Feig Electronic MRU102 User Manual

Date: 2012-06-11 Vers. no. 1.12
m. dudde hochfrequenz-technik
D-51429 Bergisch Gladbach/ Germany
Tel: +49 2207-96890
Fax +49 2207-968920
Annex no. 5
User Manual
ID ISC.MRMU102-A
INTEGRATION
Module Version
final – public (B) 2012-12-03 – Integration
Manual M21112-1e-ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
Note
Copyright 2012 by
FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures.
Use Exclusion in Transportation Market: Devices which are subject of this document may NOT be sold, used, leased, offer for sale, or otherwise transferred, exported, and imported by anyone in the Transportation Market. “Transportation Market” means (i) Electronic Toll and Traffic Management (ETTM), (ii) Public Sector Vehicle Registration, Inspection and Licensing Programs, (iii) Railroad Locomotive and Wagon tracking, (iv) airport based ground transportation management systems (GTMS) and taxi dispatch, (v) revenue based parking, and (vi) vehicle initiated mobile payment applications, where the RFID sticker/tag is initially attached to the vehicle but not incorporated at the point of vehicle manufacture.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu­ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
®
and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
OBID
FEIG ELECTRONIC GmbH Page 2 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
General information's r e gar ding this document
The sign "" indicates extensions or changes of this manual compared with the former issue.
If bits within one byte are filled with "-", these bit spaces are reserved for future extensions or
for internal testing- and manufacturing-functions. These bit spaces must not be changed, as this may cause faulty operation of the reader.
The following figure formats are used:
0...9: for decimal figures 0x00...0xFF: for hexadecimal figures, b0...1 for binary figures.
The hexadecimal value in brackets "[ ]" marks a control byte (command).
FEIG ELECTRONIC GmbH Page 3 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
Contents
1. Safety Instructions / Warning - Read before start-up ! 5
2. Performance Features of the Reader 6
2.1. Available Reader Types .................................................................................................... 6
2.2. Optional Accessories ........................................................................................................ 6
3. Assembly and Wiring 7
3.1. Module Versions ................................................................................................................ 7
3.1.1. Dimensions .................................................................................................................. 7
4. Connections 8
4.1. Antenna Terminals ............................................................................................................ 8
4.1.1. External Antenna ANT 1 - 3 ......................................................................................... 8
4.1.2. Internal Antenna ANT 4 .............................................................................................. 10
4.2. Power Supply via Connector X1 ..................................................................................... 10
4.3. RS232 Interface on Connector X2 .................................................................................. 11
4.4. USB Interface on Connector X3 ...................................................................................... 12
5. Control and Display Elements 12
5.1. LED ................................................................................................................................... 12
6. Technical Data 13
7. Radio Approvals 16
7.1. Europe (CE) ...................................................................................................................... 16
7.2. Declaration of Conformity ............................................................................................... 17
FEIG ELECTRONIC GmbH Page 4 of 21 Integration Manual M21112-1e-
7.3. USA (FCC) and Canada (IC) ............................................................................................ 19
7.3.1. USA (FCC) and Canada (IC) warning notices ............................................................ 19
7.3.2. USA (FCC) and Canada (IC) approved antennas ...................................................... 20
ANNEX A - Accessories ......................................................................................................... 21
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
1. Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer.
The operation manual should be conveniently kept available at all times for each user.
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device.
Repairs may only be executed by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
Use of the device and its installation must be in accordance with national legal requirements and local electrical codes .
When working on devices the valid safety regulations must be observed.
Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in an immediate proximity of the device respective the antenna for some time.
FEIG ELECTRONIC GmbH Page 5 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
Module version with asynchronous RS232- and USB-Interface;
2. Performance Features of the Reader
The Reader ID ISC.MRMU102 is designed for reading of passive data carriers, so-called „Smart Labels“ at an operating frequency in the UHF band between 860 MHz and 960 MHz. Transponders according to EPC Class1 Gen2 are supported. Optional an Upgrade Code for the reading of ISO 18000-6-C transponders is available. The reader is designed for application with small tag popula­tion.
The reader module is equipped with 3 SMA connectors for conduction of external antennas (ANT1 – ANT3). Additional an integrated antenna (ANT4) is available.
