Feig Electronic LRM1002 User Manual

Test report no. 17011006 Page 1 of 1
FCC ID: PJMLRM1002
FCC Title 47 CFR Part 15
Date of issue: 2017-10-02
Date: 2017-09-07
Created: P9 Controlled: P4 Released: P1
Vers. no. 1.17
m. dudde hochfrequenz-technik
GmbH & Co. KG
Rottland 5a
51429 Bergisch Gladbach/ Germany
Tel: +49 2207-96890
Fax +49 2207-968920
Annex acc. to FCC Title 47 CFR Part 15
relating to
FEIG ELECTRONIC GmbH
ID ISC.LRM1002 with
ID ISC.ANT.Mux and
ID ISC.ANT800/600-DA
Annex no. 5
User Manual
Functional Description
Title 47 - Telecommunication
Part 15 - Radio Frequency Devices
Subpart C – Intentional Radiators
ANSI C63.4-2014
ANSI C63.10-2013
ID ISC.LRM1002-E
Long Range Reader Modul
INTEGRATIONSANLEITUNG
final – public (B) 2014-05-14 – M21110-2d-ID-B.docx
(Deutsch)
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 2 von 24
M21110-2d-ID-B.docx
Hinweis
Copyright 2012-2014 by
FEIG ELECTRONIC GmbH Lange Straße 4 D-35781 Weilburg Tel.: +49 6471 3109-0
http://www.feig.de
Alle früheren Ausgaben verlieren mit dieser Ausgabe ihre Gültigkeit. Die Angaben in diesem Dokument können ohne vorherige Ankündigung geändert werden.
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten.
Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung für die Richtigkeit und Vollständigkeit der An­gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht für Folgeschäden auf Grund fehlerhafter oder unvollständiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bemü­hungen nie vollständig vermeiden lassen, sind wir für Hinweise jederzeit dankbar.
Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingun­gen aus. FEIG ELECTRONIC GmbH übernimmt weder Gewähr für die einwandfreie Funktion in system­fremden Umgebungen, noch für die Funktion eines Gesamtsystems, welches die in diesem Dokument be­schriebenen Geräte enthält.
FEIG ELECTRONIC weist ausdrücklich darauf hin, dass die in diesem Dokument beschriebenen Geräte nicht für den Einsatz mit oder in medizinischen Geräten oder für Geräte für lebenserhaltende Maßnahmen konzipiert sind, bei denen ein Fehler eine Gefahr für menschliches Leben oder für die gesundheitliche Un­versehrtheit zur Folge haben kann. Der Applikationsdesigner ist dafür verantwortlich geeignete Maßnahmen zu ergreifen um Gefahren, Schäden oder Verletzungen zu vermeiden.
FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthal­tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte.
OBID® und OBID i-scan® ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 3 von 24
M21110-2d-ID-B.docx
Content
1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen 4
2 Leistungsmerkmale der Reader ID ISC.LR1002-E 5
2.1 Leistungsmerkmale .................................................................................................... 5
2.2 Verfügbare Readervarianten ...................................................................................... 5
3 Montage und Anschluss 6
3.1 Montage ID ISC.LRM1002-E ....................................................................................... 6
3.2 Anschlussklemmen .................................................................................................... 8
3.2.1 Antennenanschluss .................................................................................................. 9
3.2.1.1 Anschluss eines ID ISC.DAT (Dynamic Antenna Tuning Board) ................... 10
3.2.2 Versorgungsspannung ........................................................................................... 11
3.2.3 Optokoppler Eingang (X5 / IN1) ............................................................................. 12
3.2.4 Relais (X6 / REL1) ................................................................................................. 14
3.2.5 Ausgang 24V (X5 / VIN, GND)......................................................................... 15
3.3 Schnittstellen ............................................................................................................ 16
3.3.1 RS232-Schnittstelle X4 .......................................................................................... 16
3.3.2 USB – Schnittstelle X11 (Host Kommunikation) ..................................................... 17
3.3.3 Ethernet-Schnittstelle an X3 (10/100 Base-T) ........................................................ 18
4 Bedien- und Anzeigeelemente 19
4.1 LEDs .......................................................................................................................... 19
5 Funkzulassungen 20
5.1 Europa (CE) ............................................................................................................... 20
5.2 USA (FCC) und Kanada (IC) ..................................................................................... 21
5.3 Label Information Reader ID ISC.LR1002-E ............................................................ 22
5.3.1 USA (FCC) and Canada (IC) approved antennas ................................................... 22
6 Technische Daten 23
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 4 von 24
M21110-2d-ID-B.docx
1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
Das Gerät darf nur für den vom Hersteller vorgesehenen Zweck verwendet werden. Die Bedienungsanleitung ist zugriffsfähig aufzubewahren und jedem Benutzer auszuhändigen. Unzulässige Veränderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen,
die nicht vom Hersteller des Gerätes verkauft oder empfohlen werden, können Brände, elektri­sche Schläge und Verletzungen verursachen. Solche Maßnahmen führen daher zu einem Ausschluss der Haftung und der Hersteller übernimmt keine Gewährleistung.
Für das Gerät gelten die Gewährleistungsbestimmungen des Herstellers in der zum Zeitpunkt
des Kaufs gültigen Fassung. Für eine ungeeignete, falsche manuelle oder automatische Ein­stellung von Parametern für ein Gerät bzw. ungeeignete Verwendung eines Gerätes wird keine Haftung übernommen.
Reparaturen dürfen nur vom Hersteller durchgeführt werden. Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gerät dürfen nur von Elekt-
rofachkräften mit einschlägiger Ausbildung erfolgen.
Alle Arbeiten am Gerät und dessen Aufstellung müssen in Übereinstimmung mit den nationa-
len elektrischen Bestimmungen und den örtlichen Vorschriften durchgeführt werden.
Beim Arbeiten an dem Gerät müssen die jeweils gültigen Sicherheitsvorschriften beachtet wer-
den.
Vor Berührung der Platinen ist stets die Spannungsversorgung abzuschalten und durch Nach-
messen sicherzustellen, dass das Gerät spannungslos ist. Das Verlöschen einer Betriebsan­zeige ist kein Indikator dafür, dass das Gerät vom Netz getrennt und spannungslos ist.
Besonderer Hinweis für Träger von Herzschrittmachern:
Obwohl dieses Gerät die zulässigen Grenzwerte für elektromagnetische Felder nicht über­schreitet, sollten Sie einen Mindestabstand von 25 cm zwischen der angeschlossenen Antenne und Ihrem Herzschrittmacher einhalten und sich nicht für längere Zeit in unmittelbarer Nähe des Geräts bzw. der Antenne aufhalten.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 5 von 24
M21110-2d-ID-B.docx
Reader
Beschreibung
ID ISC.LRM1002-E
Modulvariante mit RS232 / USB / LAN-Interface
ID ISC.LR1002-E
Gehäusevariante mit RS232 / USB / LAN-Interface
2 Leistungsmerkmale der Reader ID ISC.LR1002-E
2.1 Leistungsmerkmale
Der Reader ist für das Lesen von passiven Datenträgern, sogenannten „Smart Labels“, mit einer Betriebsfrequenz von 13,56 MHz entwickelt. Zum Betrieb ist es notwendig eine geeignete externe Antenne an dem Anschluss „ANT1“ anzuschließen.
2.2 Verfügbare Readervarianten
Folgende Readervarianten sind z.Z. verfügbar:
Tabelle 1: Verfügbare Readervarianten
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 6 von 24
M21110-2d-ID-B.docx
120
110
ø 4,5 mm*
160
155
80
ø 4,5 mm*
ø 4,5 mm*
5
ø 4,5 mm
155
ø 4,5 mm
5
4
29
V3
V2 V1
V4
NO
NC
COM
TxD
RxD
GND
GND
VIN
GND
VIN
IN -
IN +
X1
X5
X4
X6
X11
X3
ANT1
Abbildung 1 Maßzeichnung des Reader-Moduls mit Montageplatte
3 Montage und Anschluss
3.1 Montage ID ISC.LRM1002-E
Das Reader-Modul ist für die Montage auf einem Kühlkörper konzipiert. Für die Befestigung befin­det sich in den vier Ecken der Trägerplatte jeweils eine Bohrung mit dem 4,5 mm (siehe Abbil­dung 1)
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 7 von 24
M21110-2d-ID-B.docx
Für die Ausnutzung der vollen Leistungsfähigkeit des Reader-Moduls sollte der verwendete Kühl­körper einen Wärmewiderstand R
von maximal 2,0 K/W besitzen. Bei der Montage des Reader-
ThK
Moduls auf den Kühlkörper ist auf einen möglichst geringen Wärmeübergangswiderstand zwischen Trägerplatte und Kühlkörper zu achten. Die Verwendung von Wärmeleitpaste wird empfohlen.
Bei korrekt abgestimmter Antenne und ausreichender Luftkonvektion entlang der Montageplatte kann der ID ISC.LRM1002-E auch ohne zusätzlichen Kühlkörper bis zu einer Leistung von 2 W betrieben werden. Hierbei ist jedoch zu beachten, dass eine Verstimmung der Antenne zu einer zusätzlichen Erwärmung des Readers führt. In diesem Falle regelt der Reader seine Ausgangsleis­tung zurück bis die obere Grenztemperatur seiner Endstufe wieder unterschritten wird.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 8 von 24
M21110-2d-ID-B.docx
Abbildung 2 Anschlussklemmen des Readers
3.2 Anschlussklemmen
Abbildung 2 zeigt die Anschlussklemmen und Bedienelemente des ID ISC.LR(M)1002-E.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 9 von 24
M21110-2d-ID-B.docx
Klemme
Beschreibung
ANT1
Anschluss der externen Antenne (Eingangsimpedanz 50)
3.2.1 Antennenanschluss
Zum Anschluss der Antenne an den ID ISC.LRM1002 befindet sich auf der Leiterplatte die SMA­Buchse "ANT1".
Eine externe LED kann zusätzlich über den Antennenanschluss mit 6,5 V versorgt werden. Diese kann per Software-Konfiguration aktiviert werden. Die maximale Stromaufnahme darf dabei 20mA nicht überschreiten.
Es ist nicht möglich damit das Antennen Tuning Board ID ISC.DAT zu versorgen!
Siehe: Anschluss eines ID ISC.DAT (Dynamic Antenna Tuning Board) Das maximale Anzugsdrehmoment der SMA-Buchse beträgt 0,45 Nm.
Achtung: Höhere Anzugsdrehmomente führen zur Zerstörung der Buchse.
Tabelle 2: Anschluss der externen Antenne
Hinweise:
Das Stehwellenverhältnis VSWR der Antenne sollte den Wert 1,3 nicht überschreiten. Für das Erreichen optimaler Lesereichweiten müssen die Koaxialkabel zwischen
Reader und Antenne definierte Längen haben. Für alle Antennen von der Firma FEIG ELECTRONIC GmbH und für alle Antennen welche mit den Abgleichplatinen (z.B. ID ISC.DAT, ID ISC.MAT-B und ID ISC.MAT-S) von FEIG ELECTRONIC GmbH aufgebaut sind ist die optimale Länge des Koaxialkabels 1,35 m (Artikel Nr. 1654.004.00.00, Be­zeichnung ID ISC.ANT.C-B). Siehe auch Montageanleitung Power Splitter ID ISC.ANT.PS-B und ID ISC.ANT.MUX.
Die optimale Betriebsgüte der Antenne sollte im Bereich QB = 10...30 liegen. Zur Er-
mittlung der Betriebsgüte muss die Antenne mit einer 50-Quelle, z.B. einem Net­work Analyzer oder einem Frequenzgenerator, versorgt werden.
Zur Vermeidung extern eingekoppelter Störungen muss die Antennenzuleitung dem
beigefügten EMV-Ringkernferrit 28 mm x 20 mm versehen werden. Hierzu ist die Antennenzuleitung mindestens vier mal, eng anliegend durch den EMV­Ringkernferrit zu führen. Der Abstand zwischen Readeranschluss ANT1 und Ringkern sollte dabei maximal 10 cm betragen (siehe Abbildung 3).
Beim Anschluss der Antenne ist darauf zu achten, dass diese die zulässigen Grenz-
werte der nationalen Vorschriften bezüglich Funkanlagen nicht überschreitet.
Abbildung 3 Antennenkabel mit EMV-Ringkernferrit
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 10 von 24
M21110-2d-ID-B.docx
3.2.1.1 Anschluss eines ID ISC.DAT (Dynamic Antenna Tuning Board)
Um Antennen mit einem ID ISC.DAT Tuning Board zu betreiben wird zum tunen eine DC Span­nung benötigt. Diese DC Spannung muss über einen Powersplitter (ID ISC.ANT.PS-B) oder einem Antennen Multiplexer (ID ISC.ANT.MUX) zur Verfügung gestellt werden.
Abbildung 4 zeigt die DC Spannungsversorgung des ID ISC.DAT mit einem Powersplitter.
Abbildung 4: DC Spannungsversorgung des ID ISC.DAT mit einem ID ISC.ANT-PS-B
Abbildung 5 zeigt die DC Spannungsversorgung des ID ISC.DAT mit einem Antennen Multiplexer.
