FasTest CalMate Series User Manual

OPERATING INSTRUCTIONS
Connector Maintenance:
A daily, weekly and periodic inspection of the conne
person is recommended. User must establish a regular interval for maintenance as determined by the user media and operational environment.
Difficulty of operation after continual use indicates
or other maintenance.
Use only original FasTest spare parts that are designed for the
application and are subject to strict quality control. See Warranty.
Safety Warnings – Guidelines:
If instructions are not completely understood by operator or components
are missing, contact FasTest before attempting use of the connector.
FasTest Connectors are not internally valved, and will not prevent loss of
media when disconnected. Do not attempt to disconnect unless safe conditions are met.
FasTest Connectors must only be used with test pieces of a specific size
as indicated by the part number. Improper use could cause separation of the connector from the test piece resulting in physical harm or damage.
c
tor by competent
a need for lubrication
FasTest, Inc. Product Warranty
FasTest, Inc. warrants its products against defects of workmanship and/or material for 12 months sale by FasTest, Inc. This warranty is void if the product is misused, tampered with or used in a manner that is not in accordance with FasTest, Inc. recommendations and/or instructions. FasTest, Inc. is not liable for consequential or other damages including, but not limited to, loss, damage, personal injury, or any other expense directly or indirectly arising from the use of or inability to use its products either separately or in combination with other products. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, WHETHER ORAL OR WRITTEN, INCLUDING BUT NOT LIMITED TO WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Remedy under this warranty is limited to replacement of the product or an account credit in the amount of the original selling price, at the option on FasTest, Inc. All allegedly defective products must be returned prepaid transportation to FasTest, Inc. along with information describing the products performance, unless disposition in the field is authorized in writing by FasTest, Inc.
from the date of the
CalMate (SA) Ferrule Connectors
Description:
CalMate Series Ferrule Connectors Seal on
Sanitary Tube Fittings.
1/8” NPT TEST
PORT
CalMate Connectors provide a reliable leak-tight connection
hat grips ands seals on ferrule fittings and gaskets. Simply
t insert ferrule fitting and twist sleeve until tight.
Please thoroughly read and understand these operating instructions prior to operating the connector. The use of pressurized media for sealing and testing requires a thorough understanding of the FasTest CalMate Operating Instructions.
Roseville, MN Ph: 1-800-444-2373 Fax: 651-645-7390
www.fastestinc.com
OPERATING INSTRUCTIONS
Installation:
Connect securely to the 1/8” NPT termination port of
the connector.
Operation:
Connecting Action:
1. Move the sleeve back to disengage the connector. Holding the wrench flat end of the connector push the connector onto the test piece and gasket.
Back Side Face
of Test Piece
Test Piece
2. Slide sleeve completely forward.
his will collapse the gripping balls.
T
Sleeve Back
Gasket
Sleeve Back
Wrench Flats
Sleeve Notch
Sleeve Forward
3. Rotate the sleeve clockwise until hand tight for locking engagement. (NOTE: NOTICE LOCATION OF SCREW HEAD) The connector will be properly engaged when gripping balls are tight against the back side face of test piece.
Clockwise
C
AUTION: The maximum rated pressure is stamped on the connector sleeve. Before using, verify that this pressure rating is within your working pressures.
WARNING: Tug on the connector to assure proper engagement and
gripping before introduction of pressurized media.
DO NOT force connector onto test part when connecting. The insertion
into the part and the forward motion of the sleeve should easily mate with the test piece. Forcing the connector will result in poor sealing and possible leakage.
DO NOT turn or rotate connector after the engagement to test piece.
Damage to the test part and the connector’s internal parts may result.
4. Activate test media through connector test port.
Disconnecting Action:
. Deactivate test pressure.
1
2. Rotate sleeve counter-clockwise about ¼ turn, then pull the sleeve all the way back. Separate connector from test piece and gasket.
Rotate Sleeve CCW Sleeve Back
Roseville, MN Ph: 1-800-444-2373 Fax: 651-645-7390