REPLACMENT INSTRUCTIONS
Seal Set Instructions for FE Model External Connector
Caution –
1. Periodically inspect connector, seals and washers for wear or damage. Replace worn
FOLLOW DIRECTIONS given here and the Operating Installation instructions with the FE
Connector to insure a safe, secure seal.
HOUSING
or damaged connector seal sets to prevent loss of seal ability and personal injury.
2. If replacing seals only, inspect washers for warping, corrosion or excessive wear.
3. Replace complete Fastest main seal set if washers are warped, corroded or worn.
SET SCREW
SEE CHART
SPANER
WRENCH
HOLE
PISTON
WASHER
MAIN SEAL
MAIN SEAL
WASHER
Diagram 1
SEAL CASING
*Seal Set Parts Required
Connector Number of Seals Number of Washers
FE01 1 2
FE1 1 2
FE2 2 2
FE3, FE4 3 2
FE5, FE6 3 2
FE-NPT seal sets also contain face seal and spacers as needed. See other side for FE-NPT seal
set replacement instructions.
Installation of Seals
1. For seal replacement, loosen set screw on side of housing.
2. Unscrew seal casing and remove (counterclockwise). A spanner wrench hole is provided
for breaking the seal casing loose if required.
3. Seal set contains elastomer seals and backup washers per chart.
4. Verify that seals and washers are the same size.
WARNING: Seals and washers must have the same outside and inside diameters. Use of
incorrect size seals or washers will result in the loss of seal ability.
5. Assemble/load seal set into seal casing per Diagram 1.
6. Reassemble/screw the seal casing into the housing.
7. Retighten set screw.
WARNING: If instructions are not clear or components are missing, contact factory before
using connector.
Roseville, MN
Phone: 1-800-444-2373
Fax: 651-645-7390
www.fastestinc.com
WP005 3/10/2009
REPLACMENT INSTRUCTIONS
Seal Set Instructions for FE-NPT Model External
Connector
This instruction sheet is to be used as a supplement to the standard FE
seal set instructions (side one). Read both instruction sheets carefully
before installing the FE-NPT seal set.
1. FE-NPT seal sets contain one 3/8” thick urethane main seal (A), back up washers (B),
and metal spacers (C) as needed. Seals are also available in packages of five seal
HOUSING
changes with locking rings (Bulk Pack).
2. Assemble NPT seal set per Diagram 2 and reassemble connector as directed in the
FE connector
3. FE-NPT seal sets require up to 600 psi pilot pressure to actuate the seal. A Fastest
pilot pressure booster *(PB-1-15) or other hydraulic pressure source is needed to
reach, but not to exceed 600 psi. The pilot pressure should always be adjusted to the
lowest pressure that will give a consistent seal.
PISTON
SET SCREW
(C) SPACER
WASHER
(A) MAIN SEAL
(URETHANE)
Diagram 2
(B) WASHER
FE – NPT
SEAL SET
SEAL CASING
SPANER
WRENCH
HOLE
*PB-1015 pilot pressure booster operates using up to 65 psi air pressure inlet, yielding up to 600 psi
outlet hydraulic pressure. Please refer to the Fastest catalog for additional information.
Note: Other thread sizes or special applications are available upon request.
WARNING: If instructions are not clear or components are missing, contact factory before using
connector.
FasTest, Inc. Product Warranty
FasTest, Inc. warrants its products against defects of workmanship and/or material for 1 year from the date
of the sale by FasTest, Inc. This warranty is void if the product is misused, tampered with or used in a
manner that is not in accordance with FasTest, Inc. recommendations and/or instructions. FasTest, Inc. is
not liable for consequential or other damages including, but not limited to, loss, damage, personal injury, or
any other expense directly or indirectly arising from the use of or inability to use its products either separately
or in combination with other products. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, WHETHER
ORAL OR WRITTEN, INCLUDING BUT NOT LIMITED TO WARRANTIES OR MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
Remedy under this warranty is limited to replacement of the product or an account credit in the amount of the original
selling price, at the option on FasTest, Inc. All allegedly defective products must be returned prepaid transportation to
FasTest, Inc. along with information describing the products performance, unless disposition in the field is authorized in
writing by FasTest, Inc.
Roseville, MN
Phone: 1-800-444-2373
Fax: 651-645-7390
www.fastestinc.com