Abbildung 5: DC Spannungsversorgung des ID ISC.DAT mit einem ID ISC.ANT.MUX.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 11 von 24
M21110-2d-ID-B.docx
Klemme
Kurzzeichen
Beschreibung
X1
VIN
Vcc – Versorgungsspannung +24 V DC /
X1
GND
Ground – Versorgungsspannung
GND
VIN
X1
X5
3.2.2 Versorgungsspannung
Der Reader darf nur von einer Spannungsversorgung gemäß EN 60950-1 Kapitel 2.5 Stromquel­len begrenzter Leistung (LPS) oder mit einen nach NEC Class 2/LPS zertifizierten Netzteil versorgt werden.
Die Versorgungsspannung von 24 V ist an der Klemme X1 anzuschließen.
Tabelle 3: Pinbelegung Versorgungsspannung
Hinweis:
Abbildung 6: Position der Klemme X1 für die Versorgungsspannung
Eine Verpolung der Versorgungsspannung kann zur Zerstörung des Gerätes führen. Zur Reduzierung von Störungen (Noise) kann die Versorgungsspannungszuleitung
mit einem EMV-Ringkernferrit 28 mm x 20 mm versehen werden. Hierzu ist das Kabel mindestens fünf mal, eng anliegend durch den EMV-Ringkernferrit zu schlei­fen. Der Abstand zwischen Readeranschluss und Ringkern sollte dabei maximal 10 cm betragen.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 12 von 24
M21110-2d-ID-B.docx
GND
VIN
IN -
IN +
X5
3.2.3 Optokoppler Eingang (X5 / IN1)
Der Optokoppler Eingang ist auf dem Klemmleiste X5 zugänglich.
Abbildung 7: Digitaler Eingang an der Klemmleiste X5
Der Optokoppler an der Klemmleiste X5 ist galvanisch von der Reader-Elektronik getrennt und muss daher mit einer externen 24 VDC Spannung versorgt werden. Die externe VCC Spannung kann jedoch auch über die Anschlüsse VIN (24VDC) und GND (Ground) von dem Reader zur Verfügung gestellt werden. Siehe: 3.2.5 Ausgang 24V (X5 /
VIN, GND)
Abbildung 8: Mögliche externe Spannungsversorgung der Optokoppler am Anschluss X5
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 13 von 24
M21110-2d-ID-B.docx
Abbildung 9: Mögliche interne Spannungsversorgung der Optokoppler am Anschluss X5
Die Eingangs-LED des Optokopplers ist intern mit einem Serienwiderstand von 3,74 k beschaltet um den Eingangsstrom auf max. 6 mA zu begrenzen.
Hinweise:
Der Eingang ist für eine maximale Eingangsspannung von 24 V und einem Ein-
gangsstrom von maximal 6 mA ausgelegt.
Verpolung oder Überlastung des Eingangs kann zu dessen Zerstörung führen. Die gleichzeitige Verwendung der internen und einer externen Versorgungsspan-
nung kann zur Zerstörung des Gerätes führen.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 14 von 24
M21110-2d-ID-B.docx
V4
NO
NC
COM
X4
X6
3.2.4 Relais (X6 / REL1)
Als Relaisausgang stehen ein Wechsler zur Verfügung. Die jeweiligen Kontakte stehen an den Klemme X6 zur Verfügung. Die Ausgänge sind galvanisch von der Reader-Elektronik getrennt und müssen daher mit einer externen Spannung versorgt werden. Die externe Spannung kann auch von dem Anschluss X5 VIN und GND zur Verfügung gestellt werden. Siehe: Ausgang 24V (X5 /
VIN, GND)
Abbildung 10: Relais Ausgänge an der Klemmleiste X6
Abbildung 11: Mögliche externe Beschaltung der Relaisausgänge mit
externer Spannungsversorgung
Hinweise:
Der Relaisausgang ist für max. 24 V / 1 A ausgelegt. Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Im Falle einer
induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu schützen.
Die gleichzeitige Verwendung der internen und einer externen Versorgungsspannung
kann zur Zerstörung des Gerätes führen.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 15 von 24
M21110-2d-ID-B.docx
GND
VIN
IN -
IN +
X5
3.2.5 Ausgang 24V (X5 / VIN, GND)
Am Ausgang VIN/GND stehen 24V für die externe Spannungsversorgung des digitalen Ein­gangs sowie des Relais zur Verfügung. Die maximale Stromentnahme darf 1A nicht überschreiten.
Abbildung 12: Mögliche externe 24V Spannungsversorgung
Hinweise:
Die an diesem Ausgang entnommene Leistung für die externe Beschaltung muss bei
der Dimensionierung des Netzteils zusätzlich zu der typischen Reader Leistung mit berücksichtigt werden.
Die interne 24V Versorgungsspannung an X5 ist nicht über eine Sicherung abge-
sichert.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 16 von 24
M21110-2d-ID-B.docx
TxD
RxD
GND
X4
X6
Kurzzeichen
Beschreibung
TxD
RS232 – (Transmit)
RxD
RS232 – (Receive)
GND
RS232 – (Ground)
3.3 Schnittstellen
3.3.1 RS232-Schnittstelle X4
Der Anschluss der RS232-Schnittstelle erfolgt über X4. Die Übertragungsparameter können per Softwareprotokoll konfiguriert werden.
Abbildung 13: Anschlussbelegung X4 (RS232-Schnittstelle)
Tabelle 4 Belegung RS232-Schnittstelle
Abbildung 14: Verdrahtungsbeispiel für den Anschluss der RS232-Schnittstelle
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 17 von 24
M21110-2d-ID-B.docx
X2
Pin-Nr.
1
Schirm
USB Kabel - Schirm
2
GND
3
USB-D PLUS
4
USB-D MINUS
5
VCC
+ 5 V DC 5 %
3541.000.00
ID CAB.USB-B Cable for Interface USB/JST PH
Abbildung 15: USB-Schnittstelle für Host Kommunikation an X11
Abbildung 16 Stecker „JST PH“
3.3.2 USB – Schnittstelle X11 (Host Kommunikation)
Der Anschluss der USB-Schnittstelle erfolgt über Buchse X11. Die Datenrate des Readers ist auf 12 Mbit beschränkt (USB Full Speed).
Nachfolgende Abbildung 16 und Tabelle zeigt die Belegung der Stecker X11 (5pol.) vom Typ “JST PH” RM 2 mm (stehend).
Optional kann folgendes USB-Anschlusskabel verwendet werden:
Hinweis: Die maximale Länge des USB-Kabels darf 5 m betragen. Längere Kabel sind nicht erlaubt.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 18 von 24
M21110-2d-ID-B.docx
Netzwerk
Adresse
IP-Adresse
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
DHCP
AUS
X3
Abbildung 17: LAN Schnittstelle für Host Kommunikation
3.3.3 Ethernet-Schnittstelle an X3 (10/100 Base-T)
Der Reader verfügt über eine integrierte 10/100 Base-T Netzwerkschnittstelle mit Standard RJ-45­Anschluss. Der Anschluss erfolgt über X3 und hat eine automatische „Crossover Detection“ ent- sprechend dem 1000 Base-T Standard.
Bei einer strukturierten Verkabelung sollten mindestens Kabel der Kategorie CAT5 verwendet wer­den. Dies garantiert einen problemlosen Betrieb bei 10 Mbps oder 100 Mbps.
Voraussetzung für den Einsatz des TCP/IP-Protokolls ist, dass jedes Gerät am Netzwerk über eine eigene IP-Adresse verfügt. Alle Reader verfügen über eine werksseitig voreingestellte IP-Adresse.
Tabelle 5: Werkskonfiguration der Ethernet-Schnittstelle
Hinweis:
Der Reader verfügt über eine DHCP-fähige TCP/IP Schnittstelle, die werkseitig aus-
geschaltet ist.
Es wird empfohlen ein abgeschirmtes STP (shielded twisted pair) CAT5 Kabel zu
verwenden.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 19 von 24
M21110-2d-ID-B.docx
Kurzzeichen
Beschreibung
LED V1 (grün)
"RUN-LED 1"
- Signalisiert den ordnungsgemäßen Ablauf der internen Reader-Software (DSP)
- Leuchtet während der Reader-Initialisierung nach dem Ein- schalten bzw. nach einem Reset.
LED V2 (blau)
Diagnose 1: RF-Kommunikation / EEPROM-Status
- Signalisiert durch ein kurzes Blinken die fehlerfreie Kommuni- kation mit einem Transponder auf der RF-Schnittstelle
- Blinkt abwechselnd mit V1 nach dem Reset im Anschluss an ein Software-Update
- Blinkt abwechselnd mit V1 falls nach einem Reset ein Daten- fehler beim Lesen der Parameter auftrat
LED V3 (gelb)
Diagnose 2: Host-Kommunikation
- Signalisiert durch ein kurzes Blinken das Senden eines Proto­kolls an den Host auf der RS232/USB/LAN-Schnittstelle
LED V4 (rot)
Diagnose 4: RF-Warnung
- Leuchtet bei einem Fehler im RF-Teil des Readers. Der Feh- lertyp kann per Software über die RS232/USB/LAN­Schnittstelle ausgelesen werden
4 Bedien- und Anzeigeelemente
4.1 LEDs
Tabelle 6 zeigt die Konfiguration der LEDs.
Tabelle 6: Konfiguration der LEDs
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 20 von 24
M21110-2d-ID-B.docx
5 Funkzulassungen
5.1 Europa (CE)
Die Funkanlage entspricht, bei bestimmungsgemäßer Verwendung den grundlegenden Anforde­rungen des Artikels 3 und den übrigen einschlägigen Bestimmungen der R&TTE Richtlinie 1999/5/EG vom März 99.
Equipment Classicfication gemäß ETSI EN 301 489: Class 2 SRD
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 21 von 24
M21110-2d-ID-B.docx
Product name:
ID ISC.LRM1002-E
Reader name:
ID ISC.LRM1002-E
FCC ID:
IC:
PJMLRM1002
6633A-LRM1002
Notice for USA and
Canada
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under
Federal communications Commission Rules permitting the operation of this device.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Le présent appareil est conforme aux CNR d'Industrie Canada appli­cables aux appareils radio exempts de licence. L'exploitation est auto­risée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonc­tionnement.
5.2 USA (FCC) und Kanada (IC)
Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand­ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to en­sure that only certified systems are deployed in the United States / Canada.
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 22 von 24
M21110-2d-ID-B.docx
5.3 Label Information Reader ID ISC.LRM1002-E
Die folgende Information muss auf dem Gehäuse von außen sichtbar sein:
5.3.1 USA (FCC) and Canada (IC) approved antennas
This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with maxi­mum permission gain and required antenna impedance for each antenna type indicated. Antenna types, not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonc­tionner avec les types d’antenne ’énoncé ci-dessus et ayant un gain admissible maximal et
l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,
ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur
Following antennas are approved by FCC according FCC Part 15 and IC Canada according RS210
ID ISC.ANT310/310-A (magnetic antenna) ID ISC.ANTS370/270-A (magnetic antenna) ID ISC.ANT1300/680-A (magnetic antenna)
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 23 von 24
M21110-2d-ID-B.docx
Mechanische Daten
Abmessungen ( B x H x T )
160 x 120 x 35 mm³
Gewicht
Approx. 0,35 kg
Elektrische Daten
Spannungsversorgung
24 V 15 % Noise Ripple : max. 150 mV
Leistungsaufnahme
max. 16 VA
Betriebsfrequenz
13,56 MHz
Sendeleistung
1 W – 5 W (per Software in 1 W Schritten einstellbar)
Modulationsgrad
14%
Antennenanschluss
SMA Buchse (50 , SWR 1.3)
Gleichspannung auf
der Antennenleitung
6,5 V (max. 20mA)
Diagnoseoptionen
Interne Impedanzüberwachung interne Temperaturüberwachung
Ausgänge
1 Relais (NO)
24 V / 1A
Eingänge
1 Optokoppler
24 V / 6 mA
Schnittstellen
- RS232
- USB
- Ethernet (TCP/IP)
Protokoll Modi
- FEIG ISO HOST
- BRM (Datenfilterung und Datenpufferung)
- Scan Mode
- Notification Mode
6 Technische Daten
OBID i-scan® HF
Integration
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Seite 24 von 24
M21110-2d-ID-B.docx
Unterstützte Transponder
ISO15693, ISO18000-3 MODE 1
(EM HF ISO Chips, Fujitsu HF ISO Chips, KSW Sensor Chips, IDS Sensor Chips Infineon my-d, NXP I-Code, STM ISO Chips, TI Tag-it)
ISO18000-3M3 (Upgrade Code required)
Signalgeber, optisch
4 LEDs zur Diagnose des Betriebszustandes
Umgebungsbedingungen
Temperaturbereich
Betrieb Lagerung
-20°C bis +55°C
-25°C bis +85°C
Luftfeuchtigkeit
5% - 80%, nicht kondensierend
Vibration
EN60068-2-6 10 Hz bis 150 Hz : 0,075 mm / 1 g
Schock
EN60068-2-27 Beschleunigung : 30 g
Zulassung
Zulassung Funk
Europa USA
EN 300 330 FCC 47 CFR Part 15
EMV
EN 301 489
Sicherheit
Elektrische Sicherheit Human Exposure
EN 60950 EN 50364
OBID i-scan
®
ID ISC.ANT.MUX
MONTAGE
INSTALLATION
Antenna Multiplexer
(deutsch / english)
final public (B) 2003-10-28 M30201-1de-ID-B.doc
OBID i-scan
D E U T S C H
E N G L I S H
Montage ID ISC.ANT.MUX
deutsche Version ab Seite 3
english version from page 21
FEIG ELECTRONIC GmbH Seite 2 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
Hinweis
Copyright 2003 by
FEIG ELECTRONIC GmbH Lange Straße 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0
http://www.feig.de
Alle früheren Ausgaben verlieren mit dieser Ausgabe ihre Gültigkeit. Die Angaben in diesem Dokument können ohne vorherige Ankündigung geändert werden.
