www.fairchildsemi.com
KA78MXX
3-Term inal 0.5A Positive Voltage Regulator
Features
• Output Current up to 0.5A
• Output Voltages of 5, 6, 8, 12, 15, 18, 24V
• Thermal Overload Protection
• Short Circuit Protection
• Output Transistor Safe Operat ing Area (SOA) Protection
Internal Block Diagram
Description
The KA78MXX series of three terminal positive regulators
are available in the TO-220/D-PAK package with several
fixed output voltages making it useful in a wide range of
applications.
TO-220
1
D-PAK
1
1. Input 2. GND 3. Output
GND
GND
INPUT
1
CURRENT
GENERATOR
STARTING
CIRCUIT
©2002 Fairchild Semiconductor Corporation
REFERENCE
VOLTAGE
ERROR
AMPLIFIER
SOA
PROTECTION
THERMAL
PROTECTION
SERIES
PASS
ELEMENT
OUTPUT
3
R1
R2
GND
2
Rev. 1.0.5
KA78MXX
Absolute Maximum Ratings
Parameter Symbol Value Unit
Input Voltage (for V
(for V
= 24V)
O
Thermal Resistance Junction-Cases (Note1)
TO-220 (Tc = +25°C)
= 5V to 18V)
O
R
V
I
V
I
θ JC
35
40
2.5 °C/W
Thermal Resistance Junction-Air (Note1,2)
TO-220 (Ta = +25°C)
D-PAK (Ta = +25°C)
Operating Junction Temperature Range T
Storage Temperature Range T
Note:
1. Thermal resistance test board
Size: 76.2mm * 114.3mm * 1.6mm(1S0P)
JEDEC standard: JESD51 -3, JESD51-7
2. Assume no ambient airflow
R
θ JA
OPR
STG
66
° C/W
92
0 ~ +150 °C
-65 ~ +150 °C
Electrical Characteristics (KA78M05/KA78M05R)
(Refer to the test circuits, 0
< TJ < +125°C, I O=350mA, VI=10V, unless otherwise specified, CI =0.33 µ F, CO=0.1 µ F)
V
V
Parameter Symbol Conditions Min. Typ. Max. Unit
TJ =+25° C4 . 8 5 5 . 2
Output Voltage V
Line Regulation (Note3) ∆V
Load Regulation (Note3) ∆V
Quiescent Current I
O
O
= 5 to 350mA
I
O
V
= 7 to 20V
I
IO = 200mA
T
=+25°C
J
4.75 5 5.25
V
= 7 to 25V - - 100
I
= 8 to 25V - - 50
V
I
IO = 5mA to 0.5A, TJ = +25°C - - 100
O
Q
= 5mA to 200mA, TJ =+25°C- - 5 0
I
O
TJ = +25°C- 4 . 0 6 . 0 m A
V
mV
mV
IO = 5mA to 350mA - - 0.5
Quiescent Current Change ∆I
Q
Output Voltage Drift ∆V/∆T
Output Noise Voltage V
N
Ripple Rejection RR
Dropout Voltage V
Short Circuit Current I
Peak Current I
D
SC
PK
= 200mA
I
O
V
= 8 to 25V
I
= 5mA
I
O
T
= 0 to +125°C
J
--0 . 8
-- 0 . 5-m V /°C
f = 10Hz to 100kHz - 40 f = 120Hz, I
V
= 8 to 18V, TJ = +25°C
I
= 300mA
O
-8 0- d B
TJ = +25° C, IO = 500mA - 2 - V
TJ = +25° C, VI = 35V - 300 - mA
TJ = +25°C - 700 - mA
mA
µ
V/Vo
Note:
3. Load and line regulation are specified at constant junction temperature. Change in V
into account separately. Pulse testing with low duty is used.
2
due to heating effects must be taken
o
KA78MXX
Electrical Characteristics (KA78M06/KA78M06R)
(Continued)
(Refer to the test circuits, 0 < TJ < +125°C, I O=350mA, VI=11V, unless otherwise specified, CI =0.33µ F, CO=0.1µ F)
Parameter Symbol Conditions Min. Typ. Max. Unit
TJ = +25°C 5.75 6 6.25
Output Voltage V
Line Regulation (Note1) ∆V
Load Regulation (Note1) ∆V
Quiescent Current I
O
O
= 5 to 350mA
I
O
V
= 8 to 21V
I
IO = 200mA
T
=+25°C
J
5.7 6 6.3
V
= 8 to 25V - - 100
I
= 9 to 25V - - 50
V
I
IO = 5mA to 0.5A, TJ =+25° C - - 120
O
Q
= 5mA to 200mA, TJ =+25°C- - 6 0
I
O
TJ =+25° C- 4 . 0 6 . 0 m A
V
mV
mV
IO = 5mA to 350mA - - 0.5
Quiescent Current Change ∆I
Q
Output Voltage Drift ∆V/∆T
Output Noise Voltage V
N
Ripple Rejection RR
Dropout Voltage V
Short Circuit Current I
Peak Current I
D
SC
PK
= 200mA
I
O
V
= 9 to 25V
I
I
= 5mA
O
T
= 0 to +125°C
J
--0 . 8
-- 0 . 5-m V /°C
f = 10Hz to 100kHz - 45 f = 120Hz, I
V
= 9 to 19V, TJ = +25°C
I
= 300mA
O
-8 0- d B
TJ =+25° C, IO = 500mA - 2 - V
TJ= +25° C, VI = 35V - 300 - mA
TJ =+25°C - 700 - mA
mA
µ
V/Vo
Note:
1. Load and line regulation are specified at constant, junction temperature. Change in V
into account separately. Pulse testing with low duty is used.
