Feig Electronic CPR46 User Manual

Annex no. 5
Functional Description /
User Manual
Date: 2012-06-11 Vers. no. 1.12
m. dudde hochfrequenz-technik
Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920
INSTALLATION
ID CPR46.10 - OBID myAXXESS® flatOne
ISO14443-A and -B, NFC Payment Reader
preliminary - confidential 2013-01-14 - M20514-4e-ID-B.doc
OBID® classic-pro Installation ID CPR46.10
Note
© Copyright 2012 by
FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice.
The reproduction, distribution and utilization of this document as well as the communi cation of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this ma­nual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cros s environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
®
OBID
and OBID i-scan® is a registered trademark of FEIG ELECTRONIC GmbH.
All brand names, trademarks or logos are property of their respe ctive owners.
Contact:
Commercial Questions: obid@feig.de Technical Questions: obid-support@feig.de
FEIG ELECTRONIC GmbH Page 2 of 19 M20514-4e-ID-B.doc
OBID® classic-pro Installation ID CPR46.10
Contents
1. Safety Instructions / Warning - Read before start-up ! 4
2. Characterization ID CPR46.10 5
2.1. Versions / Ordering Information's ...................................................................................... 6
2.2. Delivery Content ................................................................................................................... 6
2.3. Technical Data ...................................................................................................................... 7
2.4. Dimensions ......................................................................................................................... 10
3. Mechanical Installation 11
3.1. Recommended Front Panel Cutout .................................................................................. 12
3.2. Mounting in Metallic and Nonmetallic Front Panels ....................................................... 13
3.3. Recommended Mounting Frame ....................................................................................... 14
4. Wiring and Electrical Connection 15
4.1. Connection X1, X2 .............................................................................................................. 15
4.2. Standby / Wakeup .............................................................................................................. 16
4.3. SAM Socket (ID CPR46.10-4SUSB only) .......................................................................... 17
4.4. LEDs .................................................................................................................................... 18
5. Radio Approvals 19
5.1. Europe (CE) ......................................................................................................................... 19
FEIG ELECTRONIC GmbH Page 3 of 19 M20514-4e-ID-B.doc
OBID® classic-pro Installation ID CPR46.10
1. Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the
manufacturer.
The operation manual should be conveniently kept available at all times for each user.
Unauthorised changes and the use of spare parts and additional devices which have not
been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorised measures shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase
are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device.
Repairs may only be executed by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by
qualified personnel.
Use of the device and its installation must be in accordance with national legal
requirements and local electrical codes .
When working on devices the valid safety regulations must be observed.
Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pace­maker and not stay in an immediate proximity of the device respective the antenna for some time.
FEIG ELECTRONIC GmbH Page 4 of 19 M20514-4e-ID-B.doc
OBID® classic-pro Installation ID CPR46.10
2. Characterization ID CPR46.10
The OBID® classic-pro ID CPR46.10 is a transparent EMVCo Level 1 approved contactless RFID card reader for unattended electronic payment-, eTicket- or eMobility- Applications.
The reader is explicitly designed to be nearly flat installed into a metallic front panel from the back side like vending machines, ticket machines, petrol- or charging stations, etc. If mounted in nonme­tallic front plates an additional 2 mm steel frame has to be used. The robust and flat housing front panel ensures a good protection against water, dust and vandalism.
The ID CPR46.10 supports all common contactless credit and debit cards as well as all other common ISO14443-A and -B based smart cards and can communicate with NFC devices running in card emulation mode.
The reader offers high security authentication and encryption. Data transfer between the reader and the host is AES256 encrypted.
Fig. 1 ID CPR46.10 front view - not installed
Fig. 2 ID CPR46.10 Front view and rear view with closed and open hatch to SAM sockets
FEIG ELECTRONIC GmbH Page 5 of 19 M20514-4e-ID-B.doc
Loading...
+ 14 hidden pages