Feig Electronic OBID i-scan ID ISC.PRH102-B Installation Manual

OBID i-scan
®
ID ISC.PRH102-B
INSTALLATION
final public (B) 2010-06-29 M91101-0e-ID-B.doc
OBID i-scan
®
Installation ID ISC.PRH102
Note
© Copyright 2009-2010 by
FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu­ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
®
is a registered trademark of Infineon Technologies AG
my-d I-CODE Tag-it Bluetooth
®
is a registered trademark of Philips Electronics N.V.
TM
is a registered trademark of Texas Instruments Incorporated.
TM
is a registered trademark of Bluetooth SIG Inc.
FEIG ELECTRONIC GmbH Page 2 of 18 M91101-0e-ID-B.doc
OBID i-scan
®
Installation ID ISC.PRH102
Contents
1. Safety Instructions / Warning - Read before start-up ! 4
2. Performance Features of the ID ISC.PRH102 5
2.1. Performance features .........................................................................................................5
2.2. Available Reader-Types......................................................................................................5
3. Control and Display Elements 6
3.1. Signal buzzer.......................................................................................................................6
3.2. Scan - button .......................................................................................................................6
3.3. LED.......................................................................................................................................7
4. Assembly and Wiring 8
4.1. Reader with Bluetooth™ interface ID ISC.PRH102-B....................................................... 8
4.1.1. Bluetooth™(BT) interface..............................................................................................8
4.1.2. Supply voltage...............................................................................................................9
4.1.3. Charging the batteries .................................................................................................10
4.1.4. Reset - button ID ISC.PRH102-B ................................................................................11
5. Technical Data 13
6. Approvals 15
6.1. Europe (CE).......................................................................................................................15
6.2. Declaration of Conformity................................................................................................16
6.3. USA and Canada (FCC and IC).........................................................................................17
7. Appendix 18
7.1. Accessories.......................................................................................................................18
7.2. Scope of delivery...............................................................................................................18
FEIG ELECTRONIC GmbH Page 3 of 18 M91101-0e-ID-B.doc
OBID i-scan
®
Installation ID ISC.PRH102
1. Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer.
When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation
of 20 cm (8 inch) between antenna and the human body must be maintained.
The operation manual should be conveniently kept available at all times for each user.
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device.
Repairs may only be executed by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
Use of the device and its installation must be in accordance with national legal requirements and local electrical codes .
When working on devices the valid safety regulations must be observed.
Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm (10 inch) between the device and your cardiac pacemaker.
FEIG ELECTRONIC GmbH Page 4 of 18 M91101-0e-ID-B.doc
OBID i-scan
®
Installation ID ISC.PRH102
2. Performance Features of the ID ISC.PRH102
2.1. Performance features
The ID ISC.PRH102 are devices for contactless data exchange with common Transponder ac­cording ISO 15693. The readers have an internal antenna and will be delivered ready for connec­tion. The device is designed as a handheld.
An anti-collision function enables simultaneous reading of several transponders per second. The Reader electronic is fitted in a plastic housing with a protection class IP30.
The Reader ID ISC.PRH102-B has an Bluetooth interface
2.2. Available Reader-Types
Following Reader-Types are available at present:
Reader-Types Description
ID ISC.PRH102-B Bluetooth interface with internal antenna and
voltage supply by means of 4 rechargeable Mignon AA batteries
Table 1: Reader-Types
FEIG ELECTRONIC GmbH Page 5 of 18 M91101-0e-ID-B.doc
OBID i-scan
®
3. Control and Display Elements
LED
Installation ID ISC.PRH102

Scan-button

Fig. 1: Control and Display Elements
3.1. Signal buzzer
The signal buzzer can be configured by the software. In the standard configuration the signal buzzer will be active if a Transponder is recognised.
3.2. Scan - button
The switch of the reader can be configured by the software. In the standard configuration the serial number of the Transponder is read and is sent to the host
after pressing the scan - button.
FEIG ELECTRONIC GmbH Page 6 of 18 M91101-0e-ID-B.doc