1. General information................................................................................................................................... 1
1.1. Contents:............................................................................................................................................1
1.2. Operating conditions and range:..................................................................................................... 1
1.3. Advantages of different modes:.......................................................................................................1
1.4. Kind reminder:................................................................................................................................... 2
2. Operations............................................................................................................................................4
2.1. Notice before using..............................................................................................................................4
2.2. Operation instructions.......................................................................................................................... 4
2.3. Daily maintenance and winterizing.......................................................................................................5
3. Technical specification......................................................................................................................... 6
1. Transportation......................................................................................................................................7
2. Installation and maintenance..............................................................................................................7
2.1. Notice before installation:..............................................................................................................7
2.2. Installation instruction....................................................................................................................... 8
2.3. Trial after installation.......................................................................................................................11
2.4. Maintenance and winterizing.........................................................................................................12
3. Trouble shooting for common faults................................................................................................12
4. Failure code........................................................................................................................................13
Appendix 1: Heating priority wiring diagram (Optional).....................................................................14
vivapool.pl
For users ………………………………………………………………………………. P.1-P.6
For installers and professionals ………………………………………………… P.7-P.15
vivapool.pl
vivapool.pl
vivapool.pl
vivapool.pl
vivapool.pl
For users

1. General information

1.1. Contents:

After unpacking, please check if you have all the following components.

1.2. Operating conditions and range:

Items Range
Operating range Air temp
-7~43
Temp. setting heating
18~35
The heat pump will have ideal performance in the operation range Air 15~25

1.3. Advantages of different modes:

The heat pump has two modes: Smart and Silence. They have different advantages under different conditions
1
vivapool.pl
vivapool.pl
Mode Recommendation Advantages
As standard Heating capacity: 25% to 100% capacity
Intelligent optimization Fast heating
Use at night Heating capacity: 25% to 80% capacity
Sound level: 3dB (A) lower than Smart mode.
vivapool.pl
For users
2
vivapool.pl
vivapool.pl
vivapool.pl
For users

1.4. Kind reminder:

This heat pump has Power-off memory function. When the power is recovered, the
heat pump will restart automatically.
1.4.1. The heat pump can only be used to heat the pool water. It can NEVER be used to heat other flammable or turbid liquid.
1.4.2. Don’t lift the water union when moving the heat pump since the titanium heat
exchanger inside the heat pump will be damaged.
1.4.3. Don’t put obstacles before the air inlet and outlet of the heat pump.
1.4.4. Don’t put anything into inlet or outlet, or the efficiency of the heat pump will be
reduced or even stopped.
1.4.5. Don’t use or store combustible gas or liquid such as thinners, paint and fuel to avoid
fire.
3
vivapool.pl
vivapool.pl
vivapool.pl
For users
1.4.6. If any abnormal circumstances occurred, e.g.: abnormal noises, smells, smokes and
leakage of electricity, switch off the main power immediately and contact your local dealer. Don’t try to repair the heat pump by yourselves.
1.4.7. The main power switch should be out of the reach of Children.
1.4.8. Please cut off the power in the lightning storm weather.
1.4.9. Please note that following codes are not failure.
Codes
No water flow
Anti-Freezing Reminder
Out of the operating range
Insufficient water flow or pump
blocked Power abnormal
4
vivapool.pl
vivapool.pl
vivapool.pl
For users

2. Operations

2.1. Notice before using

The user is advised to start the water pump before the heat pump, and turn off the
heat pump before the water pump for long life circle.
② Check firstly for any water leakage of piping connection, then power on, press the
ON/OFF button of the heat pump, and set suitable temperature.

2.2. Operation instructions

Symbol Designation Operation
Power ON/OFF Press to power on or off the heat pump
Mode Press to select Smart/Silence mode
Up/ Down Press to set desired water temperature
Note:
You may set the desire d water temperature from 18 to 35 .
The on the right shows the inlet water temperature. The on the left shows the
set temperature by pressing or button.
After you turn on the heat pump, the fan will start to run in 3 minutes. In another 30
seconds, the compressor will start to run.
During heating, the will be light.
5
vivapool.pl
vivapool.pl
vivapool.pl
For users
2.2.1. Mode selections
will be light as standard when you turn on the heat pump.
② Press the button to enter the Silence mode, the will be light.
Press the button again to exit and enter the SMART mode.
2.2.2. Compulsory defrosting
When the heat pump is heating and the compressor is working continuously for 10
minutes, press both “ ” and “ ” buttons for 5 seconds to start compulsory
defrosting. (Note: the interval between compulsory defrosting should be more than 30 minutes.)
② The heating light will be twinkling when heat pump is in compulsory or auto defrosting.
The running process and ending of compulsory defrosting are the same as auto-
defrosting.

