Feig Electronic ID ISC.ANT1400/760-A, ID ISC.ANT1400/760-C, ID ISC.ANT1400760-AK, ID ISC.ANT1400/760-B, ID ISC.ANT1400/760-BL Installation Manual

OBID i-scan
®
ID ISC.ANT1400/760
Type A, B and C
INSTALLATION
final public (B) 2006-11-08 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
Note
© Copyright 2006 by
FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
®
OBID
and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
®
my-d
is a registered trademark of Infineon Technologies AG I-CODE Tag-it
®
and mifare® are registered trademarks of Philips Electronics N.V.
TM
is a registered trademark of Texas Instruments Incorporated.
FEIG ELECTRONIC GmbH Page 3 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
Contents
1 Safety Instructions / Warning - Read before Start-Up ! 6
2 Performance Features of the ID ISC.ANT1400/760 Antennas 7
2.1 Available Antenna Types..............................................................................................7
3 Installation and Wiring 8
3.2 Mounting preparation...................................................................................................9
3.3 Installing the Antenna Base .......................................................................................11
3.3.1 Drilling the Mounting Holes ...........................................................................................11
3.3.2 Installing the Antenna Base and Antenna Body............................................................13
3.3.3 Connecting the Components.........................................................................................14
3.4 Installing the Cover Plates..........................................................................................15
4 Typical Antenna Configuration (Gate Antenna with two Antennas) 19
4.1 Project Notes ...............................................................................................................19
4.2 Configuration and Setup using Antennas Type -A and -B......................................21
4.2.1 Required Components ..................................................................................................21
4.2.2 Configuration of a Gate Antenna...................................................................................22
4.2.3 Setting the Power Splitter..............................................................................................23
4.2.4 Setting the Antenna Tuner ............................................................................................23
4.2.5 Reader Configuration....................................................................................................24
4.2.6 Tuning the Gate Antenna ..............................................................................................26
4.3 Configuration and Setup using Antennas Type -C and -B......................................27
4.3.1 Required Components ..................................................................................................27
4.3.2 Configuration of the Gate Antenna, Antenna Type -C and -B.......................................28
4.3.3 Setting the Multiplexer...................................................................................................29
4.3.4 Setting the Antenna Tuner ............................................................................................30
4.3.5 Reader Configuration....................................................................................................31
4.3.6 Tuning the Gate Antenna ..............................................................................................33
4.4 Testing the Gate Antenna...........................................................................................34
FEIG ELECTRONIC GmbH Page 4 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
4.4.1 Checking the Noise Level..............................................................................................34
4.4.2 Reading a Serial Number..............................................................................................35
4.4.3 Testing the performance ...............................................................................................35
4.5 Connecting and Setting the Alarm Kit (optional) .....................................................37
4.5.1 Installing the Alarm Indicators.......................................................................................37
4.5.2 Connecting the Indicators..............................................................................................39
4.5.3 Reader Setting for Indicators.........................................................................................40
4.5.4 Programming a Transponder with the AFI Byte ............................................................42
4.6 Activating Buffered Read Mode.................................................................................44
4.7 Configuring the Reader in accordance with national RF regulations....................45
5 Technical Data 47
5.1 Antenna ID ISC.ANT1400/760- Type A, B and C ......................................................47
5.2 Approval.......................................................................................................................50
5.2.1 Europe (CE) ..................................................................................................................50
5.2.2 USA (FCC) ....................................................................................................................50
5.2.3 USA (UL).......................................................................................................................51
FEIG ELECTRONIC GmbH Page 5 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
1 Safety Instructions / Warning - Read before Start-Up !
The device may only be used for the intended purpose designed by for the manufacturer.
The operation manual should be conveniently kept available at all times for each user.
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device.
Repairs may only be executed by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
When working on devices the valid safety regulations must be observed.
Please observe that some parts of the device may heat severely.
Before touching the device, the power supply must always be interrupted. Make sure that the
device is without voltage by measuring. The fading of an operation control (LED) is no indica­tor for an interrupted power supply or the device being out of voltage!
For installation and dismantling you should wear suitable safety gloves, because parts of an-
tenna housing could be sharp-edged.
CAUTION! The Antenna-Tuner and the Antenna conductor carry voltages up to 1000V.
Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in an immediate proximity of the reader’s antennas for any length of time.