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten.
Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung für die Richtigkeit und Vollständigkeit der An­gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht für Folgeschäden auf Grund fehlerhafter oder unvollständiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bemü­hungen nie vollständig vermeiden lassen, sind wir für Hinweise jederzeit dankbar.
D E U T S C H
Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingun­gen aus. FEIG ELECTRONIC GmbH übernimmt keine Gewähr für die einwandfreie Funktion in systemfrem­den Umgebungen.
FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthal­tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte.
OBID i-scan
ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH
Das Zeichen „)“ weist auf Erweiterungen bzw. Änderungen gegenüber der Vorgängerversion hin.
FEIG ELECTRONIC GmbH Seite 3 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
Inhalt
1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen 5
2. Leistungsmerkmale des 8fach Antennenmultiplexers ID ISC.ANT.MUX 6
D E U T S C H
2.1. Leistungsmerkmale.......................................................................................................... 6
2.2. Lieferumfang..................................................................................................................... 6
3. Anschluss und Montage 7
3.1. Montage des Gehäuses.................................................................................................... 7
3.2. Anschlussklemmen und Anschlussbuchsen ................................................................. 8
3.3. X1: Spannungsversorgung.............................................................................................. 8
3.4. X2: Eingang (Optokoppler) .............................................................................................. 9
3.5. IN1-2: Readeranschluss................................................................................................. 10
3.6. OUT1-8: Antennenanschluss......................................................................................... 10
4. Bedien- und Anzeigeelemente 11
4.1. LEDs................................................................................................................................ 11
4.2. DIP-Schalter S1............................................................................................................... 12
4.2.1. Einstellen der Modi....................................................................................................12
4.2.2. Adresseinstellung im HF-Communikation Control Mode ........................................... 12
4.2.3. Einstellung Single- oder Dual-Mode im Extern-Trigger Mode .................................... 13
4.2.4. Einstellung Anzahl Ausgänge im Extern-Trigger Mode.............................................. 13
4.3. Jumper JP1- 8................................................................................................................. 14
4.4. Jumper JP11 – JP18....................................................................................................... 15
4.5. Jumper JP19 und JP20 ................................................................................................. 15
5. Inbetriebnahme 16
5.1. HF-Communikation Control Mode................................................................................. 16
5.2. Extern-Trigger Mode ...................................................................................................... 17
ANHANG A: Technische Daten 18
FEIG ELECTRONIC GmbH Seite 4 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
Das Gerät darf nur für den vom Hersteller vorgesehenen Zweck verwendet werden.
Die Bedienungsanleitung ist zugriffsfähig aufzubewahren und jedem Benutzer auszuhändigen.
Unzulässige Veränderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen,
die nicht vom Hersteller des Gerätes verkauft oder empfohlen werden, können Brände, elektri­sche Schläge und Verletzungen verursachen. Solche Maßnahmen führen daher zu einem Ausschluss der Haftung und der Hersteller übernimmt keine Gewährleistung.
Für das Gerät gelten die Gewährleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gültigen Fassung. Für eine ungeeignete, falsche manuelle oder automatische Ein­stellung von Parametern für ein Gerät bzw. ungeeignete Verwendung eines Gerätes wird kei­ne Haftung übernommen.
Reparaturen dürfen nur vom Hersteller durchgeführt werden.
Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gerät dürfen nur von E-
lektrofachkräften mit einschlägiger Ausbildung erfolgen.
Vor dem Öffnen des Gerätes ist stets die Versorgungsspannung abzuschalten und durch Nachmessen sicherzustellen, daß das Gerät spannungslos ist. Das Verlöschen einer Be­triebsanzeige ist kein Indikator dafür, daß das Gerät vom Netz getrennt und spannungslos ist.
Alle Arbeiten am Gerät und dessen Aufstellung müssen in Übereinstimmung mit den nationa- len elektrischen Bestimmungen und den örtlichen Vorschriften durchgeführt werden.
D E U T S C H
FEIG ELECTRONIC GmbH Seite 5 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
2. Leistungsmerkmale des 8fach Antennenmultiplexers ID ISC.ANT.MUX
2.1. Leistungsmerkmale
D E U T S C H
Der 8-fach Antennenmultiplexer ID ISC.ANT.MUX eignet sich zum Schalten von RFID Antennen mit einer Betriebsfrequenz von 13,56 MHz. Mit einem ID ISC.ANT.MUX können mehrere Einzelantennen (Basisantennen) oder Gateantennen (Basis- und Ergänzungsantennen) mit nur einem Reader betrieben werden. Alle acht Ausgänge des Antennenmultiplexers können über Jumpereinstellungen jedem der beiden Eingänge zugeordnet werden.
Es ist möglich, mehrere ID ISC.ANT.MUX zu kaskadieren und so die Anzahl der möglichen Antennenanschlüsse zu erhöhen. Dazu können die Antennenmultiplexer über DIP­Schalterstellungen adressiert werden.
2.2. Lieferumfang
Folgende Komponenten sind im Lieferumfang enthalten:
y 8-fach Antennenmultiplexer ID ISC.ANT.MUX
y 8 x Dichtverschluss für M16 Kabelverschraubung
y Montageanleitung
FEIG ELECTRONIC GmbH Seite 6 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
3. Anschluss und Montage
3.1. Montage des Gehäuses
Der Antennenmultiplexer ist für die Montage auf Wänden, auch im Freien, konzipiert. Zur Wand­befestigung befinden sich in den Ecken des Gehäuses entsprechende Durchbrüche (siehe Bild 1).
180
165
5
ø
x
4
D E U T S C H
95
110
Bild 1: Masse und Befestigungsbohrungen
Die Kabeldurchführungen sind M16 x 1,5 Kabelverschraubungen für einen Klemmbereich von 4,5 mm bis 10 mm.
FEIG ELECTRONIC GmbH Seite 7 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
3.2. Anschlussklemmen und Anschlussbuchsen
In Bild 2 sind alle Anschlussklemmen, Buchsen, Bedienteile und Anzeigeteile dargestellt.
D E U T S C H
X2
X1
JP20
JP19
OUT 1OUT 2OUT 3OUT 4
JP14 JP13 JP12 JP11
12345678
S1
LED1 LED2 LED3
X3
LEDout5 LEDout6 LEDout7 LEDout8
JP15 JP16 JP17 JP18
ON
OFF
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
LEDout1LEDout2LEDout3LEDout4
OUT 8OUT 7OUT 6OUT 5
IN 1
IN 2
Bild 2: Anschlussklemmen, Buchsen und Bedienelemente
3.3. X1: Spannungsversorgung
Die Spannungsversorgung wird über X1 angeschlossen. Dabei ist die Polung gemäß Bild 3 anzu­klemmen. Der Antennenmultiplexer arbeitet bei einer Gleichspannung von 12V bis 24V.
X1
12-24V DC
GND
Bild 3: Anschluss Versorgungsspannung
FEIG ELECTRONIC GmbH Seite 8 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
3.4. X2: Eingang (Optokoppler)
Der digitale Eingang an Klemmleiste X2 dient zum triggern des Multiplexers im Extern-Trigger Mode. Der Optokopplereingang ist galvanisch vom Antennenmultiplexer getrennt und muss daher mit einer externen Gleichspannung versorgt werden. Die Eingangs-LED des Optokopplers ist in­tern mit einem Serienwiderstand beschaltet, dessen Größe über die Jumper JP11 und JP12 ein­stellbar ist (s. Bild 4). Der Eingangsstrom sollte zwischen 10 mA und 20 mA liegen. Je nach Ein­gangsspannung sind Jumpereinstellungen gemäß Tab. 1 vorzunehmen.
Tab. 1: Jumpereinstellung für Optokopplereingang
D E U T S C H
ext. Spannung U
5 V – 8 V
8 V – 12 V
12 V – 24 V
ext
R
int
350
500
1,2 k
X2
JP20
JP19
JP19 JP20
gesetzt gesetzt
gesetzt offen
offen gesetzt
1,2 k
500
Bild 4: Eingang
Das Triggersignals an Eingang X2 muss innerhalb der in Bild 5 angegebenen Grenzwerte liegen. Bei hohen Schaltfrequenzen ist es sinnvoll, das Triggersignal und die Transponderprotokolle zu synchronisieren, um nicht während des Auslesens eines Transponders die Verbindung zwischen Reader und Transponder zu unterbrechen.
t
p
U
U
p
t
b
t
: 1 – 100 ms
b
: > ( tb + 1 ms )
t
p
: 5 – 24 V
U
p
DC
t
Bild 5: Signal für externen Trigger
FEIG ELECTRONIC GmbH Seite 9 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
3.5. IN1-2: Readeranschluss
Der Anschluss an einen Reader erfolgt über das Antennenkabel an die SMA-Buchsen IN1 und/oder IN2. Das maximale Anzugsdrehmoment der SMA-Buchsen beträgt 0,45 Nm. Die Koaxi­alkabel zum Readeranschluss sind jeweils durch die seitlichen Kabelverschraubungen zu führen (s. Bild 6).
D E U T S C H
Bild 6: Readeranschluss
Hinweis:
Für das Erreichen optimaler Lesereichweiten sollte das Koaxialkabel entweder kleiner 50 cm oder 7,20 m lang sein.
3.6. OUT1-8: Antennenanschluss
Die Antennen sind mit Koaxialkabel über die SMA-Buchsen OUT1-8 anzuschließen. Das maximale Anzugsdrehmoment der SMA-Buchsen beträgt 0,45 Nm. Die Anschlüsse an die SMA-Buchsen OUT1-4 sind durch die oberen Kabelverschraubungen und die Anschlüsse an OUT5-8 durch die unteren Kabelverschraubungen zu führen (s. Bild 7)
Bild 7: Antennenanschlüsse
FEIG ELECTRONIC GmbH Seite 10 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
4. Bedien- und Anzeigeelemente
4.1. LEDs
Die LEDs, die sich an den SMA-Buchsen OUT1-8 befinden (LEDout1-8), signalisieren, ob der ent­sprechende Kanal durchgeschaltet oder gesperrt ist. Im durchgeschalteten Zustand des Kanals leuchtet die jeweilige LED.
In Tab. 2 sind die Funktionen der LEDs LED1-3 aufgelistet:
Tab. 2: Funktion LED1-3
Kurzzeichen Farbe Beschreibung
LED1 rot Diagnose 1: „Kommunikations-LED“
D E U T S C H
HF-Communikation Control Mode:
- Blinkt auf, wenn der Multiplexer ein Signal vom Reader über die SMA­Buchse IN1 erhalten hat.
- Leuchtet, wenn Multiplexer Fehler am Ausgang detektiert hat.
Extern-Trigger Mode:
- Blinkt auf, wenn der Multiplexer einen gültigen Impuls über X2 erhalten hat.
LED2 grün Diagnose 2: „HF-LED“
Leuchtet, wenn ein HF-Signal an der SMA­Buchse IN1 anliegt.
LED3 grün „RUN-LED“:
Signalisiert durch Blinken (ca. 1 Hz) den ordnungsgemäßen Ablauf der internen Soft­ware.
FEIG ELECTRONIC GmbH Seite 11 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
4.2. DIP-Schalter S1
Über die DIP-Schalter S1 können die verschiedenen Multiplexermodi und Adressierungen einge­stellt werden. Nach einem Umstellen der DIP-Schalter muss ein Power-Up-Reset durchgeführt werden, indem die Versorgungsspannung kurz unterbrochen wird.
D E U T S C H
4.2.1. Einstellen der Modi
Die Einstellung der Modi erfolgt über die DIP-Schalter 1 und 2. In Tab. 3 sind die Einstellungen zusammengefasst.
