With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this manual has been done to the best of our knowledge.
FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The installation instructions given in this manual are based on advantageous boundary conditions.
FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.
®
OBID
and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
®
my-d
is a registered trademark of Infineon Technologies AG
I-CODE
Tag-it
®
and mifare® are registered trademarks of Philips Electronics N.V.
TM
is a registered trademark of Texas Instruments Incorporated.
FEIG ELECTRONIC GmbHPage 3 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
Contents
1Safety Instructions / Warning - Read before Start-Up !6
2Performance Features of the ID ISC.ANT1400/760 Antennas7
5.2.1 Europe (CE) ..................................................................................................................50
5.2.2 USA (FCC) ....................................................................................................................50
5.2.3 USA (UL).......................................................................................................................51
FEIG ELECTRONIC GmbHPage 5 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
1 Safety Instructions / Warning - Read before Start-Up !
• The device may only be used for the intended purpose designed by for the manufacturer.
• The operation manual should be conveniently kept available at all times for each user.
• Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
• The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
• Repairs may only be executed by the manufacturer.
• Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
• Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
• When working on devices the valid safety regulations must be observed.
• Please observe that some parts of the device may heat severely.
• Before touching the device, the power supply must always be interrupted. Make sure that the
device is without voltage by measuring. The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being out of voltage!
• For installation and dismantling you should wear suitable safety gloves, because parts of an-
tenna housing could be sharp-edged.
CAUTION! The Antenna-Tuner and the Antenna conductor carry voltages up to
1000V.
Special advice for wearers of cardiac pacemakers:
• Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in
an immediate proximity of the reader’s antennas for any length of time.
FEIG ELECTRONIC GmbHPage 6 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
2 Performance Features of the ID ISC.ANT1400/760 Antennas
The ID ISC.ANT1400/760 Type A antenna is the version with Reader and Power-Splitter. The
ID ISC.ANT1400/760 Type C includes the Reader and Multiplexer. The Reader and Power-Splitter
or Multiplexer are mounted inside the antenna base.
The ID ISC.ANT1400/760 Type B antenna is the same antenna without Reader, Power-Splitter or
Multiplexer.
Up to
- two antennas (Qty. 1 Type A or C and Qty. 1 Type B or BL) as a single gate,
- three antennas (Qty. 1 Type A or C and Qty. 2 Type B or BL) as a double gate, or
- 4 - 8 antennas (Qty. 1 Type A or C and Qty. 3 - 7 Type B or BL) as a multiple gate
can be operated.
Depending on the antenna configuration, one, two or all three read orientations of the Smart Tags
and various antenna spacing (gate widths) are possible.
The ID ISC.ANT1400/760 Type A, B and C are „figure-of-eight“ antennas with tuner and have been
optimized as transmitting and receiving antennas for the ID ISC.LR2000 Reader. It is however also
possible to operate them with other Readers at a transmission frequency of 13.56 MHz and an
output impedance of 50 Ω. The read ranges indicated in this document and the tuning procedures
may however then vary.
The antennas comprise the electrical antenna conductor, the housing, the ID ISC.DAT DynamicAntenna Tuner and the connection cable. The antennas are factory tuned to an impedance of 50 Ω
in a magnetically neutral environment at a distance of 95 cm. When installing in different ambient
conditions the antenna can be retuned using the “DATuningTool“ PC software. After tuning the
antennas will retain their settings as long as the ambient conditions remain unchanged.
The antennas can be used for detecting both product and persons. It is suitable for installation
indoors or outdoors if weather-protected.
2.1 Available Antenna Types
The following Antennas are currently available:
Antenna TypeDescription
ID ISC.ANT1400/760-AAntenna with reader ID ISC.LR2000, Power Splitter and Light bar
ID ISC.ANT1400/760-BAntenna only with Light bar dummy without LED strip
ID ISC.ANT1400/760-BLAntenna only with Light bar and LED strip
ID ISC.ANT1400/760-CAntenna with reader ID ISC.LR2000, Multiplexer and Light bar
ID ISC.ANT1400760-AKAudio Sounder with mounting accessories
Table 2-2: Available Antenna Types
FEIG ELECTRONIC GmbHPage 7 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
3 Installation and Wiring
3.1 Dimensions of antenna
The outside dimensions of the antenna are shown in Fig. 1
Fig. 1: Antenna outside dimensions
All dimensions are in mm with general tolerance to ISO 2768 m (mean).
FEIG ELECTRONIC GmbHPage 8 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
3.2 Mounting preparation
For assembly the antenna must be carefully unpacked and disassembled into its main
components. This is done as described in the following steps:
1. Place the packed antenna on the floor with the top side facing up. Carefully open the box and
remove the side cover plates. Then remove the antenna and at last the side panels.
Fig. 2: Antenna in its packagingFig. 2a: Side panels in its packaging
2. Carefully put the antenna down again and remove the two fastening brackets in the antenna
foot (Fig. 3). Disconnect the antenna cable from the Multiplexer (Type C) or Power Splitter
(Type A) and disassemble the cable for the alarm light in the antenna foot. Then the antenna
body can be separated from the antenna foot.
