Fedders CH18ABD1VF, CH30ACD1VF, CH24ACD1VF, CH42ACD1VF, CH60ACZ1VF User Manual

...
Residential & Light Commercial HVAC
Split System Heat Pump
11⁄2 thru 5 Tons
208/230 Volt, 1-Phase, 60 Hz
Performance:
Efficiency rating of 13 SEER
Cooling capacities from 1
Refrigerant Circuit:
Factory installed biflow liquid line filter drier
Long life copper tubes, aluminum fins
State-of-the-art compressors
Large, wrap-around coil surface
2 to 5 tons
Quality Built:
Galvanized steel exterior cabinet with 1,000-hour salt spray, powder-coated finish
Powder-coated fan guard
Full louvered panel to protect coil
Formed base with 2
Limited 5-y
ear warranty on par
2" ground c
learance
ts
Low pressure port
Integrated solid state control with adjustable
emp demand defrost
ime-t
t
Easy To Install:
F
a
c
Rated in Accordance with ARI Standard 210/240. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org
Model
Number
CH18ABD1VF 11⁄2 R-22 18,000 13.5 20 32 1⁄2 X 21 1⁄2 X 21 1⁄2 24 x 24 132 / 127
CH24ACD1VF 2 R-22 24,000 16.0 25 32 1⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32 195 / 186
CH30ACD1VF 21⁄2 R-22 30,000 18.8 30 32 1⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32 195 / 186
CH36ACD1VF 3 R-22 36,000 20.5 35 32 1⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32 197 / 188
CH42ACD1VF 31⁄2 R-22 42,000 24.8 40 32 1⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32 208 / 201
CH48ACD1VF 4 R-22 48,000 27.3 45 32 1⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32 212 / 203
CH60ACZ1VF 5 R-410A 60,000 38.4 60 39 X 29 1⁄2 X 29 1⁄2 32 x 32 258 / 249
Size
(tons)
Refrigerant
Nominal
BTUH
Min. Circuit
Ampacity
2Max. Fuse
eaker
or Br
tory-charged
ews to access electrical controls
e scr
e
y thr
Onl
Easy access to service valves
Operating Dimensions
H x W x D (inches)
Min. Mounting
Pad Size (inches)
Ship / Operating
Weight (lbs)
Product Specifications
PHYSICAL DATA
MODEL SIZE
PERFORMANCE DATA
NOMINAL CAPACITY (BTUH) 18,000 24,000 30,000 36,000 42,000 48,000 60,000
FAN DATA
FAN MOTOR TYPE PSC PSC PSC PSC PSC PSC PSC
HP 1/5 1/3 1/3 1/3 1/3 1/3 1/3
DIAMETER 18" 22" 22" 22" 22" 22" 24"
BLADE 3 3 3 3 3 3 3
RPM 1,050 1,050 1,050 1,050 1,050 1,050 950
CFM 1,800 3,400 3,400 3,400 3,400 3,400 4,000
OUTDOOR COIL
TYPE Enhanced Aluminum Plate Fin / Rifled Copper Tube
COIL FACE AREA (ft2) 12.2 18.2 18.2 18.2 18.2 18.2 22.2
O.D. 3/8" 7mm 7mm 7mm 7mm 7mm 7mm
FPI / ROWS 18 -1 18-2 18 -2 18 -2 18-3 18-3 18-3
ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V)
MINIMUM CIRCUIT AMPACITY - MCA (amps)
MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP(amps)
COMPRESSOR RLA (Rated Load Amps) 10.0 11.4 13.6 15 18.4 20.9 29.4
COMPRESSOR LRA (Locked Rotor Amps) 41 56 67 73 95 109 134
FAN MOTOR FLA (Full Load Amps) 1.4 1.8 1.8 1.8 1.8 1.8 1.9
REFRIGERANT CONNECTIONS
LIQUID LINE CONNECTION SIZE (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8
SUCTION LINE CONNECTION SIZE
RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8
RECOMMENDED LINE SET SUCTION DIAMETER (In. OD) 3/4 3/4 7/8 7/8 7/8 1 1/8 1 1/8
FACTORY CHARGE - OZ. 103 164 154 164 207 233 233*
(In. OD)
2
18 24 30 36 42 48 60
13.5 16.0 18.8 20.5 24.8 27.3 38.5
3
20 25 30 35 40 45 50
3/4 3/4 7/8 7/8 7/8 7/8 7/8
NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. ALL motors/compressors contain internal overload protection.
1. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
2. Time delay fuses may be used in place of HACR circuit breaker.
* Unit uses R-410A refrigerant.
2
Specifications subject to change without notice.