Tab. 3: Einstellung der Modi

DIP-Schalter S1 Adresse

12345678
-- reserviert
-ON Extern-Trigger Mode
ON - HF-Communikation Control Mode
1
2
ON ON reserviert
4.2.2. Adresseinstellung im HF-Communikation Control Mode
Mit den DIP-Schaltern kann für den HF-Communikation Control Mode eine Adresseinstellung vor­genommen werden. Dabei wird über die DIP-Schalter 3 und 4 die Ebene sind die Einstellungen der Ebenen zusammengefasst:
Tab. 4: Adressierung im HF-Communikation Control Mode
DIP-Schalter S1 Adresse / Ebene
12345678
ON --- nicht genutzt
ON --ON Ebene 1
ON - ON - Ebene 2
ON -ONON Ebene 3
3
eingestellt. In Tab. 4
1
siehe 5.2. Extern-Trigger Mode
2
siehe 5.1. HF-Communikation Control Mode
3
siehe auch Handbuch H30701-#d-ID-B.doc
FEIG ELECTRONIC GmbH Seite 12 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
4.2.3. Einstellung Single- oder Dual-Mode im Extern-Trigger Mode
Im Extern-Trigger Mode kann der Multiplexer im Single- oder im Dual-Mode betrieben werden. Im Single-Mode ist immer nur ein Ausgang durchgeschaltet, im Dual-Mode zwei, je ein Ausgang für IN1 und IN2.
Der Dual-Mode wird durch Zuschalten der DIP-Schalter 3 und 4 aktiviert. Ansonsten ist der Single­Mode eingestellt (s. Tab. 5).
4.2.4. Einstellung Anzahl Ausgänge im Extern-Trigger Mode
Über die DIP-Schalter 5-8 wird die Anzahl der verwendeten Ausgänge im Single- bzw. Dual-Mode eingestellt:
Tab. 5: Einstellung Anzahl der Ausgänge im Single- und Dual-Mode
DIP-Schalter S1 Kanäle
12345678
Single-Mode
D E U T S C H
- ON -----ONKanal 1
- ON - - - - ON - Kanal 1-2
- ON - - - - ON ON Kanal 1-3
- ON - - - ON - - Kanal 1-4
- ON - - - ON - ON Kanal 1-5
- ON - - - ON ON - Kanal 1-6
- ON - - - ON ON ON Kanal 1-7
- ON - - ON - - - Kanal 1-8 Dual-Mode
- ON ON ON - - - ON Kanal 1+8
- ON ON ON - - ON - Kanal 1+8, 2+7
- ON ON ON - - ON ON Kanal 1+8, 2+7, 3+6
- ON ON ON - ON - - Kanal 1+8, 2+7, 3+6, 4+5
FEIG ELECTRONIC GmbH Seite 13 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
4.3. Jumper JP1- 8
Über die Jumper 1-8 können den Eingängen IN1 und IN2 die entsprechenden Ausgänge OUT1-8 zugewiesen werden (s. Bild 8).
OUTx
D E U T S C H
Bild 8: Zuweisung des Ausgangs OUTx
Bei nicht verwendeten Ausgängen ist die Stellung des entsprechenden Jumpers nicht von Bedeu­tung. In Tab. 6 sind 3 Beispiel aufgeführt:
Tab. 6 Beispiel Jumperstellung JP1-8
Jumperstellung Zuordnung
1
JPx
IN1 IN2
Die Jumper JP1-8 stehen alle auf Position 2-3.
Alle Ausgänge (OUT1-8) sind damit dem Eingang IN1 zugeordnet.
Die Jumper JP1-4 stehen auf Position 2-3, die Jum­per JP5-8 auf Position 1-2.
Damit sind die Ausgänge OUT1-4 dem Eingang IN1 und die Ausgänge OUT4-8 dem Eingang IN2 zuge­ordnet.
JP1, JP3, JP4 und JP6 stehen auf Position 2-3; JP2, JP5 und JP7 auf Position 1-2
Damit sind die Ausgänge OUT1, 3, 4, 6 dem Eingang IN1 und die Ausgänge OUT2, 5, 7 dem Eingang IN2 zugeordnet. Der Ausgang OUT8 ist keinem Eingang zugeordnet.
FEIG ELECTRONIC GmbH Seite 14 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
4.4. Jumper JP11 – JP18
Durch setzen der Jumper JP11 - JP18 wird dem entsprechenden Ausgang OUT1 – OUT8 eine DC-Offset von + 7V zugeschaltet. Der maximale Gleichstrom, der über die Ausgänge fließen darf, beträgt 100mA.
4.5. Jumper JP19 und JP20
Mit den Jumpern JP19 und JP20 wird der Eingangswiderstand des Optokopplereingangs an X2 eingestellt. In Tab. 1 (Kapitel 3.4. X2: Eingang (Optokoppler)) sind die möglichen Einstellungen aufgelistet.
D E U T S C H
FEIG ELECTRONIC GmbH Seite 15 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
5. Inbetriebnahme
5.1. HF-Communikation Control Mode
Im HF-Communikation Control Mode wird der Multiplexer über Protokolle vom Reader gesteuert.
D E U T S C H
Es ist kein zusätzliches Kabel zwischen Reader und Multiplexer notwendig. Die Protokolle sind im Handbuch H30701-#d-ID-B aufgeführt.
Durch die Kommunikation zwischen Reader und Multiplexer ist ein gezieltes Schalten bestimmter Ausgänge möglich.
Bild 9 zeigt ein einfaches Anwendungsbeispiel mit einem Multiplexer und vier Antennen. Folgende DIP-Schalterstellung ist dabei vorzunehmen (s. 4.2. DIP-Schalter S1):
Tab. 7: DIP-Schalterstellung
1 2 3 4 5 6 7 8
ON--ON----
12-24VDC
Antennen
OUT1-4
MUX
IN1
X1
50cm
Reader
Bild 9: Anwendungsbeispiel mit vier Antennen im HF-Communikation Control Mode
FEIG ELECTRONIC GmbH Seite 16 von 37 M30201-1de-ID-B.doc
OBID i-scan
Montage ID ISC.ANT.MUX
5.2. Extern-Trigger Mode
Im Extern-Trigger Mode wird der Multiplexer über den Eingang X2 gesteuert (s. 3.4. X2: Eingang (Optokoppler)). Dabei werden die eingestellten Ausgänge nacheinander in numerischer Reihenfol-
ge durchgeschaltet.
Die Jumperstellungen der Jumper JP19 und JP20 sowie die Pulsbreite des externen Triggersignal ist in Kap. 3.4. X2: Eingang (Optokoppler) beschrieben.
Bild 10 zeigt ein einfaches Anwendungsbeispiel mit einem Multiplexer und vier Antennen. Folgen­de DIP-Schalterstellung ist dabei vorzunehmen (s. 4.2. DIP-Schalter S1):
Tab. 8: DIP-Schalterstellung
1 2 3 4 5 6 7 8
-ON---ON--
D E U T S C H
12-24VDC
Antennen
OUT1-4
MUX
IN1
X2 X1
50cm
Reader
Bild 10: Beispielanwendung mit vier Antennen im Extern-Trigger Mode
FEIG ELECTRONIC GmbH Seite 17 von 37 M30201-1de-ID-B.doc
OBID i-scan

ANHANG A: Technische Daten

Mechanische Daten
Montage ID ISC.ANT.MUX
D E U T S C H
Abmessungen ( B x H x T )
Gewicht
Schutzart
Kabeldurchführung
Elektrische Daten
Spannungsversorgung
Leistungsaufnahme
Betriebsfrequenz
Dämpfung pro Kanal
max. zul. Schaltleistung
182 mm x 110 mm x 90 mm
ca. 550 g
IP65
12 x Kabelverschraubung M16 x 1,5
12 - 24 V DC
max. 4 W
13,56 MHz
max. 0,5 dB
10 W
RF-Anschlüsse
- 2 x Eingang
- 8 x Ausgang
RF Schalter
– Schaltgeschwindigkeit
Ansteuerung
– Reader – externer Pulsgeber
Eingänge
- 1 x Optokoppler (externer Trigger)
Signalgeber
* Maximales Anzugsdehmoment: 0,45Nm
SMA Buchse (50 ) * SMA Buchse (50 ) *
elektronische Schalter (verschleißfrei) < 1 ms
Kommunikation über RF Eingang 1 externer Trigger
5 – 24 V DC/ 20 mA (Pulsbreite 1ms – 100ms)
1 x LED pro Kanal
3 x LED ( Run / HF / Kommunikation )
FEIG ELECTRONIC GmbH Seite 18 von 37 M30201-1de-ID-B.doc
OBID i-scan
Umgebungsbedingungen
Temperaturbereich
– Betrieb – Lagerung
Montage ID ISC.ANT.MUX
-25°C bis +65°C
-40°C bis +80°C
D E U T S C H
EMV
Vibration
Schock
EN61000-6-3 EN61000-6-2
EN60068-2-6 10 Hz bis 150 Hz : 0,075 mm / 1 g
EN60068-2-27 Beschleunigung : 30 g
FEIG ELECTRONIC GmbH Seite 19 von 37 M30201-1de-ID-B.doc
OBID i-scan
D E U T S C H
Montage ID ISC.ANT.MUX
FEIG ELECTRONIC GmbH Seite 20 von 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
Note
Copyright 2003 by
FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
E N G L I S H
The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
OBID i-scan
is registered trademark of FEIG ELECTRONIC GmbH.
FEIG ELECTRONIC GmbH Page 21 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
Content
6. Safety Instructions / Warning - Read before Start-Up ! 23
7. Performance Features of the ID ISC.ANT.MUX 8x Antenna Multiplexer 24
7.1. Performance Features.................................................................................................... 24
7.2. Scope of Delivery ........................................................................................................... 24
8. Wiring and Installation 25
8.1. Installing the Enclosure ................................................................................................. 25
E N G L I S H
8.2. Terminals and Jacks ...................................................................................................... 26
8.3. X1: Supply Voltage......................................................................................................... 26
8.4. X2: Input (Opto-Coupler)................................................................................................ 27
8.5. IN1-2: Reader Connection.............................................................................................. 28
8.6. OUT1-8: Antenna Connection........................................................................................ 28
9. Operating and Display Elements 29
9.1. LEDs................................................................................................................................ 29
9.2. DIP Switch S1 ................................................................................................................. 30
9.2.1. Setting the Modes..................................................................................................... 30
9.2.2. Address Setting in HF Communication Control Mode................................................ 30
9.2.3. Setting Single or Dual Mode in External Trigger Mode.............................................. 31
9.2.4. Setting Number of Outputs in External Trigger Mode................................................ 31
9.3. Jumpers JP1- 8............................................................................................................... 32
9.4. Jumpers JP11 - JP18...................................................................................................... 33
9.5. Jumpers JP19 and JP20................................................................................................ 33
10. Start-Up 34
10.1. HF Communication Control Mode............................................................................... 34
10.2. External Trigger Mode.................................................................................................. 35
APPENDIX A: Technical Data 36
FEIG ELECTRONIC GmbH Page 22 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
6. Safety Instructions / Warning - Read before Start-Up !
The device may only be used for the intended purpose designed by for the manufacturer.
The operation manual should be conveniently kept available at all times for each user.
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device.
Repairs may only be executed by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
E N G L I S H
Before opening the device, the power supply must always be disconnected . Make sure that the device is without voltage by measuring with a test instrument. CAUTION! The fading illumination of an operational control (LED) should not be used as a sufficient indicator for an interrupted power supply or the device being without voltage!
Use of t the device and its installation must be in accordance with national legal requirements and local electrical codes .
FEIG ELECTRONIC GmbH Page 23 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
7. Performance Features of the ID ISC.ANT.MUX 8x Antenna Multiplexer
7.1. Performance Features
The ID ISC.ANT.MUX 8x antenna multiplexer is designed for switching RFID antennas having an operating frequency of 13.56 MHz. An ID ISC.ANT.MUX allows multiple individual antennas (base antennas) or gate antennas (base + complementary antennas) to be operated with just a single reader. All eight outputs on the antenna multiplexer can be assigned to each of the two inputs by means of jumper settings.
It is possible to cascade several ID ISC.ANT.MUX to increase the number of possible antenna
E N G L I S H
connections. Here the antenna multiplexers are addressed using DIP switch settings.
7.2. Scope of Delivery
The following components are included:
y 8x antenna multiplexer ID ISC.ANT.MUX
y 8 x protection caps for M16 cable fitting
y Installation Guide
FEIG ELECTRONIC GmbH Page 24 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
8. Wiring and Installation
8.1. Installing the Enclosure
The antenna multiplexer is designed for a wall mounted installation,and is suitable for outdoor. For wall attachment, break-outs are located in the corners of the enclosure (see Figure 1).
180
165
5
ø
x
4
E N G L I S H
Figure 1: Dimensions and mounting holes
The cable fittings are M16 x 1.5 for a clamping range of 4.5mm to 10mm.
95
110
FEIG ELECTRONIC GmbH Page 25 of 37 M30201-1de-ID-B.doc
OBID i-scan
1
2
Installation ID ISC.ANT.MUX
8.2. Terminals and Jacks
Figure 2 shows the terminals, jacks, DIP switches, jumpers and LED indicators.