2.3. Daily maintenance and winterizing

2.3.1. Daily Maintenance
Please don’t forget to cut off power supply of the heat pump
Please clean the evaporator with household detergents or clean water, NEVER use
gasoline, thinners or any similar fuel.
② Check bolts, cables and connections regularly.
2.3.2. Winterizing
In winter season when you don’t swim, please cut off power supply and drain water out of the heat pump. When using the heat pump under 2 , make sure there is always water flow.
6
vivapool.pl
vivapool.pl
Important:
Unscrew the water union of inlet pipe
vivapool.pl
to let the water flow out. When the water in machine freezes in winter season, the titanium heat exchanger may be damaged.
5
For users

3. Technical specification

Model IPH20 IPH25 IPH28 IPH35 IPH45 IPH55 IPH70 IPH70T IPH100T
Advised pool volume
(m3)
18-35 20-40 25-50 30-60 40-75 50-95 65-120 65-120 90-169
Working air temp ( ) -7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW) 8.1~2.0 10.0~2.5 11.5~2.8 13.5~3.4 17.5~4.4 21.5~5.4 28.2~7.1 27.8~7.0 36.5~9.2
Heating capacity (kW)
in silence mode
6.5~2.0 8.0~2.5 9.2~2.8 10.6~3.4 14.0~4.4 17.0~5.4 22.1~7.1 22.0~7.0 29.2~9.2
C.O.P 6.7~16.0 6.7~16.0 6.8~16.1 6.7~16.0 6.6~16.1 6.4~16.0 6.6~16.2 6.5~16.1 6.7~16.4
C.O.P in silence mode 7.8~16.0 7.8~16.0 7.9~16.1 7.8~16.0 7.6~16.1 7.5~16.0 7.7~16.2 7.6~16.1 7.8~16.4
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW) 5.6~1.4 6.6~1.7 7.5~1.9 9.5~2.3 11.5~2.8 14.5~3.4 18.3~4.6 18.2~4.5 24.2~6.2
Heating capacity (kW)
in silence mode
4.5~1.4 5.3~1.7 6.0~1.9 7.6~2.3 9.0~2.8 11.5~3.4 14.9~4.6 14.8~4.5 19.5~6.2
C.O.P 4.6~8.0 4.6~8.0 4.7~8.1 4.6~8.0 4.5~8.2 4.5~8.1 4.6~8.3 4.5~8.2 4.7~8.4
C.O.P in silence mode 5.4~8.0 5.4~8.0 5.5~8.1 5.4~8.0 5.4~8.2 5.1~8.1 5.4~8.3 5.3~8.2 5.5~8.4
Rated input power
(kW) at air 15
1.2~0.17 1.5~0.2 1.7~0.22 2.1~0.25 2.5~0.33 3.33~0.44 4.0~0.58 4.0~0.58 5.2~0.79
Rated input current(A)
at air 15
5.2~0.74 6.5~0.86 7.4~0.95 9.1~1.1 10.9~1.4 14.5~1.9 17.4~2.5 5.8~0.8 8.0~1.1
Max input current(A) 8.0 9.0 10.0 11.0 13.5 17.5 21.0 7.0 9.5
Power supply 230V/1 Ph/50Hz 400V/3 Ph/50Hz
Advised water flux
(m³/h)
2~4 3~4 4~6 5~7 6.5~8.5 8~10 10~12 10~12 12~18
Sound pressure 1m
dB(A)
38.5~47.239.3~48.039.5~48.242.8~52.144.2~52.944.7~53.8 48.6~55.5 48.6~55.5 49.6~55.8
Sound pressure 10m
dB(A)
18.5~27.219.3~28.019.5~28.222.8~32.124.2~32.924.7~33.8 28.6~35.5 28.6~35.5 29.6~35.8
Water pipe in-out
Spec (mm)
50
Net Dimension
LxWxH (mm)
844*308*648 894*308*648 954*308*648 954*308*648 954*388*648 954*388*755 1084*388*948 1084*388*948 1154×498×948
7
vivapool.pl
vivapool.pl
vivapool.pl
For users
Net Weight (kg) 45 49 50 52 63 68 90 93 117
1. The values indicated are valid under ideal conditions: Pool covered with an isothermal cover,
filtration system running at least 15 hours a day
2. Related parameters are subject to adjustment periodically for technical improvement without further
notice. For details please refer to nameplate.
8
vivapool.pl
vivapool.pl
vivapool.pl
For installers and professionals

1. Transportation

1.1. When storing or moving the heat pump, the heat pump should be at the upright
position.
1.2. When moving the heat pump, do not lift the water union since the titanium heat
exchanger inside the heat pump will be damaged.

2. Installation and maintenance

The heat pump must be installed by a professional team. The users are not qualified to
install by themselves, otherwise the heat pump might be damaged and risky for users’ safety.
2.1. Notice before installation
2.1.1. The inlet and outlet water unions can’t bear the weight of soft pipes. The heat pump
must be connected with hard pipes!
2.1.2.In order to guarantee the heating efficiency, the water pipe length should be ≤10m
between the pool and the heat pump.
9
vivapool.pl
vivapool.pl
vivapool.pl
For installers and professionals

2.2. Installation instruction

2.2.1. Location and size
The heat pump should be installed in a place with good ventilation
10
vivapool.pl
* Minimum distance
filter water processor water switch
vivapool.pl
vivapool.pl
Loading...
+ 29 hidden pages