For Host communication the reader provides an asynchronous RS232 interface and an USB inter­face.
The reader is designed for use in applications with small tag populations. Maximum 10 tags at the same time into the antenna field can be processed.
2.1. Available Reader Types
The following reader types are currently available:
Table 1: Available Reader Types
Reader type Description
ID ISC.MRMU102-A
3 SMA connectors for external antennas; 1 integrated antenna;
2.2. Optional Accessories
Optional Accessories are listed in the appendix.
FEIG ELECTRONIC GmbH Page 6 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
77
137
Ø3,3
Ø7
125
107,5
65
LED
ANT1
FE 741
68,5
54,5
29,5
X2
X3
38,5
ANT2
22,5
ANT3
4,75
3. Assembly and Wiring
3.1. Module Versions
This reader version has been designed for mounting in other equipment.
NOTE: Before any installation the intended position of the reader should be tested for its suitabil-
ity.
3.1.1. Dimensions
FEIG ELECTRONIC GmbH Page 7 of 21 Integration Manual M21112-1e-
Figure 1: Dimensions of the housing version (all dimensions are in mm)
[DB1]
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
4. Connections
The module version of the reader is equipped with an asynchronous RS232 Interface (X2) and a USB Interface (X3). The Table 2: Connectors shows which connector can be used for the different interface cable.
Table 2: Connectors
Connector Description
ANT 1-3 External Antenna ANT 1 - 3
ANT 4 Internal Antenna ANT 4
X1 Power Supply via Connector X1
X2 RS232 Interface on Connector X2
X3 USB Interface on Connector X3
4.1. Antenna Terminals
4.1.1. External Antenna ANT 1 - 3
Three SMA sockets are provided on the circuit board for connecting of the external antennas. The maximum tightening torque for the SMA socket is 0.45 Nm.
CAUTION: Higher tightening torque will damage the connector.
Table 3: Connecting an external antenna
Terminal Description
NOTE: When connecting an antenna, ensure that it does not exceed the permissible limits pre-
scribed by the national regulations for radio frequency devices.
FEIG ELECTRONIC GmbH Page 8 of 21 Integration Manual M21112-1e-
ANT 1-3 Connecting the external antenna
(input impedance 50Ω)
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
FEIG ELECTRONIC GmbH Page 9 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
4.1.2. Internal Antenna ANT 4
Additionally the reader is equipped with an internal antenna (ANT4). The internal antenna supports far field transponders as well as near field transponders. The internal antenna is located in the bot­tom left corner of the housing and is marked with an antenna symbol. The maximum read range of the antenna in combination with a far field transponder is approx. 40 cm. In combination with a near field transponder the maximum read range is approx. 5 cm.
Figure 2: Position of the internal antenna
4.2. Power Supply via Connector X1
The reader needs to be supplied by an external voltage of 12 V DC to 24 V DC. Connect the 12 ­24 V DC/
NOTE: Reversing the polarity of the supply voltage may destroy the device.
The unit has to supplied by a listed NEC Class 2/LPS Power supply, only
supply voltage to socket X1 on the circuit board.
Terminal Name Description X 1
X1 / inside Vcc Vcc – supply voltage (+)
X1 / outside GND Ground – supply voltage (-)
Table 4: Connecting the supply voltage
NOTE: The power supply is supplied with a DC/
the readers socket X1.
FEIG ELECTRONIC GmbH Page 10 of 21 Integration Manual M21112-1e-
plug 2.5mm x 5.5mm. This is compatible with
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
4.3. RS232 Interface on Connector X2
For the connection of the asynchronous interface RS232 the reader provides a 9-pin D­Subminiature female connector. (See also
Table 5: Connection assignment of the connector X2
X2 Interface
2 TxD
3 RxD
5 GND
7 GND
1;4;6;8;9 n.c.
Connections).
For this reader a serial cable is available. Table 6: Serial Data Cable
Feig Part No. Description
1690.000.00 ID CAB.RS-A
Interface parameter can be configured via software protocol (e.g. ISOStart). Further information can be found in the System Manual H10410-Xe-ID-B.pdf of the reader.