OUT 1OUT 2OUT 3OUT 4
X2
E N G L I S H
X1
JP20
JP19
JP14 JP13 JP12 JP11
12345678
S1
LED1 LED2 LED3
X3
LEDout5 LEDout6 LEDout7 LEDout8
JP15 JP16 JP17 JP18
ON
OFF
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
LEDout1LEDout2LEDout3LEDout4
OUT 8OUT 7OUT 6OUT 5
Figure 2: Terminals, jacks and operating elements
IN
IN
8.3. X1: Supply Voltage
The supply voltage is connected to X1. Configure the polarity as shown in Figure 3. The antenna multiplexer operates with a DC voltage of 12V to 24V.
X1
12-24V DC
GND
Figure 3: Supply voltage connection
FEIG ELECTRONIC GmbH Page 26 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
8.4. X2: Input (Opto-Coupler)
The digital input on terminal X2 is used to trigger the multiplexer in the External-Trigger mode. The opto-coupler input is galvanically isolated from the antenna multiplexer and must therefore be externally supplied with DC voltage. The input LED on the opto-coupler is internally connected to a series resistor whose value is adjustable using jumpers JP11 and JP12 (s. Figure 4). The input­current should be between 10mA and 20mA. Set the jumpers according to Table 1 depending on the input voltage.
Table 1: Jumper settings for opto-coupler input
ext. voltage U
5V – 8V
8V – 12V
12V – 24V
ext
R
int
350
500
1,2 k
X2
JP20
JP19
JP19 JP20
In In
In Out
Out In
1,2 k
500
Figure 4: Input
The trigger signal on input X2 must lie within the limits shown in Figure 5. With higher frequencies it is recommended that the trigger signal and the transponder protocols be synchronized to prevent the connection between the reader and data carrier from being interrupted while a transponder is being read.
E N G L I S H
t
p
U
U
p
t
b
t
: 1 – 100ms
b
: > ( tb + 1ms )
t
p
: 5 – 24V
U
p
DC
t
Figure 5: Pulse for external trigger
FEIG ELECTRONIC GmbH Page 27 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
8.5. IN1-2: Reader Connection
The connection to a reader is made using coaxial cable to the SMA jacks IN1 and/or IN2. The maximum tightening torque of the SMA jacks is 0.45 Nm. The coax cables to the reader terminal should be routed through the sidewise cable fittings (see Figure 6).
E N G L I S H
Figure 6: Reader connection
Note:
For optimum read distance, the coax cable should be either less than 50cm or 7.20m in length.
8.6. OUT1-8: Antenna Connection
The antennas are connected using coaxial cable to the SMA jacks OUT1-8. The maximum tightening torque of the SMA jacks is 0.45 Nm. The connections to the SMA jacks OUT1-4 are made through the upper cable fittings, and the connections to OUT5-8 through the lower cable fittings (see Figure 7).
Figure 7: Antenna connections
FEIG ELECTRONIC GmbH Page 28 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
9. Operating and Display Elements
9.1. LEDs
The LEDs, located on the SMA jacks OUT1-8 (LEDout1-8), indicate whether the corresponding channel is switched or open. When a channel is switched, the corresponding LED will be on.
Table 2 shows the functions of LEDs LED1-3:
Table 2: LED1-3 function
Abbreviation Color Description
LED1 red Diagnostic 1: „Communication-LED“
HF-Communication Control Mode:
- Flashes on when the multiplexer has received a signal from the reader through SMA jack IN1.
- Comes on when multiplexer has detected an error at an output.
External Trigger Mode:
- Flashes on when the multiplexer has received a valid pulse through X2.
LED2 green Diagnostic 2: „HF-LED“
Comes on when an HF-signal is present on SMA jack IN1.
E N G L I S H
LED3 green „RUN-LED“:
Flashes (approx. 1Hz) when the internal software is running properly.
FEIG ELECTRONIC GmbH Page 29 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
9.2. DIP Switch S1
DIP switch S1 can be used to set the various multiplexer modes and addresses. After changing the DIP switch setting, you must perform a Power-Up Reset by briefly interrupting the supply voltage.
9.2.1. Setting the Modes
The modes are set using DIP switches 1 and 1. Table 3 shows a summary of the settings.
Table 3: Setting modes
E N G L I S H

DIP switch S1 Address

12345678
-- Reserved
-ON External Trigger Mode
4
ON - HF Communication Control Mode
ON ON Reserved
9.2.2. Address Setting in HF Communication Control Mode
The DIP switches can be used to set addresses for HF Communication Control Mode. DIP switches 3 and 4 are used for setting the corresponding level the levels.
Table 4: Address setting in HF Communication Control Mode
DIP switch S1 Address / Level
12345678
6
. Table 4 summarizes the settings for
5
ON --- not used
ON - -ON Level 1
ON -ON- Level 2
ON -ONON Level 3
4
see 10.2. External Trigger Mode
5
see 10.1. HF Communication Control Mode
6
Reference Manual H30701-#e-ID-B.doc
FEIG ELECTRONIC GmbH Page 30 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
9.2.3. Setting Single or Dual Mode in External Trigger Mode
In the external trigger mode the multiplexer can be used in single or dual mode. In single mode you can only switch on one output. In dual mode you can switch on two outputs, one for IN1 and one for IN2.
The dual mode is activated by turning on DIP switches 3 and 4. Otherwise the single mode is acti­vated (see Table 5).
9.2.4. Setting Number of Outputs in External Trigger Mode
DIP switches 5-8 are used to set the number of outputs used in Single or Dual Mode:
Table 5: Setting number of outputs in Single and Dual Mode
DIP switch S1 Channels
12345678
Single-Mode
E N G L I S H
- ON-----ONChannel 1
- ON - - - - ON - Channel 1-2
- ON - - - - ON ON Channel 1-3
- ON - - - ON - - Channel 1-4
- ON - - - ON - ON Channel 1-5
- ON - - - ON ON - Channel 1-6
- ON - - - ON ON ON Channel 1-7
- ON - - ON - - - Channel 1-8 Dual-Mode
- ON ON ON - - - ON Channel 1+8
- ON ON ON - - ON - Channel 1+8, 2+7
- ON ON ON - - ON ON Channel 1+8, 2+7, 3+6
- ON ON ON - ON - - Channel 1+8, 2+7, 3+6, 4+5
FEIG ELECTRONIC GmbH Page 31 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
9.3. Jumpers JP1- 8
Jumpers 1-8 can be used to assign the corresponding outputs OUT1-8 to the inputs IN1 and IN2 (see Figure 8).
OUTx
1
JPx
IN1
IN2
Figure 8: Assigning of output OUTx
The jumper position has no meaning for outputs which are not used. Table 6 shows two examples:
E N G L I S H
Table 6: Examples for jumper settings JP1-8
Jumper setting Assignment
Jumpers JP1-8 are all at position 2-3.
All outputs (OUT1-8) are then assigned to input IN1.
Jumpers JP1-4 are at position 2-3, jumpers JP5-8 at position 1-2.
This assigns outputs OUT1-4 to input IN1 and outputs OUT4-8 to input IN2.
JP1, JP3, JP4 and JP6 are at position 2-3; JP2, JP5 and JP7 at position 1-2
This assigns outputs OUT1, 3, 4, 6 to input IN1 and outputs OUT2, 5, 7 to input IN2. Output OUT8 is not assigned to an input.
FEIG ELECTRONIC GmbH Page 32 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
9.4. Jumpers JP11 - JP18
With the Jumpers JP11 – JP18 a DC-Offset of + 7V is switched on to the according output OUT1 – OUT8. The maximum DC-current for one output is 100mA.
9.5. Jumpers JP19 and JP20
Jumpers JP19 and JP20 are used to set the input resistance for the opto-coupler input on X2. Table 1 (Section 8.4. X2: Input (Opto-Coupler)) lists the possible settings.
E N G L I S H
FEIG ELECTRONIC GmbH Page 33 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
10. Start-Up
10.1. HF Communication Control Mode
In HF Communication Control Mode the multiplexer is controlled by protocols from the reader. No additional cable between the reader and multiplexer is necessary. The protocols are described in the system manual for the H30701-#e-ID-B.
The communication between the reader and multiplexer allows specific switching to a particular outputs.
Figure 9 shows a simple application example with a multiplexer and four antennas. Use the following DIP switch setting (see 9.2. DIP Switch S1):
E N G L I S H
Table 7: DIP switch setting
1 2 3 4 5 6 7 8
ON--ON----
12-24VDC
Antennas
OUT1-4
MUX
IN1
X1
50cm
Reader
Figure 9: Application example with four antennas in HF Communication Control Mode
FEIG ELECTRONIC GmbH Page 34 of 37 M30201-1de-ID-B.doc
OBID i-scan
Installation ID ISC.ANT.MUX
10.2. External Trigger Mode
In External Trigger Mode the multiplexer is controlled through input X2 (see 3.4. X2: Eingang (Optokoppler)). The set outputs are switched on one after the other in numerical order.
Jumper settings for jumpers JP19 and JP20 as well the pulse width of the external trigger signal is described in section 3.4. X2: Eingang (Optokoppler).
Figure 10 shows a simple application example with one multiplexer and four antennas. Use the following DIP switch settings (see 9.2. DIP Switch S1):
Table 8: DIP switch setting
1 2 3 4 5 6 7 8
-ON---ON--
E N G L I S H
12-24VDC
Antennas
OUT1-4
MUX
IN1
X2 X1
50cm
Reader
Figure 10: Application example with four antennas in External Trigger Mode
FEIG ELECTRONIC GmbH Page 35 of 37 M30201-1de-ID-B.doc
OBID i-scan

APPENDIX A: Technical Data

Mechanical Data
Installation ID ISC.ANT.MUX
Dimensions ( W x H x D )
Weight
Enclosure rating
Cable fittings
E N G L I S H
Electrical Data
Supply voltage
Power consumption
Operating frequency
Attenuation per channel
max. Permissible switching power
182mm x 110mm x 90mm
approx. 550 g
IP65
12 x cable fitting M16 x 1.5
12 - 24 V DC
max. 4 W
13.56 MHz
max. 0.5dB
10 W
RF connections
- 2 x input
- 8 x output
RF switches
– Switching speed
Triggering
– Reader – external pulse generator
Inputs
- 1 x Opto-coupler (external trigger)
Signal indicator
* Maximum tightening torque: 0.45Nm
SMA jack (50) * SMA jack (50) *
Electronic switches (non-wearing) < 1ms
Communication via RF input 1 External trigger
5 - 24 V DC/ 20 mA (pulse width 1ms – 100ms)
1 x LED per channel
3 x LED ( Run / HF / Communication )
FEIG ELECTRONIC GmbH Page 36 of 37 M30201-1de-ID-B.doc
OBID i-scan
Ambient Conditions
Temperature range
– Operating – Storage
Installation ID ISC.ANT.MUX
-25°C to +65°C
-40°C to +80°C
EMC
Vibration
Shock
EN61000-6-3 EN61000-6-2
EN60068-2-6 10 Hz to 150 Hz :0.075 mm / 1 g
EN60068-2-27 Acceleration : 30 g
E N G L I S H
FEIG ELECTRONIC GmbH Page 37 of 37 M30201-1de-ID-B.doc
INSTALLATION
final public (B) 2017-10-24 M50101-2de-ID-B.doc
ID ISC.ANT800/600-DA
Antenna with dynamic Tuner and Reader ID ISC.LR2500
(deutsch / english)
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 2 von 42
M50101-2de-ID-B.doc
D E U T S C H
E N G L I S H
deutsche Version ab Seite 3
english version from page 24
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 3 von 42
M50101-2de-ID-B.doc
D E U T S C H
Hinweis
Copyright 2005-2012 by
FEIG ELECTRONIC GmbH Lange Straße 4 D-35781 Weilburg Tel.: +49 6471 3109-0
http://www.feig.de
Alle früheren Ausgaben verlieren mit dieser Ausgabe ihre Gültigkeit. Die Angaben in diesem Dokument können ohne vorherige Ankündigung geändert werden.
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten.
Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung für die Richtigkeit und Vollständigkeit der An­gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht für Folgeschäden auf Grund fehlerhafter oder unvollständiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bemü­hungen nie vollständig vermeiden lassen, sind wir für Hinweise jederzeit dankbar.
Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingun­gen aus. FEIG ELECTRONIC GmbH übernimmt keine Gewähr für die einwandfreie Funktion in systemfrem­den Umgebungen.
FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthal­tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte.
