FasTest TwistMate Serie User Manual

PIECE
PISTON / SLEEVE
PIECE
PISTON / SLEEVE
RING
OPERATING INSTRUCTIONS
MIT / MITH Connectors
DESCRIPTION: Quick connectors for Female Threads.
PLUG MALE
CONNECTOR STYLE
THREADED MALE
CONNECTOR STYLE
Note: Shown to the right is the THREADED MALE SWIVEL CONNECTOR. Swivel connector operates the same as the THREADED MALE CONNECTOR shown above.
Please thoroughly read the instructions prior to operating the connector. The connectors are designed to provide a safe, reliable leak-tight seal and connection when properly maintained and operated.
The connector is designed to mate with a specific application. Verify the application prior to the introduction of pressure or processing. Use only in a safe environment. Safety chains and guards are recommended for all applications.
Connectors are NOT designed for permanent connections and are for temporary connections only. Inadvertent loosening and loss of media may result when used as a permanent connection.
Connectors are not internally valved and will not prevent loss of media when disconnected.
DO NOT EXCEED pressure rating as marked on connector or corresponding literature. Operating pressure rating based on tests using NPTF threads (to SAE J476a Dryseal specifications) of cold drawn steel. Material or thread deviations may reduce working pressure and should be verified by test.
FEMALE TEST PRESSURE CONNECTION PORT
FINGER TIGHT THREAD IN ACTUATION
PRESSURE
FINGER TIGHT THREAD IN ACTUATION
PRESSURE
MAIN SEAL
TEST PRESSURE
CUSTOMER TEST
MAIN SEAL
CUSTOMER TEST
OPERATION:
1. Fasten connector securely to pressure supply line or manifold by threading connector wrench-tight using wrench flats on body or hex flats on swivel unit. NOTE: Plug style connectors do not require wrench-tightening.
2. Thread connector finger-tight onto test piece until Main Seal contacts test piece.
3. Introduce test pressure to . Connector will automatically seal when internal pressure is applied.
4. Perform evacuation / filling operations.
5. To remove, release test pressure and thread off connector.
CONNECTOR MAINTENANCE:
A daily, weekly and periodic inspection of the connector by competent person is recommended.
o User must establish a regular interval for maintenance as determined by the user media and
operational environment.
o Inspection should include damage to the body missing or loose components, leak tightness,
Inspect threads for wear.
Use only original FasTest spare parts that are designed for the application and are subject to strict
FasTest recommends a daily visual inspection of the main seal located in the front of the sleeve.
Lubricate on regular intervals under normal operating conditions. Lubrication should be compati-
ease of operation, sufficient lubrication, wear, dirt accumulation and damage.
quality control. See warranty.
Inspect for tears or cracks in the seal surface. Replace the main seal if tears or cracks are visible.
ble with user application.
MIT CONNECTOR
BACK-UP
BACK-UP
WRENCH FLATS
BODY
SLEEVE
MAIN SEAL
FasTest, Inc. Product Warranty
FasTest, Inc. warrants its products against defects of workmanship and/or material for 12 months from the date of the sale by FasTest, Inc. This warranty is void if the product is misused, tampered with or used in a manner that is not in accordance with FasTest, Inc. recommendations and/or instructions. FasTest, Inc. is not liable for consequential or other damages including, but not limited to, loss, damage, personal injury, or any other expense directly or indirectly arising from the use of or inability to use its products either separately or in combination with other products. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, WHETHER ORAL OR WRITTEN, INCLUDING BUT NOT LIMITED TO WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Remedy under this warranty is limited to replacement of the product or an account credit in the amount of the original selling price, at the option on FasTest, Inc. All allegedly defective products must be returned prepaid transportation to FasTest, Inc. along with information describing the products performance, unless disposition in the field is authorized in writing by FasTest, Inc.
www.fastestinc.com
Roseville, MN Ph 1-800-444-2373 Fax 651-645-7390
CONNECTOR
STYLE
OPERATING INSTRUCTIONS
Female Connection Port Installation:
This applies to the following two styles. Threaded Male and Swivel Male Connectors.
FEMALE PORT
THREADED MALE
SWIVEL MALE
CONNECTOR STYLE
FEMALE PORT
1. Whatever type of fitting you connect to our female port, you must use a ‘thread sealant’ and tighten to a maximum of 15 ft-lbs.
See examples
below and right.
THREAD SEALANT
Ex. CONNECTION
15 FT-LBS
THREAD SEALANT
15 FT-LBS
Ex. CONNECTION
www.fastestinc.com
Roseville, MN Ph 1-800-444-2373 Fax 651-645-7390
Loading...