FIBARO Walli Outlet E, Walli Outlet F User Manual

Page 1
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
(https://manuals.baro.com)
Please choose page
Description and features
FGWOE-011 | FGWOF-011
Back To Top
Description
FIBARO Walli Outlet is a smart electrical outlet designed to control electrical devices via Z-Wave network. It measures active power and energy consumed by the controlled load. You can install it with provided cover plate and socket cover or other compatible.
Main features
Can turn ON/OFF plugged device remotely. Available in two versions for plug types:
Type E, Type F.
Can be used with FIBARO Walli covers or other compatible (see “Parts compatibility”):
GIRA – System 55 (Standard 55, E2, Event, Event Clear), Legrand – Céliane,
Schneider – Odace. Active power and energy consumption metering. Displays current load using multicolour LED frame (with FIBARO cover plate). Supports Z-Wave network Security Modes: S0 with AES-123 encryption and S2 Authenticated with PRNG­based encryption. Works as Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network). May be used with all devices certied with the Z-Wave Plus certicate and should be compatible with such devices produced by other manufacturers.
The device is a Security Enabled Z-Wave Plus product and a Security Enabled Z-Wave Controller must be used in order to fully utilize the product.
https://manuals.fibaro.com/walli-outlet/ 1/16
Page 2
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Back To Top
Back To Top
Specications
Power supply 110-230V~ 50/60 Hz
Rated load current 16A – resistive loads
Active element micro-gap relay μ
Recommended external overcurrent protection 16A type B circuit breaker
For installation in boxes Ø = 60mm, depth 50mm
Recommended wires
cross-section area between 1.5-4.0mm , stripped 15.5-16.5mm of insulation
Operating temperature 0–40°C
Ambient humidity 0–90% RH without condensation
Radio protocol Z-Wave (500 series chip)
Radio frequency band 868.0–868.6MHz; 869.7–870.0MHz
Max. transmitting power +6dBm
Range
up to 50m outdoors up to 40m indoors (depending on terrain and building structure)
Dimensions (Height x Width x Depth)
FGWOE-011: 86 x 86 x 48 mm FGWOF-011: 86 x 86 x 51 mm
Compliance with EU directives
RoHS 2011/65/EU RED 2014/53/EU
Radio frequency of individual device must be same as your Z-Wave controller. Check information on the box or consult your dealer if you are not sure.
2
Important safety information
Read this manual before attempting to install the device!
Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.
DANGER OF ELECTROCUTION!
The device is designed to operate in electrical home installation. Faulty connection or use may result
in re or electric shock.
https://manuals.fibaro.com/walli-outlet/ 2/16
Page 3
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Installation
Back To Top
All works on the device may be performed only by a qualied and licensed electrician. Observe
national regulations.
Even when the device is turned o, voltage may be present at its terminals. Any maintenance
introducing changes into the conguration of connections or the load must be always performed
with disabled fuse.
To avoid risk of electrical shock, do not operate the device with wet or moist hands.
Do not modify!
Do not modify this device in any way not included in this manual.
Other devices
The manufacturer, Fibar Group S.A. will not be held responsible for any damage or loss of warranty privileges for other connected devices if the connection is not compliant with their manuals.
This product is intended for indoor use only in dry locations.
Do not use in damp or wet locations, near a bathtub, sink, shower, swimming pool, or anywhere else where water or moisture are present. Not a toy! This product is not a toy. Keep away from children and animals!
Back To Top
Before installation
Connecting the device in a manner inconsistent with this manual may cause risk to health, life or material damage.
Do notpower the device before fully assembling it in the mounting box, Connect only in accordance to the diagram, Install only in ush mounting boxes compliant with a relevant national safety standards and with depth no less than 50mm, Do notconnect devices which are not compliant with the specication or relevant safety standards. Make sure you have all required parts when installing with covers other than FIBARO (see “Parts compatibility”).
Device parts:
1 – screw, 2 – socket cover, 3 – cover plate, 4 – unit (device), 5 – mounting frame
Preparing for installation
1 Remove the screw.
https://manuals.fibaro.com/walli-outlet/ 3/16
Page 4
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Back To Top
2 Take o the socket cover and cover plate.
3 Prepare wires by removing 15.5-16.5mm of insulation from their ends. Groove on the back of the
unit shows maximum wire length.
Back To Top
Electrical connection
1 Switch o the mains voltage (disable the fuse).
2 Connect the device according to the diagram:
Diagram: Example connection in electrical installation
3 Verify correctness of connection.
4 Tighten the terminal screws using PH1 screwdriver.
First assembly
When installing with FIBARO covers:
1 Insert the device with mounting frame into the mounting box and secure with mounting claws
and screws.