OBID® und OBID i-scan® ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH
Microsoft® und Windows® sind eingetragene Warenzeichen der Microsoft Corporation
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 4 von 42
M50101-2de-ID-B.doc
D E U T S C H
Inhalt
1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen 5
2 Leistungsmerkmale der Antenne ID ISC.ANT800/600-DA 6
3 Montage und Anschluss 7
3.1 Montage des Gehäuses .............................................................................................. 7
3.2 Hinweise zur Kabelführung der Antennenzuleitung ................................................. 8
4 Inbetriebnahme 9
4.1 Benötigte Komponenten ............................................................................................ 9
4.2 Aufbau der Antenne.................................................................................................. 10
4.3 Einstellung des Antennentuners ............................................................................. 10
4.4 Abgleich der Antenne ............................................................................................... 11
5 Geräteanordnungen mit der Antenne ID ISC.ANT800/600-DA 14
5.1 Standard-Applikationen ........................................................................................... 14
5.2 Funk-Regularien im EU-Raum und den USA .......................................................... 15
5.2.1 Zugelassenen Readereinstellung ................................................................................ 16
5.2.2 Spezieller Antennenaufbau ......................................................................................... 17
Technische Daten 19
5.3 Zulassung .................................................................................................................. 21
5.3.1 Europa (CE) ................................ ................................................................ ................ 21
5.3.2 USA (FCC) und Kanada (IC)....................................................................................... 22
6 Lieferumfang: 22
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 5 von 42
M50101-2de-ID-B.doc
D E U T S C H
1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
Das Gerät darf nur für den vom Hersteller vorgesehenen Zweck verwendet werden. Die Bedienungsanleitung ist zugriffsfähig aufzubewahren und jedem Benutzer auszuhändigen. Unzulässige Veränderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen,
die nicht vom Hersteller des Gerätes verkauft oder empfohlen werden, können Brände, elektri­sche Schläge und Verletzungen verursachen. Solche Maßnahmen führen daher zu einem Ausschluss der Haftung, und der Hersteller übernimmt keine Gewährleistung.
Für das Gerät gelten die Gewährleistungsbestimmungen des Herstellers in der zum Zeitpunkt
des Kaufs gültigen Fassung. Für eine ungeeignete, falsche manuelle oder automatische Ein­stellung von Parametern für ein Gerät bzw. ungeeignete Verwendung eines Gerätes wird kei­ne Haftung übernommen.
Reparaturen dürfen nur vom Hersteller durchgeführt werden. Anschluss-, Inbetriebnahme-, Wartungs- und sonstige Arbeiten am Gerät dürfen nur von
Elektrofachkräften mit einschlägiger Ausbildung erfolgen.
Vor dem Öffnen des Gerätes ist stets die Versorgungsspannung abzuschalten und durch
Nachmessen sicherzustellen, dass das Gerät spannungslos ist. Das Verlöschen einer Be­triebsanzeige ist kein Indikator dafür, dass das Gerät vom Netz getrennt und spannungslos ist.
Alle Arbeiten am Gerät und dessen Aufstellung müssen in Übereinstimmung mit den nationa-
len elektrischen Bestimmungen und den örtlichen Vorschriften durchgeführt werden.
Beim Arbeiten an den Geräten müssen die jeweils gültigen Sicherheitsvorschriften beachtet
werden.
Beim Arbeiten am geöffneten Gerät ist zu beachten, dass Spannungen bis zu 1000V an den
Bauteilen anliegen können.
Beim Arbeiten am geöffneten Gerät ist zu beachten, dass einige Bauteile sich stark erwärmen
können. Verbrennungsgefahr !
Besonderer Hinweis für Träger von Herzschrittmachern: Obwohl dieses Gerät die zulässigen Grenzwerte für elektromagnetische Felder nicht überschreitet,
sollten Sie einen Mindestabstand von 25 cm zwischen dem Gerät und Ihrem Herzschrittmacher einhalten und sich nicht für längere Zeit in unmittelbarer Nähe des Geräts bzw. der Antenne auf­halten.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 6 von 42
M50101-2de-ID-B.doc
D E U T S C H
2 Leistungsmerkmale der Antenne ID ISC.ANT800/600-DA
Die Antenne ID ISC.ANT800/600-DA ist eine Single Loop Antenne mit Abgleichelektronik und wur­de als eine Sende- und Empfangsantenne für den Reader ID ISC.LR2500 optimiert. Bei einer ein­gestellten Sendeleistung von 4 W ist eine Lesereichweite von bis zu 100 cm möglich. Ebenfalls ist ein Betrieb an anderen Readern mit einer Sendefrequenz von 13,56 MHz und der Ausgangsimpe­danz von 50 möglich.
Die Antenne besteht aus dem elektrischen Antennenleiter, Gehäuse und der Abgleichelektronik ID ISC.DAT (Tuner).
Die Antenne wurde im Werk an einer Holzplatte auf die Impedanz von 50 abgestimmt. Nach der Montage in anderen Umgebungsbedingungen kann die Antenne mit Hilfe der entsprechenden Be­fehle (s. Manual Communication FU, H30701-xe-ID-B) abgestimmt werden.
Die Antenne kann sowohl für die Güter- als auch in der Personenerkennung verwendet werden. Sie ist für die Montage im Innen- wie auch den Außenbereich geeignet
Die Vorzugsrichtung eines Smart Label ist parallel zur Antennenfläche. Die maximale Reichweite wird über der Mitte der Antennenfläche erreicht.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 7 von 42
M50101-2de-ID-B.doc
D E U T S C H
3 Montage und Anschluss
3.1 Montage des Gehäuses
Die Antenne ID ISC.ANT800/600-DA ist für die Montage an Halterungen aus nicht leitenden Mate­rialien (z.B. Kunststoff oder Holz) sowohl für den Innen- wie auch den Außenbereich konzipiert. Zur Befestigung der Antenne befinden sich im Innenbereich der Antenne 6 Bohrungen (d=5,4 mm, s. Bild 1). Zur Montage empfehlen wir eine 5 mm Holzschraube (DIN 96) oder eine Maschinen­schraube (DIN 7985) mit einem Kopfdurchmesser von mindestens 10 mm bis maximal 12 mm. Das maximale Anzugsmoment für freidrehende Schrauben beträgt 2,0 Nm.
Reichen die vorhandenen Bohrungen nicht aus, können innerhalb des schraffierten Bereichs, wei­tere Löcher (d=5,4 mm) gebohrt werden.
Nur wenn Veränderungen der Voreinstellung am Antennen Tuner ID ISC.DAT notwendig sind (s. 4.3 Einstellung des Antennentuners), muss der Gehäusedeckel entfernt werden. Das Anzugs­moment der Deckelschrauben beim Verschließen der Antenne beträgt 0,25 Nm.
Bild 1: Montagezeichnung ID ISC.ANT800/600-DA (alle Maße in mm)
Hinweis: Die Antenne muss einen Mindestabstand von 10 cm von Metallteilen haben! Schon
ab 50 cm Abstand zu Metallteilen muss mit Einbußen in der Lesereichweite ge­rechnet werden.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 8 von 42
M50101-2de-ID-B.doc
D E U T S C H
3.2 Hinweise zur Kabelführung der Antennenzuleitung
Bei der Kabelführung bzw. beim Aufbau von Einzelantennen oder Antennen Gates ist auf folgen­des zu achten:
Das Antennenkabel ist immer vor dem Abgleichen fest zu verlegen. Bis zu einem Abstand von 50 cm sollte das Antennenkabel immer senkrecht von der Antenne
weg geführt werden.
Muss das Antennenkabel näher an der Antenne entlang verlegt werden, so sind mindestens
20 cm Abstand einzuhalten.
Ein Verlegen des Antennenkabel durch die Antenne ist immer ungünstig. Um optimale Lesereichweiten zu erzielen sollte das Antennenanschlusskabel nicht verkürzt
oder verlängert werden. Ist eine Verlängerung zwingend erforderlich, so kann dies mit einem 50 Kabel in der Länge /2 (ID ISC.ANT.EC Extension Cable, halbe Wellenlänge bei 13,56 MHz, RG58=7,20 m) durchgeführt werden. Dabei ist mit geringen Empfindlichkeitsverlusten zu rechnen.
Das Antennenkabel muss einen Abstand von wenigstens 30 cm zu parallel geführten stromfüh-
renden Leitungen haben.
Um mögliche Störungen zu unterdrücken, sollten in alle Anschlusskabel der Antennen und des Power Splitters je ein EMV-Ringkern da=28 mm eingebaut werden. Dafür ist das Koaxialkabel mindestens vier mal, eng anliegend durch den EMV-Ringkern zu schleifen. Der Abstand zwischen Readeranschluss und Ringkern sollte dabei maximal 10 cm betragen.
Bild 2: Montage EMV-Ringkern auf Anschlusskabel
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 9 von 42
M50101-2de-ID-B.doc
D E U T S C H
4 Inbetriebnahme
Die Inbetriebnahme der Antenne ID ISC.ANT800/600-DA wird an Hand einer einfachen Konfigura­tion aus einem Reader und einer Antenne erläutert. Zum Abgleichen der Antenne wird eine DC­Spannungsversorgung für den Antennentuner benötigt. Die Spannungsversorgung als auch die HF Signale werden über das Koaxialkabel eingespeist. Der im Beispiel verwendete Reader ID ISC.LR2500 verfügt über die Möglichkeit, eine Antenne mit DC - Spannung zu versorgen. Weitere Möglichkeiten zur Spannungsversorgung eines Antennentuners ID ISC.DAT können der entsprechenden Montageanleitung (M40401-xde-ID-B) entnommen werden.
4.1 Benötigte Komponenten
Folgende Komponenten werden für den oben beschriebenen Aufbau benötigt:
- Reader ID ISC.LR2500-A Long Range Reader
- Antenne ID ISC.ANT800/600-DA Base Antenna
Die Kabel an der Antenne ID ISC.ANT800/600-DA ist ca. 3,60m lang. Um eine optimale Lesereichweite, bei Aufbauten mit einer Antenne und einem Leser ID ISC.LR2500, zu erzielen sollte das Kabel gegen ein 1,35m Kabel ausgetauscht werden. In diesem Fall wird zusätzlich benötigt:
- ID ISC. ANTC135 Antenna cable 1,35m
Bei größeren Abständen zwischen Reader und Antennen kann mit der Verlängerung ID ISC.ANT.EC das Antennenkabel um 7,20m Kabel verlängert werden. Dies führt allerdings zu geringen Leistungseinbusen.
Zur Kabelverlängerung wird benötigt:
- ID ISC.ANT.EC Extension Cable
Zur Inbetriebnahme wird die Servicesoftware
- ISOStart ab Version 9.01
auf einem Personal Computer mit Microsoft® Windows® Betriebssystem benötigt. Die Servicesoftware ist auf dem Download Bereich der Firma FEIG ELECTRONIC GmbH unter
www.feig.de zu finden.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 10 von 42
M50101-2de-ID-B.doc
D E U T S C H
Funktion
Jumper
Position
1 Gütewiderstand
JP1
geschlossen
2 Gütewiderstand
JP2
offen
Antennenschalter
JP3
geschlossen
X6
ANT1
X3
1,35m
Abgleichplatine der
Antenne ID ISC.ANT800/600-DA
Ringkern
Long Range Reader
ID ISC.LR2500
4.2 Aufbau der Antenne
Bild 3 aufzubauen.
Die einzelnen Komponenten sind wie in
Bild 3 Aufbau der Konfiguration
4.3 Einstellung des Antennentuners
Die Antennen ID ISC.ANT800/600-DA werden ab Werk mit folgender Einstellung der Jumper aus­geliefert. Die Einstellung sind für die Antenne zu überprüfen.
Tabelle 1: Jumperstellung Abgleichplatinen
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 11 von 42
M50101-2de-ID-B.doc
D E U T S C H
Step
Vorgang
Hinweis
1
ISOStart Software starten
2
„Detect“ ausführen...
Hinweis: Siehe hierzu auch die Montageanleitung des dynamischen Antennentuners ID ISC.DAT (M40401-xde-ID-B).
4.4 Abgleich der Antenne
Zum Abgleichen der Antenne ist die Software ISOStart zu öffnen und zunächst die aktuelle Konfi­guration des Reader auszulesen:
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 12 von 42
M50101-2de-ID-B.doc
D E U T S C H
Step
Vorgang
Hinweis
3
„Run without change“
anwählen
Dies bei jedem erneuten Öffnen des ISO-Start auswählen , da ansonsten die ursprüngliche Konfiguration überschrieben wird.
4
Options => Program auswählen
5
Expert Mode auswählen und mit OK bestätigen.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 13 von 42
M50101-2de-ID-B.doc
D E U T S C H
Step
Vorgang
Hinweis
6
Logical View anwählen.
Step
Vorgang
Hinweis
7
Menü „Configuration“ aus­wählen
8
Air Interface:
“Output - Power” = 4W
„Mulitplexer enable“
abwählen „Transponder-Driver“
wählen (hier ISO 15693) „EnableDCPower
anwählen
9
mit „Apply“ programmieren
Die gewünschte Sendeleistung ist einzustellen und die Antenne abzugleichen.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 14 von 42
M50101-2de-ID-B.doc
D E U T S C H
Step
Vorgang
Hinweis
10
Transponder:
Konfigurieren Sie die Parameter wie folgt:
„Driver“ – hier ISO 15693 „Anticollision“ – enable
„PersistenceResetTime“
20 x 5 ms „No of Timeslots“ – 1
timeslot „Data Coding“ – 1 of 4 „AFI“ – Disabled
11
mit „Apply“ programmieren
12
Operating Mode:
Vor dem Abgleichen der
Antenne ist der „Host
Mode“ zu aktivieren
13
mit „Apply“ programmieren
14
Menü „Commands“
auswählen
15
„Start Tuning“ auf Tuner­Address 1 durchführen.
Die Abgleichprozedur kann bis zu 30s andauern.
16
Abgleichergebnis mit „Get
Antenna Values“ kontrollie-
ren.
