REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015
1 RECEIVING AND INSPECTING THE EQUIPMENT
Up on receiving your new Fagor Refrigerator, check the package and the machine for any
damages that may have occurred during transportation. Visually inspect the exterior of the
package. I f damaged, open and inspect the contents with the carrier. Any damage should be
noted and reported on the delivering carrier’s receipt.
In the event that the exterior is not damaged, yet up on opening, there is concealed damage to
the equipment notify, the carrier immediately. Notification should be made verbally as well as
in written form. Request an inspection by the shipping company of the damaged equipment.
Retain all crating material until inspection has been made. Contact the dealer through which
you purchased the unit.
Check the compressor compartment thousing and visually inspect the refrigeration package.
Be sure lines are secure and base is still intact.
A NOTE FROM OUR QUALITY CONTROL MANAGER
CONGRATULATIONS ON YOUR NEW PURCHASE. WE WOULD LIKE TO WELCOME
YOU TO THE FAGOR TEAM. THE UNIT IN FRONT OF YOU IS A GREAT PIECE OF
EQUIPMENT THAT WILL BECOME ONE OF YOUR MOST RELAIBLE TOOLS IN YOUR
DAILY OPERATIONS FOR YEARS TO COME!
PRIOR TO SHIPPING YOUR UNIT, OUR TRAINED SERVICE TECHNICIANS TESTED
YOUR UNIT FOR A PERIOD OF 12 HOURS. THIS PERFORMANCE TEST WAS
RECORDED AND A COPY OF THE RESULTS IS INCLUDED WITH THIS SERVICE
MANUAL. DURING THIS TEST, OUR HIGHLY QUALIFIED PERSONNEL INSPECTED
YOUR MACHINE FOR LEAKS, LOSE COMPONENTS,AND IMPROPER NOISE LEVELS.
WE ALSO TESTED THE COOLING PERFORMANCE IN AN EFFORT TO GIVE YOU THE
BEST AND MOST RELAIBLE UNIT POSSIBLE.
PAGE 3
www.Fagorcommercial.com
REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015
REACH IN REFRIGERATORS AND FREEZERS, GENERAL SPECS
Model
Capac.
(Cu.Ft.)
# of
Shvls
BTU'S/Hr
Charge
Onz.
Ref.
Ship
Weight
QR-1
23 3 1666
11.3
R-134a
295
QR-2
49 6 2104
13.4
R-134a
475
QF-1
23 3 2493
16.6
R-404A
295
QF-2
49 6 3644
21.5
R-404A
475
QR-1G
23 3 1666
11.3
R-134a
295
QR-2G
49 6 2104
13.4
R-134a
475
QVR-1
21 3 1666
11.3
R-134a
295
QVR-2
45 6 2104
13.4
R-134a
475
QVF-1
21 3 2493
16.6
R-404A
295
QVF-2
45 6 3644
21.5
R-404A
475
QVR-1G
21 3 1666
11.3
R-134a
295
QVR-2G
45 6 2104
13.4
R-134a
475
QVR-3
72 9 -
22.2
R-404A
-
QVF-3
72 9 -
16.6
R-404A
-
2 SPECIFICATIONS
PAGE 4
www.Fagorcommercial.com
REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015
REACH IN REFRIGERATORS AND FREEZERS, ELECTRICAL SPECS
Model
Max.
Amps
HP
Voltage
NEMA
Plug
Breaker
Size*
Wire gauge recommended for 2% voltage drop in supply circuits **
40 ft ***
60 ft
80 ft
100 ft
120 ft
140 ft
QR-1
5.6
3.1
1/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
QR-2
6.9
3.5
1/3
3/8
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
10 AWG
12 AWG
QF-1
8.5
4.5
3/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
QF-2
12.9
6.5 1
115
220
5-15P
2P+TT
20 amp
10 amp
12 AWG
14 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
6 AWG
12 AWG
QR-1G
6
3.4
1/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
QR-2G
7.3
3.9
1/3
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
QVR-1
5.6
3.1
1/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
10 AWG
12 AWG
QVR-2
6.9
3.5
1/3
3/8
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
10 AWG
12 AWG
QVF-1
8.5
4.5
3/4
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
QVF-2
12.9
6.5
1
115
220
5-15P
2P+TT
20 amp
10 amp
12 AWG
14 AWG
10 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
6 AWG
12 AWG
QVR-
1G
5.9
1/4
115
5-15P
15 amp
14 AWG
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
QVR-
2G
7.3
3.9
1/3
3/8
115
220
5-15P
2P+TT
15 amp
10 amp
14 AWG
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
10 AWG
12 AWG
10 AWG
12 AWG
8 AWG
12 AWG
QVR-3
11.5
3/4
115
5-15P
15 amp
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
8 AWG
QVF-3
16.0
3/4
115
5-15P
15 amp
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
8 AWG
Note:
*Breaker sizes are recommended to protect the equipment by overload; this
breaker only must be dedicated for the equipment.
**If the equipment is installed faraway of the circuit breaker, these are the
wire gauge recommend to connect the appliance; if the distance is higher that
the chart values, please contact an electrician.
***Distance in feet from the breaker or the power supply to the appliance.
PAGE 5
www.Fagorcommercial.com
REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015
3 INSTALLATION
3.1 UN CRATING
Remove the outer packaging. Cut the 4 clamps that hold the refrigerator to the skid. Lift the unit off
the skid.