2 Snap the cover plate to the device.
https://manuals.fibaro.com/walli-outlet/ 4/16
Page 5
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Back To Top
3 Snap the socket cover to the device.
4 Secure with a screw.
5 Add the device to Z-Wave network.
Changing covers
For safety reasons the button should be used only with FIBARO cover. We recommend adding the device to Z-Wave network before changing the cover plate.
When installing with covers other than FIBARO, we recommend disabling the LED by changing parameter 13 to 0.
When installing with GIRA covers:
1 Switch o the mains voltage (disable the fuse).
2 Dismount the socket cover and cover plate.
3 Dismount shutter mechanism using pliers.
4 Snap the new cover plate to the device.
5 Snap the new socket cover to the device.
https://manuals.fibaro.com/walli-outlet/ 5/16
Page 6
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
6 Secure with a screw.
7 Switch on the mains voltage.
When installing with Legrand covers:
1 Switch o the mains voltage (disable the fuse).
2 Dismount the socket cover and cover plate.
3 Take the device out of the mounting box and detach the wires.
4 Replace FIBARO mounting frame with Legrand mounting frame (FG-Wx-AS-4002).
5 Connect wires according to “Electrical connection”
6 Insert the device with mounting frame into the mounting box and secure with mounting claws
and screws.
7 Snap the new cover plate to the device.
8 Snap the new socket cover to the device.
9 Switch on the mains voltage.
When installing with Schneider covers:
1 Switch o the mains voltage (disable the fuse).
2 Dismount the socket cover and cover plate.
3 Take the device out of the mounting box and detach the wires.
4 Replace FIBARO mounting frame with Schneider mounting frame (FG-Wx-AS-4003).
5 Connect wires according to“Electrical connection”.
https://manuals.fibaro.com/walli-outlet/ 6/16
Page 7
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Back To Top
6 Insert the device with mounting frame into the mounting box and secure with mounting claws
and screws.
7 Snap the new cover plate to the device.
8 Snap the new socket cover to the device.
9 Switch on the mains voltage.
Parts compatibility
Available FIBARO parts Included
Name Symbol FGWOF-011 FGWOE-011
Socket F Unit FG-WO-AS-4002 x
Socket E Unit FG-WO-AS-4003 x
Socket F FG-WO-PP-0010 x
Socket E FG-WO-PP-0009 x
Outer Lightguide FG-WO-PP-0004 x x
Shutter Unit FG-WO-AS-4001 x x
Mounting Frame FIBARO/GIRA FG-Wx-AS-4001 x x
Mounting Frame Legrand FG-Wx-AS-4002
Mounting Frame Schneider FG-Wx-AS-4003
Single Cover Plate FG-Wx-PP-0001 x x
https://manuals.fibaro.com/walli-outlet/ 7/16
Page 8
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Double Cover Plate FG-Wx-PP-0003
Triple Cover Plate FG-Wx-PP-0004
Parts required for GIRA System 55 (only with non-metalised outer surface: Standard 55, E2, Event, Event Clear) covers
Required FIBARO parts Socket type
Name Symbol GIRA Type F GIRA Type E
Socket F Unit FG-WO-AS-4002 x
Socket E Unit FG-WO-AS-4003 x
Mounting Frame FIBARO/GIRA FG-Wx-AS-4001 x x
Parts required for Legrand Céliane covers
Required FIBARO parts Socket type
Name Symbol Legrand Type F Legrand Type E
Socket F Unit FG-WO-AS-4002 x
Socket E Unit FG-WO-AS-4003 x
Mounting Frame Legrand FG-Wx-AS-4002 x x
Shutter Unit FG-WO-AS-4001 x x
Parts required for Schneider Odace covers
Required FIBARO parts Socket type
Name Symbol Schneider Type F Schneider Type E
Socket F Unit FG-WO-AS-4002 x
Socket E Unit FG-WO-AS-4003 x
Mounting Frame Schneider FG-Wx-AS-4003 x x
Shutter Unit FG-WO-AS-4001 x x
https://manuals.fibaro.com/walli-outlet/ 8/16
Page 9
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Z-Wave network
Back To Top
Generic Home Center SmartThings Vera Homey
Adding to Z-Wave network
Adding (Inclusion)– Z-Wave device learning mode, allowing to add the device to existing Z-Wave network.
1 Button,
2 LED ring.
Full DSK code is present only on the box, make sure to keep it or copy the code.
