With a simple configuration
the boiler can run on natural
gas or LPG without using
additional conversion kits
Reaches one of the
highest seasonal space
heating efficiencies in its
category (η
94%)
s
Page 6
BOILER CONTROL
Control board and functions
BLUEHELIX HITECH RRT
24 C / 28 C / 34 C
easy
EASY...
It’s quick and easy to achieve optimum comfort thanks
to the smart new user interface with ‘CapSense’ touch
screen technology and large 2.8” graphic display.
The boiler is also designed to deliver even greater
comfort by connecting to a second room thermostat
for multi-zone heating control.
EASY
CONTROL
5
12
8
14
14
7
10
9
13
11
24
136
KEY 1 Decrease DHW temperature setting 2 Increase DHW temperature setting 3 Decrease heating system temperature setting 4 Increase heating
system temperature setting 5 Display 6 Back key 7 Winter, Summer, Appliance OFF, ECO, COMFORT mode selection 8 ECO mode indicator 9 DHW mode
indicator 10 Summer/Winter mode indicator 11 Menu / confirm key 12 System pressure indicator 13 Heating mode indicator 14 Burner on indicator
Page 7
BLUEHELIX HITECH RRT
24 C / 28 C / 34 C
HEAT ENGINE
Combustion chamber
The stainless steel water section of the heat exchanger in the BLUEHELIX HITECH RRT ensures an extremely smooth surface that
significantly reduces the problem of scaling and deposits.
The increased extra section,
smooth surface and coil
section drastically reduce
the amount of deposits inside
the pipe and considerably
increase the service life of
the heat exchanger
Air-cooled burner door requiring
no insulation panel (will not break
during maintenance)
Unique hemispherical
stainless steel burner
DESIGNED FOR OPTIMUM EFFICIENCY
The patented stainless steel heat exchanger of the THERMOBALANCE™ thermal unit used
in the BLUEHELIX HITECH RRT (fig. A) can be compared to the most traditional and widely
fig. A *
fig. B *
used steel heat exchanger (fig. B).
This design enables the heat exchanger to work at maximum efficiency, even in partially
clogged conditions. With the same amount of deposits and sediment (e.g. due to
installation on old systems), the heat exchanger in fig. B tends to get clogged more
quickly in the part in contact with the flame as a result of the reduced fluid flow area,
where a barrier of deposits* forms, obstructing the heat exchanger and reducing the
efficiency to below nominal values.
DURABLE AND RELIABLE
Ferroli’s Thermobalance™ heat exchanger has better insulation and wider waterways than
standard heating systems, helping to maintain higher efficiency levels and reduce maintenance,
even on older systems.
* Ref.: same amount (5 gr.) of scaling and deposits in heat exchanger (A) and (B), with the same pipe length section. Scale 150% of the
actual measurement.
Heat exchange section showing immediate heat contact surface area
Page 8
M C
2
M C
2
BLUEHELIX HITECH RRT
24 C / 28 C / 34 C
MC
2
Multi Combustion Control
MC2: Multi Combustion Control is a new combustion system with gas adaptive patented technology that
automatically adapts the level of combustion as the flue or gas conditions change. This is controlled by the
flame ionisation current to ensure perfect combustion according to the change in air density or gas quality.
The ratio between the air/gas flow (λ) and the flame ionisation detection electrode is used to automatically
adjust the air-gas ratio and, therefore, combustion.
MULTI COMB.
CONTROL
Page 9
EASY MAINTENANCE
BLUEHELIX HITECH RRT
24 C / 28 C / 34 C
When servicing the boiler for the first time, engineers will appreciate the care with which each part has been
designed in order to make their work straightforward and hassle-free.
- All main components can be easily accessed by removing the 3-piece casing.
- The electric box of the electronic board can be easily removed from the chassis, giving free access to the
internal parts.
- The fan offset from the burner is situated underneath and removal is not necessary in order to access the burner and
heat exchanger assembly.
- The burner door is fully air-cooled and does not require an insulating panel, which avoids the risk of it being damaged
during cleaning.
- The burner is removed by unscrewing only three bolts, giving free access to the stainless steel heat exchanger.
- The high-pass primary heat exchanger is designed to challenge extremely hard water conditions and can be easily cleaned
thanks to the non-manifold single pipe circuit.
- The DHW inlet lter can be removed directly from the inside without having to remove the boiler water connections.
- Disassembly and replacement of the plate heat exchanger is carried out easily by removing two hex bolts that can be accessed
from the front.
- Easy access to the external wiring connections without having to lower the front panel.
Page 10
F
P
S
F
P
S
BLUEHELIX HITECH RRT
SIMPLIFIED BOILER REPLACEMENT
Ideal for approved collective flue systems
24 C / 28 C / 34 C
FPS: Flue Gas Protection System. The flue gas check valve (installed as standard) offers
easy connection to pressurised collective ue systems (e.g. in redevelopment projects).
The collective pressurised flue solution is more cost-effective for installers working with
smaller diameter chimneys.
COLLECTIVE
PRESSURISED
Page 11
NEW FERROLI TECHNOLOGY
1 : 10
The right choice for you
BLUEHELIX HITECH RRT
24 C / 28 C / 34 C
BLUEHELIX HITECH RRT
24 C - 28 C - 34 C
RANGE
THERMO
BALANCE
Page 12
COMFORT AND SAFETY
Functions
BLUEHELIX HITECH RRT
24 C / 28 C / 34 C
STOP AND GO
Using mixer taps for very short bursts causes the boiler ignition procedure to start up, which usually ends
immediately. Over time, these false starts can affect the average service life of the product. To prevent this,
the BLUEHELIX HITECH RRT has been equipped with ‘Stop and Go’, an electronic parameter that delays
burner ignition so that it only activates if hot water is actually used.
SUN EASY
The BLUEHELIX HITECH RRT has been designed to easily integrate into systems built with the latest
technology. The Sun Easy system is equipped with electronics that simplify operation with solar
panels, with both natural and forced circulation. A sensor situated on the DHW circuit constantly controls
the preheated water temperature from the solar panels, providing burner ignition only if this temperature
drops below the level required to ensure optimal user comfort.
DHW ECO-COMFORT
In ECO mode, DHW production is provided in the traditional way and saves energy by not preheating the
water. In COMFORT mode, thanks to the special temperature maintenance system of the heat exchanger,
hot water supply is even faster and more convenient, reaching the maximum certified 3-star comfort.
The efficiency and load profiles according to the ErP directive are at the top of the category (24 C & 28 C
/ A - XL | 34 C / A – XXL).
STOP AND GO
MODE
DHW
Page 13
CHARACTERISTICS
Hydraulics
BLUEHELIX HITECH RRT
24 C / 28 C / 34 C
KEY 8 DHW outlet 9 DHW inlet 10 System delivery 11 System return 14 Safety valve 32 Heating circulator 34 Heating temperature sensor 36 Automatic
air vent 42 DHW temperature sensor 56 Expansion vessel 74 System filling tap 95 Diverter valve 136 Flowmeter 186 Return sensor 193 Siphon 194 DHW
heat exchanger 241 Automatic bypass 294 System pressure sensor
In accordance with Ferroli Limited’s aim to constantly improve production ranges and
customer satisfaction levels, please be aware that aesthetic and/or dimensional features,
specifications and accessories may be subject to change.
Please take the utmost care to ensure that all technical and/or sales documents (lists,
catalogues, brochures etc.) provided to the customer have been updated according to the
latest edition.
Ferroli Ltd
The Granary, Borough Hill Farm, Catton Road,
Walton on Trent, Derbyshire, DE12 8LL