17
Wenn Tuning Status nicht „OK“ Schritt 15 & 16 wiederholen.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 15 von 42
M50101-2de-ID-B.doc
D E U T S C H
Application-Note:
Configuring and Tuning an
Antenna Gate from four or six
ID ISC.ANT800/600-DA Antennas
(N70301-xD-ID-B)
Application-Note:
Configuring and Tuning
an Antenna Gate from
from ID ISC.ANT800/600-DA Antennas
(N70302-xD-ID-B)
5 Geräteanordnungen mit der Antenne ID ISC.ANT800/600-DA
Abhängig von der Applikation und den national geltenden Funkvorschriften sind verschiedene An­tennenaufbauten möglich. Dabei können mehrere Antennen ID ISC.ANT800/600-DA zusammen mit einem oder mehreren Power Splittern ID ISC.ANT.PS-B und/oder mit einem Multiplexer ID ISC.ANT.MUX kombiniert werden.
5.1 Standard-Applikationen
Zu den Standard-Applikationen gehören neben der in Kap. 4 Inbetriebnahme beschriebenen Ein­zelantenne auch die Antennenaufbauten, bei denen mehrere Antennen als Gate kombiniert sind. Für die grundlegenden Kombinationen existieren Application-Notes, aus denen wieder weitere Antennenaufbauten abgeleitet werden können. Folgende Application-Notes erhältlich:
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 16 von 42
M50101-2de-ID-B.doc
D E U T S C H
5.2 Funk-Regularien im EU-Raum und den USA
Die Konfiguration der RFID Leser und die maximale Sendeleistung der Antennen werden im we­sentlichen durch die länderspezifischen Funk-Vorschriften beeinflusst. Für den gesamten EU gel­ten einheitliche Grenzwerte nach der R&TTE Richtlinie und EN 300 330. In Nord Amerika wird dies durch die FCC Part 15 (USA) bzw. RSS210 (Kanada) geregelt.
Die Antenne ID ISC.ANT800/600 mit dem Leser ID ISC.LRM2500-B entspricht, bei bestimmungs­gemäßer Verwendung den grundlegenden Anforderungen des Artikels 3 und den übrigen ein­schlägigen Bestimmungen der R&TTE Richtlinie 1999/5/EG vom März 1999. Daher ist der Betrieb in den 27 EU-Staaten und den EFTA Staaten (EU-Staaten und Schweiz, Norwegen und Island) mit einer maximalen Feldstärke von 42 dBµA/m in 10 m Entfernung möglich.
Eine Funkzulassung (bei einer maximalen Feldstärke von 84 dBµV/m in 30 m Entfernung) für die Antenne ID ISC.ANT800/600 mit dem Leser ID ISC.LRM2500-B nach FCC Part 15 für die USA und RSS 210 für Kanada wurde erteilt.
Weiterhin ist eine Funkzulassung nach der Norm EN 300 330 in allen 46 CEPT Staaten möglich. Die CEPT Staaten sind: Albania (ALB), Andorra (AND), Austria (AUT), Azerbaijan (AZE), Belarus (BLR), Belgium (BEL),
Bulgaria (BUL), Bosnia and Herzegovina (BIH), Croatia (HRV), Cyprus (CYP), Czech Republic (CZE), Denmark (DNK), Estonia (EST), Finland (FIN), France (F), Germany (D), Greece (GRC), Hungary (HNG), Iceland (ISL), Ireland (IRL), Italy (I), Latvia (LVA), Liechtenstein (LIE), Lithuania (LTU), Luxembourg (LUX), Malta (MLT), Former Yugoslav Republic of Macedonia (MKD), Moldova (MDA), Monaco (MCO), Netherlands (HOL), Norway (NOR), Poland (POL), Portugal (POR), Ro­mania (ROU), Russian Federation (RUS), San Marino (SMR), Slovak Republic (SVK), Slovenia (SVN), Spain (E), Sweden (S), Switzerland (SUI), Turkey (TUR), Ukraine (UKR), United Kingdom (G), Vatican City (CVA) and Yugoslavia.
Es gelten folgende Einschränkungen (Stand: August 2011):
1. Außerhalb der EFTA Staaten muss in jedem Fall eine Funkzulassung beantragt werden. Die vorhandenen Messprotokolle nach EN 300 330 sind in der Regel ausreichend.
Bei der Inbetriebnahme der Antennen ist vom Systemintegrator darauf zu achten, dass die vorge­schriebenen Montagehinweise beachtet, die notwendigen Reader Einstellungen durchgeführt und zulässigen Grenzwerte der nationalen Funk Vorschriften nicht überschritten werden.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 17 von 42
M50101-2de-ID-B.doc
D E U T S C H
Parameter
Europa
USA / Kanada
Allgemein
RF-Power – CFG 3
4 W
2 W
ISO15693 Label
RF Modulation – CFG 20
10 %
10%
Downlink RF Data coding – CFG 4 / ISO-MODE / FAST
Normal (1/256)
Normal (1/256) No of Timeslots - CFG 4
1 or 16 Timeslots
1 or 16 Timeslots
5.2.1 Zugelassenen Readereinstellung
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 18 von 42
M50101-2de-ID-B.doc
D E U T S C H
- Die beiden Antennen müssen in einer Ebene di­rekt nebeneinander montiert werden.
- Die beiden Tuner (Öffnungen) der Antennen müs­sen nach außen (rechts und links) montiert werden und in eine Richtung zeigen.
- Abstand der Antennen (Ecken) 1cm.
Readereinstellung
Maximale Sendeleistung 4W
Antennentuner
Jumperstellung am Antennentuner ID ISC.DAT
- JP1: offen
- JP2: offen
- JP3: geschlossen
Power-Splitter
mit 180° Phasendrehung
5.2.2 Spezieller Antennenaufbau
Neben der Möglichkeit des Abschirmens von Antennen zum Einhalten der Regularien kann durch spezielle Antennenaufbauten eine Kompensation des magnetischen Feldes durch entgegenge­setzte Feldrichtungen erreicht werden. Dies wurde von FEIG ELECTRONIC GmbH für verschiede­ne Antennenaufbauten getestet und in einem Messlabor überprüft.
Voraussetzung dafür ist, dass die Antennen exakt wie beschrieben aufgebaut werden. Die Anten­nen müssen dabei mit einem Power Splitter ID ISC.ANT.PS verbunden werden. Um sicher zustel­len, dass der komplette Aufbau die nationalen Funk und EMV Grenzwerte einhält, muss dies vom Systemintegrator überprüft werden.
Der Antennenaufbau ist wie folgt durchzuführen:
Tabelle 2: Aufbau mit zwei Antennen ID ISC.ANT800/600-DA
Hinweise: Abgleichen dieser Antennenkonfiguration gemäß Application-Note:
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 19 von 42
M50101-2de-ID-B.doc
D E U T S C H
Configuring and Tuning an Antenna Gate from two ID ISC.ANT800/600-DA An­tennas (N50101-xe-ID-B).
Um die EMV Vorschriften in der USA nach FCC Part 15 einzuhalten, müssen in die Anschlusska­bel der Antennen ID ISC.ANT800/600-DA zwei Ringkerne wie in Bild 4 skizziert eingebaut werden.
Der dem Reader beigelegte EMV-Ringkern  28 mm x 20 mm ist am Anfang des Kabels einzu- bauen. Dafür ist die Antennenzuleitung mindestens vier mal, eng anliegend durch den Ringkern zu schleifen. Der Abstand zwischen Readeranschluss und Ringkern sollte dabei maximal 10 cm be­tragen.
Der EMV-Ringkern 41 mm x 15 mm ist genau in der Mitte des Antennenkabels zu montieren. Dafür ist das Koaxialkabel mindestens zehn mal, eng anliegend durch den Ringkern zu schleifen. Dieser Ringkerne sind dem Reader beigelegt.
Bild 4: Montage zweier Ringkerne auf Koaxialkabel
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 20 von 42
M50101-2de-ID-B.doc
D E U T S C H
Mechanische Daten
Gehäuse
Kunststoff ABS
Abmessungen ( B x H x T )
852 x 620 x 40 mm 1 mm
Gewicht
ca. 2,5 kg
Schutzart
IP 65
Farbe
Schwarz
Elektrische Daten
Maximale Sendeleistung
8 W
Zulässige Sendeleistung
EU-Raum (EN 300 330) USA (FCC Part 15)
- Kanada (RSS-210)
4,0 W 2,0 W 2,0 W
Betriebsfrequenz
13,56 MHz
Reichweite
Maximal 100 cm*
Antennenanschluss
1 x SMA Stecker (50 )
Antennenanschlusskabel
RG58, 50 , ca. 3,60 m lang
Umgebungsbedingungen
Temperaturbereich
Betrieb Lagerung
25°C bis +55°C 25°C bis +60°C
Vibration
EN60068-2-6 10 Hz bis 150 Hz : 0,075 mm / 1 g
Schock
EN60068-2-27 Beschleunigung : 30 g
Technische Daten
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 21 von 42
M50101-2de-ID-B.doc
D E U T S C H
Angewendete Normen
EMV
EN 300 683
Sicherheit
Europa USA
EN 60950 UL 60950 (Auf Anfrage)
*Label 46 x 75 mm2, über der Antennen Mitte, Empfindlichkeit / Minimale Feldstärke H rms, parallele Ausrichtung des Labels zur Antenne. Sendeleistung 4 W.
=60 mA/m
min
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 22 von 42
M50101-2de-ID-B.doc
D E U T S C H
5.3 Zulassung
5.3.1 Europa (CE)
Die Funkanlage entspricht, bei bestimmungsgemäßer Verwendung den grundlegenden Anforde­rungen des Artikels 3 und den übrigen einschlägigen Bestimmungen der R&TTE Richtlinie 1999/5/EG vom März 1999.
Equipment Classification gemäß ETSI EN 300 330 und ETSI EN 301 489: Class 2
Die technischen Daten des Readers ID ISC.LRM2500 finden Sie in der Montageanleitung.
OBID i-scan®
Montage
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 23 von 42
M50101-2de-ID-B.doc
D E U T S C H
Produkt Name:
ID ISC.ANT800/600-DA
Antennen Name:
ID ISC.ANT800/600-DA
Reader Name:
ID ISC.LRM2500
FCC ID:
IC:
PJMLRM2500
6633A-LRM2500
Notice for USA and
Canada
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under
Federal communications Commission Rules permitting the operation of this device.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Le présent appareil est conforme aux CNR d'Industrie Canada appli­cables aux appareils radio exempts de licence. L'exploitation est auto­risée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonc­tionnement.
5.3.2 USA (FCC) und Kanada (IC)
Die technischen Daten des Readers ID ISC.LRM2500 finden Sie in der Montageanleitung.
6 Lieferumfang:
Folgende Komponenten sind im Lieferumfang enthalten:
- Antenne ID ISC.ANT800/600-DA
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 24 of 42
M50101-2de-ID-B.doc
E N G L I S H
Note
Copyright 2005-2012 by
FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
Microsoft® und Windows® is a registered trademark of Microsoft Corporation
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 25 of 42
M50101-2de-ID-B.doc
E N G L I S H
Contents
7 Safety and warning notes – READ BEFORE STARTUP 26
8 Performance features of the ID ISC.ANT800/600-DA Antenna 27
9 Installation and wiring 28
9.1 Installing the housing ............................................................................................... 28
9.2 Notes on routing the antenna cable ........................................................................ 29
10 Startup 30
10.1 Required components .............................................................................................. 30
10.2 Constructing the antenna......................................................................................... 31
10.3 Setting the antenna tuner ......................................................................................... 31
10.4 Tuning the antenna ................................................................................................... 32
11 Device arrangements with the ID ISC.ANT800/600-DA antenna 35
11.1 Standard applications .............................................................................................. 35
11.2 RF regulations in EU countries and the USA .......................................................... 36
11.2.1 Permissible Reader settings ................................................................................... 37
11.2.2 Special antenna construction ................................................................................. 38
Technical Data 40
11.3 Approval .................................................................................................................... 41
11.3.1 Europe (CE) ........................................................................................................... 41
11.3.2 USA (FCC) and Canada (IC) .................................................................................. 42
12 Scope of delivery: 42
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 26 of 42
M50101-2de-ID-B.doc
E N G L I S H
7 Safety and warning notes – READ BEFORE STARTUP
The device may be used only for the purpose intended by the manufacturer. This manual should be kept in an accessible location and distributed to each user. Unauthorized modifications and the use of replacement parts and ancillary equipment not
purchased from or recommended by the manufacturer may result in fire, electric shock and injury. Such actions will void the warranty and the manufacturer will not be held liable for any consequences.
The device is covered under the warranty terms of the manufacturer in their iteration at the time
of purchase. No liability is assumed for unsuitable, incorrect manual or automatic setting of parameters for a device or for inappropriate use of a device.
Repairs are to be performed solely by the manufacturer. Wiring, startup, maintenance or other work on the device are to be performed only by electricial
technicians having the relevant training and education.
Before opening the device, always turn off power and use a meter to ensure that the device is
in fact not receiving power. The extinguishing of a power LED is not a reliable indicator that the device is separated from the mains and is safe to work on.
