FEIG ELECTRONIC GmbH Lange Straße 4 35781 Weilburg/Lahn
14.05.03
MWD BFInstruction manual
General
Copyright 2003 byFEIG ELECTRONIC GmbH
Lange Straße 4
D - 35781 Weilburg
The indications made in these operating instructions may be altered without previous notice.
With the edition of these instructions, all previous editions become void.
Composition of the information given in this manual has been done to the best of our
knowledge. FEIG ELECTRONIC does not guarantee the correctness of the details given in
these instructions and may not be held liable for damages ensuing from incorrect installation.
Since, despite of all our efforts, errors may not be completely avoided, we are always grateful
for your useful tips.
The installation instructions given in this manual are based on advantageous boundary
conditions. FEIG ELECTRONIC does not give any guarantee promise for perfect function of the
traffic detector in a cross surrounding.
Copy or reproduction of these instructions, even if only partial, as well as translation into other
languages is forbidden unless a written consent has been granted by FEIG ELECTRONIC. This
also applies to the complete or partial storage of these operating instructions on modern inputand output media for further processing in data processing systems.
Please read the operating- and safety instructions thoroughly before putting the motion
detector into operation!!
The MWD BF is a radar motion detector with direction identification, which has been especially
designed for applications in the area of industrial gate- and barrier systems. In some cases, the
operational parameters may also be adjusted with an infrared remote control.
Motion detection is done according to the Doppler’s principle. The sensor sends out 24 GHz
microwaves. These microwaves are reflected by objects in motion and thus their frequency
changes. The sensor receives these altered frequencies and analyses them. Thus, each motion
within the detection range is recorded, analysed by a logic and transmitted to the gate- resp.
barrier control by connecting potential-free change-over contacts.
Range of application:
Entry-/access recognition for the drive of industrial gate- and barrier systems
Special features:
• Insensitive to fluctuations of temperature and humidity
• Distinction vehicles/persons
• Reversible and cutoff direction logic
• Adjustable sensitivity
• Potential-free relay exit with change-over contacts
• Large supply voltage range - AC or DC
• Adjustment of operational parameters by key buttons or infrared remote control
• Compact plastic housing
• IP 65 housing
• Easy and fast installation with mounting bracket
405/03FEIG ELECTRONIC GmbH
Instruction manualMWD BF
2Installation
2.1Place of installation
The device is centrally mounted above the area to be monitored. Both wall- and ceiling mountig
are possible. The maximum mounting height is approx. 6m.
Hints for planning and installation:
• The device has to be mounted vibrationless.
• In order to avoid incorrect release, there must not be any objects in motion within the
radiation field.
• There must not be any fluorescent tubes within the radiation field of the detector.
• It should be avoided that the radiation fields of two motion detectors overlap, since this may
lead to incorrect releases.
• Do not install behind objects, building coverings or elements.
• If the motion detector is exposed to rain or snow, it should be adjusted to directional
recognition.
• If conductive floors are used and the radiation direction is almost vertical, incorrect releases
may be caused by reflections.
2.2Mounting of the bracket
The bracket is suitable for both wall- and ceiling mounting. In case of ceiling mounting, it has to
be turned by 180° opposite the housing of the motion detector.
2.3How to connect the motion detector
Connection is done as shown in figure 2. Deposit the leads of the flexible connecting cable
10 cm from the appliance, lead it through the lateral PG-screwing and fix it.
In case of DC power supply, polarity is insignificant.
10cm
2.4How to screw down the housing
The cover should be screwed down with a torque of approx. 1 Nm. Put the cover evenly into the
groove of the housing and screw it down.
Attention! If the cover is tilt, for example due to squeezed cable leads in between the screw
guides, the tightness of the housing is not guaranteed!
FEIG ELECTRONIC GmbH05/035