FEIG ELECTRONIC GmbH Page 6 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
2 Performance Features of the ID ISC.ANT1400/760 Antennas
The ID ISC.ANT1400/760 Type A antenna is the version with Reader and Power-Splitter. The ID ISC.ANT1400/760 Type C includes the Reader and Multiplexer. The Reader and Power-Splitter or Multiplexer are mounted inside the antenna base.
The ID ISC.ANT1400/760 Type B antenna is the same antenna without Reader, Power-Splitter or Multiplexer.
Up to
- two antennas (Qty. 1 Type A or C and Qty. 1 Type B or BL) as a single gate,
- three antennas (Qty. 1 Type A or C and Qty. 2 Type B or BL) as a double gate, or
- 4 - 8 antennas (Qty. 1 Type A or C and Qty. 3 - 7 Type B or BL) as a multiple gate
can be operated. Depending on the antenna configuration, one, two or all three read orientations of the Smart Tags
and various antenna spacing (gate widths) are possible. The ID ISC.ANT1400/760 Type A, B and C are „figure-of-eight“ antennas with tuner and have been
optimized as transmitting and receiving antennas for the ID ISC.LR2000 Reader. It is however also possible to operate them with other Readers at a transmission frequency of 13.56 MHz and an output impedance of 50 . The read ranges indicated in this document and the tuning procedures may however then vary.
The antennas comprise the electrical antenna conductor, the housing, the ID ISC.DAT Dynamic Antenna Tuner and the connection cable. The antennas are factory tuned to an impedance of 50 in a magnetically neutral environment at a distance of 95 cm. When installing in different ambient conditions the antenna can be retuned using the “DATuningTool“ PC software. After tuning the antennas will retain their settings as long as the ambient conditions remain unchanged.
The antennas can be used for detecting both product and persons. It is suitable for installation indoors or outdoors if weather-protected.
2.1 Available Antenna Types
The following Antennas are currently available:
Antenna Type Description ID ISC.ANT1400/760-A Antenna with reader ID ISC.LR2000, Power Splitter and Light bar ID ISC.ANT1400/760-B Antenna only with Light bar dummy without LED strip ID ISC.ANT1400/760-BL Antenna only with Light bar and LED strip ID ISC.ANT1400/760-C Antenna with reader ID ISC.LR2000, Multiplexer and Light bar ID ISC.ANT1400760-AK Audio Sounder with mounting accessories
Table 2-2: Available Antenna Types
FEIG ELECTRONIC GmbH Page 7 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
3 Installation and Wiring
3.1 Dimensions of antenna
The outside dimensions of the antenna are shown in Fig. 1
Fig. 1: Antenna outside dimensions
All dimensions are in mm with general tolerance to ISO 2768 m (mean).
FEIG ELECTRONIC GmbH Page 8 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
3.2 Mounting preparation
For assembly the antenna must be carefully unpacked and disassembled into its main components. This is done as described in the following steps:
1. Place the packed antenna on the floor with the top side facing up. Carefully open the box and
remove the side cover plates. Then remove the antenna and at last the side panels.
Fig. 2: Antenna in its packaging Fig. 2a: Side panels in its packaging
2. Carefully put the antenna down again and remove the two fastening brackets in the antenna
foot (Fig. 3). Disconnect the antenna cable from the Multiplexer (Type C) or Power Splitter (Type A) and disassemble the cable for the alarm light in the antenna foot. Then the antenna body can be separated from the antenna foot.
Step 1 Step 2
Fastening brackets
Fig. 3: Separating antenna body from antenna foot
FEIG ELECTRONIC GmbH Page 9 of 50 M50700-4e-ID-B.doc
OBID i-scan
r
®
f Upper frame section
(optional with LED-Strip)
Antenna body with
antenna conducto
Installation ID ISC.ANT1400/760-A/B/C
d Side panels
c Antenna base
(hole template)
Fig. 4: Antenna construction with frame side panels without cover plates
Additionally, at antenna Type A and Type C, some ring cores are added to mount on the cabling (See manual reader).
FEIG ELECTRONIC GmbH Page 10 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
3.3 Installing the Antenna Base
Notes: Before installing the antennas please read 4.1 Project Notes . The spacing of the antennas
comprising a gate depends on the antenna configuration. If multiple antennas or gates are connected to different Readers, a minimum separation of
8 m must be kept between the antennas or gates. For shorter distances (1 m – 8 m) the Readers must be multiplexed. Below a distance of 1.5 m the antennas must also be shielded from each other. Otherwise the Reader range will be significantly reduced. The antennas must have a minimum distance of 20 cm from all larger metal parts! At a distance of less than 50 cm between the antenna and metal parts the Reader range will be significantly reduced.