due to heating effects must be taken
o
3
KA78MXX
Electrical Characteristics (KA78M08/KA78M08R)
(Continued)
(Refer to the test circuits, 0 < TJ < +125°C, I O=350mA, VI=14V, unless otherwise specified, CI =0.33µ F, CO=0.1µ F)
Parameter Symbol Conditions Min. Typ. Max. Unit
TJ = +25°C 7.7 8 8.3
Output Voltage V
Line Regulation (Note1) ∆V
Load Regulation (Note1) ∆V
Quiescent Current I
O
O
= 5 to 350mA
I
O
V
= 10.5 to 23V
I
IO = 200mA
T
=+25°C
J
7.6 8 8.4
V
= 10.5 to 25V - - 100
I
= 11 to 25V - - 50
V
I
IO = 5mA to 0.5A, TJ = +25°C - - 160
O
Q
= 5mA to 200mA, TJ = +25°C- - 8 0
I
O
TJ = +25°C- 4 . 0 6 . 0 m A
V
mV
mV
IO = 5mA to 350mA - - 0.5
Quiescent Current Change ∆I
Output Voltage Drift RR
Output Noise Voltage V
Ripple Rejection RR
Dropout Voltage V
Short Circuit Current I
Peak Current I
SC
PK
Q
N
D
= 200mA
I
O
V
= 10.5 to 25V
I
I
= 5mA
O
T
= 0 to +125°C
J
--0 . 8
-- 0 . 5-m V /°C
f = 10Hz to 100kHz - 52 f = 120Hz, I
V
= 11.5 to 21.5V, TJ = +25°C
I
= 300mA
O
-8 0-d B
TJ =+25° C, IO = 500mA - 2 - V
TJ =+25° C, VI= 35V - 300 - mA
TJ =+25°C - 700 - mA
mA
µ
V/Vo
Note:
1. Load and line regulation are specified at constant, junction temperature. Change in V
into account separately. Pulse testing with low duty is used.
due to heating effects must be taken
o
4
KA78MXX
Electrical Characteristics (KA78M12/KA78M12R)
(Continued)
(Refer to the test circuits, 0 < TJ < +125°C, I O=350mA, VI=19V, unless otherwise specified, CI =0.33µ F, CO=0.1µ F)
Parameter Symbol Conditions Min. Typ. Max. Unit
TJ = +25°C 11.5 12 12.5
Output Voltage V
Line Regulation (Note1) ∆V
Load Regulation (Note1) ∆V
Quiescent Current I
O
O
= 5 to 350mA
I
O
V
= 14.5 to 27V
I
IO = 200mA
T
= +25°C
J
11.4 12 12.6
V
= 14.5 to 30V - - 100
I
= 16 to 30V - - 50
V
I
IO = 5mA to 0.5A, TJ = +25°C - - 240
O
Q
= 5mA to 200mA, TJ =+25°C - - 120
I
O
TJ=+25° C- 4 . 1 6 . 0 m A
V
mV
mV
IO = 5mA to 350mA - - 0.5
Quiescent Current Change ∆I
Q
Output Voltage Drift ∆V/∆T
Output Noise Voltage V
N
Ripple Rejection RR
Dropout Voltage V
Short Circuit Current I
Peak Current I
D
SC
PK
= 200mA
I
O
V
= 14.5 to 30V
I
I
= 5mA
O
T
= 0 to +125°C
J
--0 . 8
-- 0 . 5-m V /°C
f = 10Hz to 100kHz - 75 f = 120Hz, I
V
= 15 to 25V, TJ = +25°C
I
= 300mA
O
-8 0-d B
TJ =+25° C, IO = 500mA - 2 - V
TJ= +25° C, VI = 35V - 300 - mA
TJ = +25°C - 700 - mA
mA
µ
V/Vo
Note:
1. Load and line regulation are specified at constant, junction temperature. Change in V
into account separately. Pulse testing with low duty is used.
due to heating effects must be taken
o
5