Adding manually
Use the button only with FIBARO cover to ensure safety.
To add the device to the Z-Wave networkmanually:
1 Power the device.
2 Set the main controller into the adding mode (see the controller’s manual).
3 Quickly, three times click the button.
4 If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on
the bottom of the box).
5 LED will start blinking yellow, wait for the adding process to end.
6 Adding result will be conrmed by the Z-Wave controller’s message and the LED frame:
Green– successful (non-secure, S0, S2 non-authenticated), Magenta– successful (Security S2 Authenticated), Red– not successful.
Adding using SmartStart
SmartStartenabled products can be added to SmartStart enabled Z-Wave controller by scanning the Z-Wave QR Code present on the product. SmartStart product will be added automatically within 10 minutes of being switched on in the network range.
https://manuals.fibaro.com/walli-outlet/ 9/16
Page 10
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Back To Top
To add the device to the Z-Wave networkusing SmartStart:
1 To use SmartStart your controller needs to support Security S2 (see the controller’s manual).
2 Enter the full DSK string code to your controller. If your controller is capable of QR scanning, scan
the QR code placed on the label on the bottom of the box.
3 Power the device.
4 Wait for the adding process to start (up to few minutes), which is signalled with yellow LED
blinking.
5 Adding result will be conrmed by the Z-Wave controller’s message and the LED frame:
Green– successful (non-secure, S0, S2 non-authenticated), Magenta– successful (Security S2 Authenticated), Red– not successful.
In case of problems with adding the device, please reset the device and repeat the adding procedure.
Generic Home Center SmartThings Vera Homey
Removing from Z-Wave network
Use the button only with FIBARO cover to ensure safety.
1 Button,
2 LED ring.
Removing (Exclusion)– Z-Wave device learning mode, allowing to remove the device from existing Z-Wave
network. Removing also results in resetting the device to factory defaults.
Toremovethe device from the Z-Wave network:
1 Power the device.
2 Set the main controller in remove mode (see the controller's manual).
3 Quickly, three times click the button.
4 LED will start blinking yellow, wait for the removing process to end.
https://manuals.fibaro.com/walli-outlet/ 10/16
Page 11
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Operating the device
Back To Top
5 Successful removing will be conrmed by the Z-Wave controller’s message and red LED
colour.
Back To Top
Z-Wave range test
The device has a built in Z-Wave network main controller’s range tester.
To make Z-Wave range test possible, the device must be added to the Z-Wave controller. Testing may stress the network, so it is recommended to perform the test only in special cases.
To test the main controller’s range:
1 Press and hold the button to enter the menu.
2 Release button when the device glows magenta.
3 Quickly click the button to conrm.
4 Visual indicator will indicate the Z-Wave network’s range (range signalling modes described
below).
5 To exit Z-Wave range test, press the button briey.
Z-Wave range tester signalling modes:
Visual indicator pulsing green– the device attempts to establish a direct communication with the main
controller. If a direct communication attempt fails, the device will try to establish a routed communication, through other modules, which will be signalled by visual indicator pulsing yellow.
Visual indicator glowing green– the device communicates with the main controller directly. Visual indicator pulsing yellow– the device tries to establish a routed communication with the main
controller through other modules (repeaters). Visual indicator glowing yellow– the device communicates with the main controller through the other modules. After 2 seconds the device will retry to establish a direct communication with the main controller, which will be signalled with visual indicator pulsing green. Visual indicator pulsing violet– the device does communicate at the maximum distance of the Z-Wave network. If connection proves successful it will be conrmed with a yellow glow. It’s not recommended to use the device at the range limit. Visual indicator glowing red– the device is not able to connect to the main controller directly or through another Z-Wave network device (repeater).
Communication mode of the device may switch between direct and one using routing, especially if the device is on the limit of the direct range.
Controls
https://manuals.fibaro.com/walli-outlet/ 11/16
Page 12
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Back To Top
1 Button,
2 LED ring.
Use the button only with FIBARO cover to ensure safety.
Back To Top
Button control
1xClick – change to the opposite state (ON/OFF), 3xClick – start learn mode to add/remove to/from Z-Wave network, Press and hold – enter the menu.
Back To Top
Visual indications
The built-in LED light shows current device status.
After powering the device:
Green – device added to a Z-Wave network (non-secure, S0, S2 non-authenticated), Magenta – device added to a Z-Wave network (Security S2 Authenticated), Red – device not added to a Z-Wave network.
State of the device:
Colour depending on current load – device turned ON (by default).
Update:
Blinking cyan – update in progress, Green – update successful, Red – update not successful.
