INSTALLATION & USER MANUAL
Thank you for choosing Rapid by Fairland Inverter-Plus heat pump.
EN-CZ
Summary
For installers and professionals
1. General information: .............................................................................................................................. - 3 -
1.1. Contents: .............................................................................................................................................. - 3 -
1.2. Operating conditions and range:....................................................................................................... - 3 -
1.3. Advantages of different modes: ........................................................................................................ - 3 -
1.4. Kind reminder: ..................................................................................................................................... - 4 -
2. Operations ............................................................................................................................................... - 6 -
2.1. Notice before using ............................................................................................................................. - 6 -
2.2. Operation instructions ........................................................................................................................ - 6 -
2.3. Daily maintenance and winterizing ................................................................................................... - 8 -
3. Technical specification ........................................................................................................................... - 9 -
1. Transportation ....................................................................................................................................... - 10 -
2. Installation and maintenance .............................................................................................................. - 10 -
2.1. Notice before installation: .............................................................................................................. - 10 -
2.2. Installation instruction ....................................................................................................................... - 11 -
2.3. Trial after installation ...................................................................................................................... - 14 -
2.4. Maintenance and winterizing ........................................................................................................ - 15 -
3 . Trouble shooting for common faults ................................................................................................. - 15 -
4. Failure code ........................................................................................................................................... - 15 -
APPENDIX 1: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) ................................ - 16 -
APPENDIX 2: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) ................................ - 17 -
APPENDIX 3: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) ................................ - 18 -
PLEASE READ IT CAREFULLY AND KEEP IT FOR SUBSEQUENT USE
This manual provides you necessary information for optimal use and maintenance
For users
Warning:
a. Please read the following tips before installation, use and maintenance.
b. Installation, removal and maintenance must be carried out by Professional personional
in accordance with the instructions.
c. Gas leakage test must be done before and after installation.
1. Use
a. It must be installed or removed by professionals, and it is forbidden to dismantle and
refit without permission.
b. Don’t put obstacles before the air inlet and outlet of the heat pump.
2. Installation
a. This product must be kept away from any source of fire.
b. The installation can’t be in a closed environment or indoors, and must be kept well
ventilated.
c.
d. Vacuum completely before welding, field welding is not allowed, welding can only be
performed by professional personnel in professional maintenance center.
- 1 -
For users
e. Installation must be stopped if any gas leakage, and the unit must be returned to
professional maintenance center.
3. Transportation & Storage
a. Sealing is not allowed during transportation
b. Transporting goods at a constant speed is needed to avoid sudden acceleration or
sudden braking, so as to reduce the collision of goods.
c. The unit must be far away from any source of fire.
d. Storage place must be bright, wide, open and good ventilation, ventilation equipment is
required.
4. Maintenance Notice
a. If maintenance or scrap is required, contact an authorized service center nearby
b. Qualification requirement
All operators who dispose gas must be qualified by valid certification which issued by
professional agency.
c. Please strictly comply with the requirement from manufacturer when maintenance or
filling gas. please refer to the technical service manual.
- 2 -
1. General information:
1.1. Contents:
After unpacking, please check if you have all the following components.
1.2. Operating conditions and range:
For users
ITEMS RANGE
Operating range Air temp
heating
-7℃~43℃
18℃-35℃
Temp. setting
cooling
12℃-30℃
The heat pump will have ideal performance in the operation range Air 15
℃~25℃
1.3. Advantages of different modes:
The heat pump has two modes: Smart and Silence. They have different advantages under
different conditions
MODE RECOMMENDATION ADVANTAGES
Heating capacity: 20% to 100% capacity
Smart mode
As standard
Intelligent optimization
Fast heating
Silence mode
Heating capacity: 20% to 80% capacity
Use at night
Sound level: 3dB (A) lower than Smart mode.
- 3 -
For users
1.4. Kind reminder:
This heat pump has Power-off memory function. When the power is recovered, the heat
pump will restart automatically.
1.4.1. The heat pump can only be used to heat the pool water. It can NEVER be used to
heat other flammable or turbid liquid.
1.4.2. Don’t lift the water union when moving the heat pump since the titanium heat
exchanger inside the heat pump will be damaged.
1.4.3. Don’t put obstacles before the air inlet and outlet of the heat pump.
1.4.4. Don’t put anything into inlet or outlet, or the efficiency of the heat pump will be reduced
or even stopped.
1.4.5. Don’t use or store combustible gas or liquid such as thinners, paint and fuel to avoid
fire.
- 4 -