All work on the device including its installation must conform with national electrical regulations
and local code.
When working on the devices, always refer to the relevant safety regulations. When performing work on a device which has been opened, note that voltages of up to 1000V
may be present on the components.
When performing work on a device which has been opened, note that some components may
become extremely hot. Risk of burn injury !
Special note for persons wearing heart pacemakers: Although this device does not exceed the permissible limits for electromagnetic fields, you should
keep a minimum distance of 25 cm between the device and your pacemaker, and not remain in the direct vicinity of the device or antenna for longer periods of time.
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 27 of 42
M50101-2de-ID-B.doc
E N G L I S H
8 Performance features of the ID ISC.ANT800/600-DA Antenna
The ID ISC.ANT800/600-DA antenna is a single loop antenna with tuning circuitry and has been optimized as a sending and receiving antenna for the ID ISC.LR2500 Reader. With a set transmitting power of 4 W a read range of up to 100 cm is possible. Operation with other Readers having a transmitting frequency of 13.56 MHz and an output impedance of 50 is likewise possible.
The antenna consists of the electrical antenna conductor, housing and the tuning circuitry ID.ISC.DAT (Tuner).
The antenna was factory tuned on a wood base to an impedance of 50 . After installing in other ambient conditions, the antenna can be tuned using the corresponding commands (see Manual Communication FU, H30701-xe-ID-B).
The antenna can be used for detecting either goods or persons. It is suitable for indoor or outdoor installation.
The preferred orientation of a Smart Label is parallel to the antenna area. The maximum range is achieved over the center of the antenna area.
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 28 of 42
M50101-2de-ID-B.doc
E N G L I S H
9 Installation and wiring
9.1 Installing the housing
The ID ISC.ANT800/600-DA antenna is designed for installation on holders made of non­conducting materials (e.g. plastic or wood) either indoors or outdoors. 6 mounting holes are provided inside the antenna for attaching (d=5.4 mm, see Fig. 5). We recommend use of a 5 mm wood screw (DIN 96) or a machine screw (DIN 7985) having a head diameter of at least 10 mm up to a maximum of 12 mm. The maximum tightening torque for free-turning screws is 2.0 Nm.
If the existing holes are not sufficient, additional holes (d=5.4 mm) can be drilled inside the hatched area.
The housing cover only needs to be removed when making changes to the factory setting on the ID ISC.DAT Tuner (see 10.3 Setting the antenna tuner), the tightening torque for the cover screws when closing up the antenna is 0.2 Nm – 0.25 Nm.
Fig. 5: Installation drawing for ID ISC.ANT800/600-DA (all dimensions in mm)
Note: The antenna must be kept a minimum of 10 cm away from metal parts! Even at
distances of 50 cm or closer a sacrifice in reading range must be anticipated.
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 29 of 42
M50101-2de-ID-B.doc
E N G L I S H
9.2 Notes on routing the antenna cable
Note the following when routing the cable and constructing individual antennas or antenna gates:
The antenna cable must always be routed in place before tuning. Up to a distance of 50 cm the antenna cable should always be routed vertically away from the
antenna.
If the cable needs to be routed closer along the antenna, keep a distance of at least 20 cm. Routing the antenna cable through the antenna itself is always detrimental. To achieve optimum read ranges, the antenna cable should not be shortened or extended. If an
extension is absolutely necessary, this can be done using a 50 cable of length /2 (ID ISC.ANT.EC Extension Cable, half-wavelength at 13.56 MHz, RG58=7.20 m). A slight loss of sensitivity must then be taken into account.
The antenna cable must be kept a distance of at least 30 cm from parallel routed current-
carrying cables.
To suppress possible interference, an EMC ring core with an O.D. of 28 mm should be installed in all antenna cables and the power splitter. Wind the coax cable at least four times tightly through the EMC ring core as shown in the illustration. The distance between the Reader connection and the ring core should be a maximum of 10 cm.
Fig. 6: EMC ring core installed on an antenna cable
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 30 of 42
M50101-2de-ID-B.doc
E N G L I S H
10 Startup
The ID ISC.ANT800/600-DA is placed in service using a simple configuration consisting of a Reader and an antenna. To tune the antenna a DC voltage supply is needed for the antenna tuner. The supply voltage as well as the HF signals are carried on the coax cable. The ID ISC.LR2500 Reader used in the example is able to provide an antenna with DC voltage. Other ways of powering an ID ISC.DAT antenna tuner can be found in the corresponding installation guide (M40401-xde-ID-B).
10.1 Required components
The following components are needed for the configuration described above:
- Reader ID ISC.LR2500 Type -A or -B
- Antenna ID ISC.ANT800/600-DA
The cables on the ID ISC.ANT800/600-DA antenna are each approx. 3,60m long. To get the optimal performance at the setup with one antenna and one Reader ID ISC.LR2500 the
antenna cable should be changed to a 1,35m cable. So you need:
- ID ISC. ANTC135 Antenna cable 1,35m
For longer distances between Reader and antennas the ID ISC.ANT.EC extension can be used to extend the antenna cable by 7.20m. This will result in slight loss of sensitivity.
For extending the cable you will need:
- ID ISC.ANT.EC
For startup the service software
- ISOStart Version 9.01 or higher
on a personal computer running under Microsoft® Windows® is required. The service can be downloaded at the Download Area of the Homepage www.feig.de.
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 31 of 42
M50101-2de-ID-B.doc
E N G L I S H
Function
Jumper
Position
1 Q-resistance
JP1
closed
2 Q-resistance
JP2
open
Antenna switch
JP3
closed
X6
ANT1
X3
1,35m
Tunning board of the
antenna ID ISC.ANT800/600-DA
torrid
Long Range Reader
ID ISC.LR2500
10.2 Constructing the antenna
The individual components are constructed as shown in Fig. 7: Antenna configuration
Fig. 7: Antenna configuration
10.3 Setting the antenna tuner
The jumpers on the ID ISC.ANT800/600-DA antennas are factory set as shown below. The settings should be verified for each antenna.
Table 3: Jumper settings on the tuner boards
Note: See also the installation guide for the ID ISC.DAT (M40401-xde-ID-B)
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 32 of 42
M50101-2de-ID-B.doc
E N G L I S H
Step
Action
Note
1
Start ISO Start Software
2
Select „Detect“
3
Select „Run without change“ Note: This has to be done at each
start of ISO-Start program otherwise the configuration of the reader will be changed by the wizard.
4
Select „Options => Program“
10.4 Tuning the antenna
To tune the antenna, open the ISOStart software and first read out the current Reader configuration:
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 33 of 42
M50101-2de-ID-B.doc
E N G L I S H
Step
Action
Note
5
Select „Expert Mode“ and
confirm with OK.
6
Select “Logical View”
Step
Procedure
Note
7
Select „Configuration“
8
Air Interface:
“Output - Power” = 4W Deselect: „Mulitplexer
enable“ Select: „Transponder-
Driver“ (here ISO 15693) Select: „EnableDCPower“
Now set the desired RF power and tune the antenna.
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 34 of 42
M50101-2de-ID-B.doc
E N G L I S H
Step
Procedure
Note
9
Set by clicking on „Apply“.
10
Transponder:
Configure the parameter as following:
„Driver“ Select: ISO 15693 Enable: „Anticollision“ „PersistenceResetTime“
20 x 5 ms „No of Timeslots“ –
1 timeslot „Data Coding“ – 1 of 4 „AFI“ – Disabled
11
Set by clicking on „Apply“.
12
Operating Mode:
To tune, activate „ISO-Host Mode“
13
Set by clicking on „Apply“.
14
Select „Commands“ menu
15
Select „Start Tuning“ for
Tuner Address 1. The tuning procedure may
take up to 30s.
16
Check tuning results by
using „Get Antenna
Values“.
17
If Tuning Status is not „OK“ repeat Step 15 & 16.
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 35 of 42
M50101-2de-ID-B.doc
E N G L I S H
Application-Note:
Configuring and Tuning an
Antenna Gate from four or six
ID ISC.ANT800/600-DA Antennas
(N70301-xe-ID-B)
Application-Note:
Configuring and Tuning
an Antenna Gate from
from ID ISC.ANT800/600-DA Antennas
(N70302-xe-ID-B)
11 Device arrangements with the ID ISC.ANT800/600-DA antenna
Depending on the application and the RF regulations applicable in your country, various antenna configurations are possible. Multiple ID ISC.ANT800/600-DA antennas can be combined together with one or more ID ISC.ANT.PS-B power splitters and/or an ID ISC.ANT.MUX multiplexer.
11.1 Standard applications
Standard applications include, in addition to the individual antenna described in Section
10. Startup, antenna configurations in which multiple antennas are combined into a gate. There are
Application Notes for the basic combinations, which in turn can be used to derive additional antenna configurations. The following Application Notes are available:
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 36 of 42
M50101-2de-ID-B.doc
E N G L I S H
11.2 RF regulations in EU countries and the USA
Configuration of the RFID readers and the maximum transmitting power of the antennas are affected mainly by the country-specific RF regulations. For the entire EU the limits are set forth in the R&TTE Directive and EN 300 330. In North America this is regulated by FCC Part 15 (USA) and by the RSS-210 (Canada).
The ID ISC.ANT800/600 antenna with the ID ISC.LRM2500 Reader, when used as intended, complies with the basic requirements of Article 3 and the other relevant clauses of the R&TTE Directive 1999/5/EG of March 1999. This means that operation in the 27 EU countries and the EFTA countries (EU countries plus Switzerland, Norway and Iceland) is possible with a maximum field strength of 42 dBµA/m at 10 m distance.
RF approval (at a maximum field strength of 84 dBµV/m at 30 m) for the ID ISC.ANT800/600 antenna with ID ISC.LRM2500 Reader has been granted in accordance with FCC Part 15 for the USA and the RSS-210 for Canada
RF approval in accordance with EN 300 330 is still possible in all 46 CEPT countries. The CEPT countries are: Albania (ALB), Andorra (AND), Austria (AUT), Azerbaijan (AZE), Belarus (BLR), Belgium (BEL),
Bulgaria (BUL), Bosnia and Herzegovina (BIH), Croatia (HRV), Cyprus (CYP), Czech Republic (CZE), Denmark (DNK), Estonia (EST), Finland (FIN), France (F), Germany (D), Greece (GRC), Hungary (HNG), Iceland (ISL), Ireland (IRL), Italy (I), Latvia (LVA), Liechtenstein (LIE), Lithuania (LTU), Luxembourg (LUX), Malta (MLT), Former Yugoslav Republic of Macedonia (MKD), Moldova (MDA), Monaco (MCO), Netherlands (HOL), Norway (NOR), Poland (POL), Portugal (POR), Romania (ROU), Russian Federation (RUS), San Marino (SMR), Slovak Republic (SVK), Slovenia (SVN), Spain (E), Sweden (S), Switzerland (SUI), Turkey (TUR), Ukraine (UKR), United Kingdom (G), Vatican City (CVA) and Yugoslavia.
The following restrictions are in effect (as of: August 2011): Outside the EU and EFTA countries RF approval must in all cases be applied for. The existing
measuring protocols in accordance with EN 300 330 are generally sufficient.
When starting up, the system integrator should ensure that the prescribed installation instructions are followed, the necessary Reader settings are performed and the allowed limits of the national RF regulations are not exceeded.
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 37 of 42
M50101-2de-ID-B.doc
E N G L I S H
Parameter
Europe
USA / Canada
General
RF-Power – CFG 3
4 W
2 W
ISO15693 Label
RF Modulation – CFG 20
10 %
10%
Downlink RF Data coding – CFG 4 / ISO-MODE / FAST
Normal (1/256)
Normal (1/256) No of Timeslots - CFG 4
1 or 16 Timeslots
1 or 16 Timeslots
11.2.1 Permissible Reader settings
OBID i-scan®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 38 of 42
M50101-2de-ID-B.doc
E N G L I S H
- The two antennas must be mounted directly next to each other and in the same plane
- The two tuners (openings) of the antennas must face out (right and left) and point in one direction.
- Antenna separation (corners) 1cm.
Reader setting
Maximum RF power 4W
Antenna tuner
Jumper settings on ID ISC.DAT antenna tuner
- JP1: open
- JP2: open
- JP3: closed
Power Splitter
with 180° phase rotation
11.2.2 Special antenna construction
In addition to shielding the antennas to conform with national regulations, special antenna constructions can be used to achieve compensation of the magnetic field by means of opposing field directions. This has been tested by FEIG ELECTRONIC GmbH for various antenna constructions and verified in a testing laboratory.
The prerequisite for this is that the antennas be constructed exactly as described. The antennas must be connected to an ID ISC.ANT.PS Power Splitter. To ensure that the complete system stays within the national RF and EMC limits, this must be verified by the system integrator.
Construct the antennas as follows:
Table 4: Construction with two ID ISC.ANT800/600-DA antennas
Notes: Tuning this antenna configuration according to the Application Note:
Configuring and Tuning an Antenna Gate from two ID ISC.ANT800/600-DA Antennas (N50101-xe-ID-B).