Menu:
Blinking green – entering the menu (added as non-secure, S0, S2 non-authenticated), Blinking magenta – entering the menu (added as Security S2 Authenticated), Blinking red – entering the menu (not added to a Z-Wave network), Green – reset energy consumption memory, Magenta – start Z-Wave range test, Yellow – reset to factory defaults.
Menu
Menuallows to perform Z-Wave network actions. In order to use the menu:
https://manuals.fibaro.com/walli-outlet/ 12/16
Page 13
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Additional features
Back To Top
1 Press and hold the button to enter the menu, device blinks to signal adding status (see: Visual
indications).
2 Release the button when device signals desired position with colour:
GREEN– reset energy consumption memory MAGENTA– start Z-Wave range test YELLOW– reset to factory defaults
3 Quickly click the button to conrm.
Back To Top
Resetting to factory defaults
Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user conguration will be deleted. Resetting to factory defaults does not reset energy consumption memory.
Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described.
Use the button only with FIBARO cover to ensure safety.
1 Press and hold the button to enter the menu.
2 Release the button when the device glows yellow.
3 Quickly click the button to conrm.
4 Device will blink yellow to conrm.
5 After a few seconds the device will be restarted, which is signalled with red LED colour.
Power and energy metering
The device allows for the active power and energy consumption monitoring. Data is sent to the main Z-Wave controller, e.g. Home Center.
Measuring is carried out by the most advanced microcontroller technology, assuring maximum accuracy and precision (+/- 1% for loads greater than 5W).
Electric active power– power that energy receiver is changing into a work or a heat. The unit of active power is Watt [W].
https://manuals.fibaro.com/walli-outlet/ 13/16
Page 14
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Conguration
Back To Top
Power measurement can contain mains voltage uctuations within +/- 10%.
Electric energy– energy consumed by a device through a time period. Consumers of electricity in households are billed by suppliers on the basis of active power used in given unit of time. Most commonly measured in kilowatt-hour [kWh]. One kilowatt-hour is equal to one kilowatt of power consumed over period of one hour, 1kWh = 1000Wh.
Resetting consumption memory:
Use the button only with FIBARO cover to ensure safety.
1 Press and hold the button to enter the menu.
2 Release button when the device glows green.
3 Quickly click the button to conrm.
4 Device will blink two times green to conrm.
The device stores periodically (every hour) the consumption data in the device memory. Disconnecting the module from the power supply will not erase stored energy consumption data.
Back To Top
Associations
Association (linking devices)– direct control of other devices within the Z-Wave system network.
Associations allow:
reporting the device status to the Z-Wave controller (using Lifeline group), creating simple automations by controlling other devices without participation of the main controller (using groups assigned to actions on the device).
The device provides the association of 2 groups:
1st association group – “Lifeline”reports the device status and allows for assigning single device only (main
controller by default).
2nd association group – “Power”devices in this group will be switched on or o depending on the current load of plugged device (uses Basic command class). Power thresholds and behaviour are congured using parameters 45-49. Allows to control 5 regular or multichannel devices.
Advanced parameters
https://manuals.fibaro.com/walli-outlet/ 14/16
Page 15
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Back To Top
The device allows to customize its operation to user’s needs using congurable parameters. The settings can be adjusted via Z-Wave controller to which the device is added. The way of adjusting them might dier depending on the controller. In the FIBARO interface parameters are presented as simple options in Advanced Settings of the device.
Available parameters:
1. Remember device state
2. Overload safety switch
10. LED frame – power limit
11. LED frame – colour when ON
12. LED frame – colour when OFF
13. LED frame – brightness
30. Alarm conguration - 1st slot
31. Alarm conguration - 2nd slot
32. Alarm conguration - 3rd slot
33. Alarm conguration - 4th slot
34. Alarm conguration - 5th slot
35. Alarm conguration – duration
45. Associations – 2nd group
46. Associations – UP threshold
47. Associations – UP threshold frame value
48. Associations – DOWN threshold
49. Associations – DOWN threshold frame value
60. Power reports – include self-consumption
61. Power reports – on change
62. Power reports – periodic
65. Energy reports – on change
66. Energy reports – periodic
https://manuals.fibaro.com/walli-outlet/ 15/16
Page 16
17/06/2019 Walli Outlet - E/F | FIBARO Manuals
Description and features
Description
Main features
Specications
Important safety information
Installation
Z-Wave network
Operating the device
Additional features
Conguration
© 2019. FIBAR GROUP S.A. All rights reserved.
https://manuals.fibaro.com/walli-outlet/ 16/16
Loading...