Step 1Step 2
Fastening brackets
Fig. 3: Separating antenna body from antenna foot
FEIG ELECTRONIC GmbHPage 9 of 50M50700-4e-ID-B.doc
OBID i-scan
r
®
f Upper frame section
(optional with LED-Strip)
Antenna body with
antenna conducto
InstallationID ISC.ANT1400/760-A/B/C
d Side panels
c Antenna base
(hole template)
Fig. 4: Antenna construction with frame side panels without cover plates
Additionally, at antenna Type A and Type C, some ring cores are added to mount on the cabling
(See manual reader).
FEIG ELECTRONIC GmbHPage 10 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
3.3 Installing the Antenna Base
Notes:
Before installing the antennas please read 4.1 Project Notes . The spacing of the antennas
comprising a gate depends on the antenna configuration.
If multiple antennas or gates are connected to different Readers, a minimum separation of
8 m must be kept between the antennas or gates. For shorter distances (1 m – 8 m) the
Readers must be multiplexed. Below a distance of 1.5 m the antennas must also be shielded
from each other. Otherwise the Reader range will be significantly reduced. The antennas
must have a minimum distance of 20 cm from all larger metal parts! At a distance of less
than 50 cm between the antenna and metal parts the Reader range will be significantly
reduced.
3.3.1 Drilling the Mounting Holes
If the position of the antennas has been marked or determined, the antenna foot c, which is to be
used as a hole template, can be used to mark and drill the mounting holes and the holes for the
cable entry. The dimensions are shown in Fig. 5:
Fig. 5: Floor plate dimensions c
All dimensions are in mm with general tolerance to ISO 2768 m (middle).
FEIG ELECTRONIC GmbHPage 11 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
The size and type of the screw anchors depends considerably on the strength of the base or floor.
The anchors should be capable of withstanding a permissible load of at least 5 kN per anchor for
all load directions (e.g. for concrete floor Hilti HVA anchors with HAS-(E) M8 threaded rod or Hilti
HIS-N M8 (5/16”) threaded inserts). The size of the mounting holes in the antenna is 10 mm (.39”).
The length of the anchors or bolts should be selected such that they extend at least 50 mm (2.0”)
and a maximum of 65 mm (2.6”) from the floor.
Please follow the mounting instructions of the anchor manufacturer!
Two cable openings are provided for the necessary connection cable (see Fig. 5). The cable
openings are dimensioned such that up to 10 cables having a diameter of 6 mm can be passed
through each opening.
We recommend routing the antenna cables through the cable opening on the Power-Splitter or
Multiplexer side. All other cables such as the supply voltage and multiplexing cable should be
routed through the cable opening on the Reader side.
Alternatively the cables can be routed through the cutouts provided in the antenna base. The
cutouts are shown in Fig. 6
Cutout for cable routing
Fig. 6: Cutout for cable routing
FEIG ELECTRONIC GmbHPage 12 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
3.3.2 Installing the Antenna Base and Antenna Body
The antenna foot is screwed on the floor. Use the adjusting screws (Fig. 7) to align the antenna
foot vertically.
Adjusting screws (hexagon socket width A/F5)
Fig. 7: Attaching and aligning the antenna foot
The antenna body is connected to the antenna foot and attached to the antenna foot using the
fastening brackets as shown in (Fig. 8). The antenna body may be inserted 180° rotated (Fig. 8) .
Both antennas must installed in the same direction and parallel orientation.
Fig. 8: Connecting antenna base to antenna foot
Fastening brackets Fastening brackets
Fig. 9: Fastening antenna base to antenna foot
FEIG ELECTRONIC GmbHPage 13 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
3.3.3 Connecting the Components
The antenna is for the most part pre-wired. Only the antenna cables for the Type B or BL antennas
need to be routed to the main antenna (Type A or C). At 4.2.2.a typical configuration for Type A
and B antennas is shows (4.3.2 for Type C and B antennas). The 24V supply is brought to the
terminal (observe polarity).
Fig. 10: Terminal for 24V supply voltage
The cable routing should be as short and compact as possible regardless of the antenna
configuration. The cables are finally tied together in small loops. Tie the cables as far away from
the antenna conductor as possible. The cables should never be allowed to touch the copper tube.
The coaxial antenna cables have fixed lengths and may not be shortened. Fig. 11 shows a
corresponding cable configuration.
Fig. 11: Cable Wrapping in Antenna Base
FEIG ELECTRONIC GmbHPage 14 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
3.4 Installing the Cover Plates
Note:
We recommend installing the cover plates only after a function test of the complete antenna
configuration.
Fig. 12 shows the cover plates g and h as well as the frame side sections i. The upper frame
section is already sitting on the antenna body as described in Fig. 26.
h Cover plate with
painted finish
g Unpainted cover
plate
Fig. 12: Installing the cover plates
i Side panels
FEIG ELECTRONIC GmbHPage 15 of 50M50700-4e-ID-B.doc
OBID i-scan
®
InstallationID ISC.ANT1400/760-A/B/C
Proceed according to the following steps to install the cover plates g and h and side panels i:
1. Fit cover plates into antenna foot and upper frame section as shown in Fig. 13. Cover plates
with the painted, non-transparent area go on the open side of the antenna body. This covers
the antenna conductor and electronics.