Model 88C Resistivity Meter
Instruction Manual
© 2017 Fann Instrument Company, Inc
Manual No. 207980, Revision F
Instrument No. 207960
![](/html/6f/6fcf/6fcfe37438a6c285c13abd12af0cb5cd5c9f22bd7b5515b6a0e1f4e5dc2a9944/bg2.png)
Model 88C Resistivity Meter Instruction Manual
©2017 Fann Instrument Company
Houston, Texas, USA
All rights reserved. No part of this work covered by the copyright hereon may be reproduced or
copied in any form or by any means (graphic, electronic, or mechanical) without first receiving the
written permission of Fann Instrument Company, Houston, Texas, USA.
Printed in USA.
The information contained in this document includes concepts, methods, and apparatus which may be
covered by U.S. Patents. Fann Instrument Company reserves the right to make improvements in
design, construction, and appearance of our products without prior notice.
®
FANN
States and/or other countries. All other trademarks mentioned in the operating instructions are the
exclusive property of the respective manufacturers.
Contact Fann Instrument Company
and the FANN logo are registered trademarks of Fann Instrument Company in the United
1- 800-347-0450
P.O. Box 4350
Houston, Texas, 77210 USA
14851 Milner Road, Gate 5
Houston, Texas, 77032, USA
fannmail@fann.com
207980 Revision F, October 201 7 2
![](/html/6f/6fcf/6fcfe37438a6c285c13abd12af0cb5cd5c9f22bd7b5515b6a0e1f4e5dc2a9944/bg3.png)
Model 88C Instruction Manual
Table of Contents
1 Introduction ............................................................................................................... 4
1.1 Document Conventions .................................................................................... 4
2 Safety ....................................................................................................................... 6
2.1 Battery Safety ................................................................................................... 6
3 Features and Specifications ...................................................................................... 7
4 Operation .................................................................................................................. 9
4.1 Fluid Samples ................................................................................................... 9
4.2 Semisolid Samples ......................................................................................... 10
5 Troubleshooting and Maintenance .......................................................................... 12
5.1 Calibration ...................................................................................................... 12
5.2 Battery Replacement ...................................................................................... 12
5.3 Cleaning ......................................................................................................... 13
6 Parts List................................................................................................................. 14
7 Warranty and Returns ............................................................................................. 15
7.1 Warranty ......................................................................................................... 15
7.2 Returns ........................................................................................................... 15
List of Figures
Figure 3-1 Resistivity Meter, Model 88C .......................................................................... 8
Figure 4-1 Resistivity Chart for Na Cl Solu tions .............................................................. 11
List of Tables
Table 3-1 Resistivity Meter, Model 88C Specifications .................................................... 7
Table 3-2 Range of Environmental Conditions ................................................................ 7
Table 6-1 Model 88 Resistivity Meter Included Parts .................................................... 14
Table 6-2 Optional Equipment ....................................................................................... 14
207980 Revision F, October 2017 3
![](/html/6f/6fcf/6fcfe37438a6c285c13abd12af0cb5cd5c9f22bd7b5515b6a0e1f4e5dc2a9944/bg4.png)
Model 88C Instruction Manual
1 Introduction
The Model 88C Resistivity Meter measures the resistivity of fluids, slurries, and
semisolids according to API recommended practice. Field and laboratory personnel
rely on this instrument to evaluate formation characteristics from electric logs.
Resistivity is the ability of a material to resist conduction; conductivity is the
reciprocal of resistivity.
1.1 Document Conventions
The following icons are used as necessary in this instruction manual.
NOTE. Notes emphasize additional informat ion that may be
useful to the reader.
CAUTION. Describes a situation or practice that requires operator
awareness or action in order to avoid undesirable consequences.
MAN D AT O R Y AC TION. Gives directions that, if not observed,
could result in loss of data or in damage to equipment.
WARNING! Describes an unsafe condition or practice that if not
corrected, could result in personal injury or threat to health.
ELECTRICITY WARNING! Alert s t he operator that there is risk of
electric shock.
207980 Revision F, October 2017 4
![](/html/6f/6fcf/6fcfe37438a6c285c13abd12af0cb5cd5c9f22bd7b5515b6a0e1f4e5dc2a9944/bg5.png)
Model 88C Instruction Manual
HOT SURFACE! Alerts the operator that there is a hot surface and
that there is risk of getting burned if the surface is touched.
EXPLOSION RISK! Alerts the operator that there is risk of
explosion.
207980 Revision F, October 2017 5