If machine was laid down during this operation, remember to leave the cabinet up
right for 24 hours before connecting to power source.
3.2 LOCATION
Units represented in this manual are intended for indoor use only. Be sure the location chosen has a
floor strong enough to support the total weight of the unit and its contents. For the most efficient
operation, be sure to provide at least three (3) inches between sides, back and top of the unit.
THE MACHINES NEEDS TO BE INSTALLED 2 FEET AWAY FROM ANY HEAT SOURCES.
The unit should not be installed under ambient temperatures higher than 100 °F.
If the relative humidity is higher than 60 %, the door frames may sweat water. This is not a
malfunctioning of the unit.
WARNING
The following actions will void your warranty:
-Modification of power cord.
-Connecting the unit to any extension cord.
-Neglecting to install the castors or optional legs.
Inside cabinet:
The first cleaning must happen when you unpack the unit and before it is turned ON. For this, you
have to clean the unit with warm water and mild detergent. When it is cleaned and dry, proceed to
install accessories and plug your unit into a dedicated outlet. WAIT 24 HOURS BEFORE PLACING
PRODUCT IN THE UNIT. This will guarantee that it is working properly. Consequential damages are
not covered under warranty.
PAGE 6
www.Fagorcommercial.com
REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015
Model
Electrical
Refrigerant Type
SERIAL NUMBER FOR
THE EQUIPMENT
(8 digits and ends in
“M”)
Outside cabinet:
Be sure that the unit has access to ample air to breathe. Avoid hot corners and locations near stoves
and ovens. It is recommended the unit be installed no closer than 3” from any wall. The place where
the refrigerator is placed must be open and clean. This will reduce the amount of debris and dirt on
the condenser fan and coil.
3.3 DATA PLATE
The data plate is located inside the cabinet, near the top front, left corner. Under no circumstances
should the data plate be removed from the unit. The data plate is essential to identify the particular
features of your machine and i t is of great benefit to installers, operators, and maintenance
personnel. It is recommended that, in the event the data plate is removed, you copy down the
essential information in this manual for reference before installation. Removal of data plate will void
the warranty.
3.4 INSTALLATION OF CASTORS OR OPTIONAL LEGS
To obtain maximum strength and stability of the unit, be sure that castors are secure and unit is level.
Inside the unit you will find a Castor kit which includes: four castor wheels, leveling shims, and
assembly tool.
Installation of castors:
Cut the 4 straps that hold the refrigerator to the pallet.
PAGE 7
www.Fagorcommercial.com
REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015
Slide out unit until castor holes are exposed. CASTORS WITH BRAKES MUST BE INSTALLED IN THE
FRONT OF THE UNIT
Carefully, lift the unit high enough to install the casters.
Repeat the same operation to install the remaining castors.
CAUTION! NEVER LAY MACHINE ON ITS BACK! IF NEEDED, LEAVE THE CABINET UP RIGHT FOR 24
HOURS BEFORE CONNECTING TO POWER SOURCE. TO AVOID DAMAGE TO LOWER FRAME, SLOWLY
RAISE UNIT TO UP RIGHT POSITION
FAILURE TO MEET THIS REQUIREMENT CAN CAUSE COMPRESSOR FAILURE AND UNIT DAMAGE. THIS
WILL NOT BE COVERED UNDER WARRANTY!
For leveling, insert shims between the castor and the frame rail. Install the desired number of shims.
Make sure the slot of the shim is in contact with the threaded stem of the castor.FIG.2
If more than one shim is used, turn the slot of the shim approximately 90 angles. If shims are installed
in line, they may slip out.
Turn the bearing race clockwise to tighten and secure the castor. Use provided tool to secure all
castors properly.FIG.3
FIG.1 FIG.2 FIG.3
Optional legs are hand-tightened. Thread leg into cabinet bottom frame rail. The end of the leg is
adjustable for easy leveling.
Caution! To avoid damage to lower rail assembly, slowly raise unit to upright position
Caution! When lifting unit remember to leave the cabinet up right for 24 hours before plugging into
power source. Failure to meet this requirement can cause compressor failure and unit damage.
PAGE 8
www.Fagorcommercial.com
REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015
3.5 LEVELING
Set unit in its final location. A level cabinet looks better and will perform better. Effective condensate
removal and door operation will be effected by leveling. Machine must be leveled front to back and
side to side with a level tool. Castors k i t w i l l include shims for leveling. Insert the shim between the
castor and the frame rail. (See installation of castors). Lock front castors so cabinet does not move.
Ensure drain hose is inside drain pan.
3.6 ELECTRICAL CONNECTIONS
Refer to the amperage data in this manual, or on data plate, and your local code or the National
Electrical Code to be sure unit is connected to the proper power source. Verify correct incoming
voltage according to the Data Plate information.
Do not, under any circumstances, cut or remove the ground prong from the power cord. Fagor units
must be properly grounded.
NEVER USE AN EXTENSION CORD! Fagor will not warranty any unit that has been
connected to an extension cord.
Fagor equipment must be grounded and connected in accordance with NEC Article 422Appliances.
DANGER:
Power must be turned off and disconnected from the power source whenever performing
maintenance, repair or cleaning the condensing unit.
If machine is still running when power is off, disconnect power at the circuit breaker before
unplugging the machine.
WARNING:
Machine and compressor warranties are void if failure is due to improper electrical
PAGE 9