manometer, you can check both the inlet and the outlet simultaneously and see the pressure drop across the regulator.
5. See manufacturer's specification for target inlet and outlet pressure for a given regulator or piece of combustion equipment.
Battery Check Function
Press and hold the UNIT button to display the percentage of usable battery remaining. This function can be used any time the meter on.
Field Calibration
Pressure:
By pressing the ZERO button, both the P1 and P2 are zeroed to the pressure they are being exposed to. For this reason the calibration should be done when both P1 and P2 are dis­connected from the hoses.
T2
88.88
88.88
PRESS FOR 1 SECOND
AUTO-OFF BATTERY
CHECK
Gas pressure measurement
Static pressure
across a blower
V15
Outlet Pressure
Tap Screw
Outlet
Pressure
Boss
Inlet Pressure Tap Screw
Smaller end (3/16”) of the adapter connects to SDMN5 tubing. Remove the installed brass fitting from tube so the adapter can be inserted.
Inlet Pressure Boss
Adapter
(5/16” to 3/16”)
Adapter Tube
(5/16”)
P1
APO
88.88
HOLD
88.88
P1 P2
HOLD UNIT
AUTO-OFF BATTERY
ON/OFF
PRESS FOR 1 SECOND
P2
ZERO
CHECK
mbar inWC
mmWC
psi
T2
T2
AUTO-OFF BATTERY
CHECK
PRESS FOR 1 SECOND
Page 2
ASP2 Static Pressure Probe
For accurate static pressure measurements.
1. Connect ASP2 to SDMN5 via hose.
2. Insert ASP2 into drilled or pre-existing 1/4” hole.
3. Use allignment arrow on the ASP2 to direct probe into the air stream.
4. Read static pressure measurements from the dis­play on the SDMN5
5. Remove probe and patch hole.
Note: For best accuracy on measurements less than
2inWC, take measureument within 1 minute of zeroing.
More Products From Fieldpiece
Modular Expandability
Modular expandability is ability for accessory heads and meters to change configurations to match the various needs of an HVAC/R technician.
Accessory heads (the sensors) send out a mV signal, which represents the value of the measure­ment, to whatever meter is attached to it. Heads can attach directly to the top of a Stick meter, DL3 data logger, or EHDL1. They can also plug into any meter with mV ranges using ASLS2 leads.
Stick Meter
This is the heart of modular expandability. In addi­tion to being a full functioning multimeter, any acces­sory head can be used with it.
Model HS36
Non contact voltage
Magnetic hanger
Autoranging
Backlight
Temperature
Volts, amps, ohms
Frequency
Microfarads
Includes:
HS36 Meter
ACH4 Current Clamp ATB1 K-type TCouple ADLS2 Deluxe Leads
ANC1 Case
Accessory Heads
Accessory heads are the sensors of multiple parameters measured by technicians every day. They plug into a mV range (depending on the head) of a multimeter. The multimeter will display whatev­er the head is measuring. Instead of having to pur­chase and carry a separate instrument for each parameter, a technician can use multiple heads and a single multimeter to do the job.
Here are four of the many heads available:
AAV3 Air Velocity and Temperature
ADMN2 Dual-Port Manometer
AVG2 Digital Vacuum Gauge
AOX2 Combustion Check
Air Velocity & Temperature Head
English
READLOBATT
ON
LCDX 100
Average
(16sec)
Metric
Real time
AAV3
AUTO-
OFF
English Metric
Ft/min M/s
KM/hrMPH ºF ºC
OFF
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
CLAMP
300V
CAT.III
400A
AC Current Clamp
!
1AAC / 1mVAC 400AAC MAX
ON
H
STABLE
LOBATT
ENGLIS
SH
t
ng
r ation
METRIC
R134A
SC
Refrige Superhea
and Subcooli
R404A
Temp
SH orSC
Pressu re
T/C
l
Ca
Set
M
AT
ON
Lo Batt
BLE
STA
Combustion
Check
ASX24
GAS
OIL
Fuel Type
AUTO
OFF
T/C
2
CAL
2
O
CO
%
TEMP
%
°C °F
AOX2
ACH4
O- F
AUT
OF
AirVelocity
&Temperature
Head
ON
LCD 100
X
Eng
READLOBATT
lish
Eng
Ft/minM/s
lish
Aver
Metri
(16sec)
age
c
Met
ºF ºC
ric
KM/hrMPH
OF
Real
F
time
AUT OFF
O-
AAV3
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
P1 P2
ON
Dual-Port
ON
Manometer Accessory
Lo Batt
Head
0.1 ENGLISH
Resolution
0.01 METRIC
(LCD/10)
P1-P2
P2 P1
AUTO
ZERO
OFF
ADMN2
Combustion Check
Lo Batt
STABLE
GAS
Fuel Type
OIL
TEMP
%CO
2
%O
2
AUTO
T/C
°C °F
CAL
OFF
AOX2