FEIG ELECTRONIC GmbH Page 11 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
4.2. USB Interface on Connector X3
There is a USB-socket X3 on board for the connection of the USB-Interface. The pinout is stand­ardized. The data rate is reduced to 12 Mbit (USB full speed). A standard USB-cable can be used.
Figure 3: USB interface for host communication
NOTE: The length of the USB-cable can be a max. of 5 meter. It isn’t allowed to use longer cables! The reader must be powered with a external power supply even if it is connected to a “high
powered port”.
5. Control and Display Elements
5.1. LED
The Reader’s LED can be configured through software. The following Table 8: Default Configuration of the LEDs shows the default setting.
Table 7: Default Configuration of the LEDs
Abbreviation Description
LED green
"RUN "
- Turns on when the Reader is ready
FEIG ELECTRONIC GmbH Page 12 of 21 Integration Manual M21112-1e-
LED red
LED orange
„LABEL“
- Turns on when a transponder is detected.
- Flashes if RF-Warning (red – green alternating with 8Hz)
(Temperature alarm, short circuit on antenna output)
„INITIALIZING“
- Flashes during Reader initialization after power-up.
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
6. Technical Data
MECHANICAL DATA
Housing ­Dimension (W x H x D) 137 mm x 77 mm x 17 mm Weight 60 g Protection Class ­Colour -
ELECTRICAL DATA
Power Supply 12 V DC – 24 V DC Power Consumption max. 7 W Operating Frequency 860 MHz to 960 MHz RF-Power
Antenna Connector
max. 500 mW ± 1,5 dB 3 x SMA female(50 )
1 x integrated Antenna (ANT4)
Interfaces USB (Full Speed)
RS232
FUNCTIONAL PROPERTIES
Protocol Modes FEIG ISO HOST (Advanced Protocol Frame)
Buffered Read Mode Scan Mode (RS232, USB: HID Mode)
Supported Transponder Types EPC Class 1 Generation 2
Signaller 1 LED (multi-colour red and green)
FEIG ELECTRONIC GmbH Page 13 of 21 Integration Manual M21112-1e-
ISO 18000-6-C (Upgrade Code required)
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
Further Features Anticollision (max. 10 Transponders)
RSSI Temperature Monitoring*
AMBIENT CONDITIONS
Temperature Range
Operation
Storage
-25 °C to +55 °C
-25 °C to +85 °C
Humidity 5 % to 95 % non-condensing
APPLICABLE STANDARDS
Radio Regulation
Europe
USA
Canada
EN 302 208 FCC 47 CFR Part 15 IC RSS-Gen, RSS-210
EMC EN 301 489 Vibration EN 60068-2-6
10 Hz bis 150 Hz: 0,075 mm / 1 g
Shock EN 60068-2-27
Accelleration 30 g
FEIG ELECTRONIC GmbH Page 14 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
* Caution: Overheating of the device may result in performance losses. It is recommended to activate the RF of the reader only if there is a transponder in the detection range of an antenna.
FEIG ELECTRONIC GmbH Page 15 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
7. Radio Approvals
7.1. Europe (CE)
When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99.
Equipment Classification according to ETSI EN 301 489: Class 2
FEIG ELECTRONIC GmbH Page 16 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
7.2. Declaration of Conformity
FEIG ELECTRONIC GmbH Page 17 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan
®
UHF
Integration
ID ISC.MRMU102-A
FEIG ELECTRONIC GmbH Page 18 of 21 Integration Manual M21112-1e-
ID-B.docx
OBID i-scan ® UHF
Integration
ID ISC.MRMU102-A
FEIG ELECTRONIC GmbH
Page 19 of 21
Integration Manual M21112-1e-
ID-B.docx
Product name: ID ISC.MRMU102-A
Reader name: ID ISC.MRMU102-A
FCC ID:
IC:
PJMMRU102
6633A-MRM102
Notice for USA and
Canada
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under
Federal communications Commission Rules permitting the operation of this device.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Le présent appareil est conforme aux CNR d'Industrie Canada appli­cables aux appareils radio exempts de licence. L'exploitation est auto­risée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonc­tionnement.
7.3. USA (FCC) and Canada (IC)
7.3.1. USA (FCC) and Canada (IC) warning notices
Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
Loading...
+ 44 hidden pages