3.3.1 Drilling the Mounting Holes
If the position of the antennas has been marked or determined, the antenna foot c, which is to be used as a hole template, can be used to mark and drill the mounting holes and the holes for the cable entry. The dimensions are shown in Fig. 5:
Fig. 5: Floor plate dimensions c
All dimensions are in mm with general tolerance to ISO 2768 m (middle).
FEIG ELECTRONIC GmbH Page 11 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
The size and type of the screw anchors depends considerably on the strength of the base or floor. The anchors should be capable of withstanding a permissible load of at least 5 kN per anchor for all load directions (e.g. for concrete floor Hilti HVA anchors with HAS-(E) M8 threaded rod or Hilti HIS-N M8 (5/16”) threaded inserts). The size of the mounting holes in the antenna is 10 mm (.39”). The length of the anchors or bolts should be selected such that they extend at least 50 mm (2.0”) and a maximum of 65 mm (2.6”) from the floor.
Please follow the mounting instructions of the anchor manufacturer!
Two cable openings are provided for the necessary connection cable (see Fig. 5). The cable openings are dimensioned such that up to 10 cables having a diameter of 6 mm can be passed through each opening.
We recommend routing the antenna cables through the cable opening on the Power-Splitter or Multiplexer side. All other cables such as the supply voltage and multiplexing cable should be routed through the cable opening on the Reader side.
Alternatively the cables can be routed through the cutouts provided in the antenna base. The cutouts are shown in Fig. 6
Cutout for cable routing
Fig. 6: Cutout for cable routing
FEIG ELECTRONIC GmbH Page 12 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
3.3.2 Installing the Antenna Base and Antenna Body
The antenna foot is screwed on the floor. Use the adjusting screws (Fig. 7) to align the antenna foot vertically.
Adjusting screws (hexagon socket width A/F5) Fig. 7: Attaching and aligning the antenna foot
The antenna body is connected to the antenna foot and attached to the antenna foot using the fastening brackets as shown in (Fig. 8). The antenna body may be inserted 180° rotated (Fig. 8) . Both antennas must installed in the same direction and parallel orientation.
Fig. 8: Connecting antenna base to antenna foot
Fastening brackets Fastening brackets
Fig. 9: Fastening antenna base to antenna foot
FEIG ELECTRONIC GmbH Page 13 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
3.3.3 Connecting the Components
The antenna is for the most part pre-wired. Only the antenna cables for the Type B or BL antennas need to be routed to the main antenna (Type A or C). At 4.2.2.a typical configuration for Type A and B antennas is shows (4.3.2 for Type C and B antennas). The 24V supply is brought to the terminal (observe polarity).
Fig. 10: Terminal for 24V supply voltage
The cable routing should be as short and compact as possible regardless of the antenna configuration. The cables are finally tied together in small loops. Tie the cables as far away from the antenna conductor as possible. The cables should never be allowed to touch the copper tube. The coaxial antenna cables have fixed lengths and may not be shortened. Fig. 11 shows a corresponding cable configuration.
Fig. 11: Cable Wrapping in Antenna Base
FEIG ELECTRONIC GmbH Page 14 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
3.4 Installing the Cover Plates
Note: We recommend installing the cover plates only after a function test of the complete antenna
configuration.
Fig. 12 shows the cover plates g and h as well as the frame side sections i. The upper frame section is already sitting on the antenna body as described in Fig. 26.
h Cover plate with
painted finish
g Unpainted cover
plate
Fig. 12: Installing the cover plates
i Side panels
FEIG ELECTRONIC GmbH Page 15 of 50 M50700-4e-ID-B.doc
OBID i-scan
®
Installation ID ISC.ANT1400/760-A/B/C
Proceed according to the following steps to install the cover plates g and h and side panels i:
1. Fit cover plates into antenna foot and upper frame section as shown in Fig. 13. Cover plates
with the painted, non-transparent area go on the open side of the antenna body. This covers the antenna conductor and electronics.
Fig. 13: Cover plates in antenna foot and upper frame section
FEIG ELECTRONIC GmbH Page 16 of 50 M50700-4e-ID-B.doc
Loading...