Installation Instructions
®
6214/6214DS Electric Strike
Single Door Mortise or Cylindrical Application
931233-00
89/336/EEC
Notes: Deadbolt will not function with this strike.
1. For lock or device preparation, see their directions.
2. Prepare frame for strike (see other side).
3. Wire strike (Figure 1). (Switches on 6214DS only.)
Wiring
for DC
supply
Wiring
for AC
supply
Check with factory for retrofit applications.
SOLENOID POWER REQUIREMENTS
Yellow solenoid wires = 12 VDC, 0.57 A
Black solenoid wires = 24 VDC, 0.29 A
(also shown on strike label)
NOTE
!
DC input is
{
nonpolarized.
12 VAC SO-12 12 VDC
or
24 VAC SO-24 24 VDC
12 VDC
or
24 VDC
{
Use crimp
connectors to
splice field wiring
to P1 leads
P1 J1A P1A
P1
J1
SO-12 or SO-24
Figure 1
Solenoid
4. Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks.
Fail safe (FS) lip locks. Figure 1 shows status of switches.
5. Install strike with two #12-24 screws. Make sure clearance
between latch bolt and strike lip is 1/32” (Figure 2). If not,
uninstall strike, adjust (Figure 3), and reinstall.
6. If latch bolt does not extend far enough to actuate tripper,
install extension (Figure 4). (Tripper on 6214DS only.)
7. Test door: With strike unlocked, door opens
with latch bolt extended. When door closes,
latch bolt rides over strike lip.
P2
J2
S1
S2
Fail safe (FS)J2Fail secure (FSE)
depressed, strike lip closed and locked
(switches and tripper on 6214DS only)
1
2
3
4
5
6
J2
Switches shown with tripper
Use crimp connectors to
splice field wiring to P2
leads; insulate unused leads
S1
S2
1
2
3
4
5
6
P2
Standard: 5 A, 30 VDC
Gold: 0.25 A, 30 VDC
Red (C)
Blue
Yellow
White (C)
Gray
Violet
SWITCH RATINGS
(monitors
}
(monitors
}
strike lip)
S1
tripper)
S2
Strike lip
Latch bolt
1/32”
Top view;
faceplate not
shown for clarity
Figure 2
931233_00(5) Copyright © 2004 Ingersoll-Rand. All rights reserved.
A
B
Figure 3
To adjust strike,
loosen screws A, B,
and C and move
backbox sideways
as necessary
D
For more
adjustment, move
screw A to hole D
C
Extension
Tripper
Figure 4
C lock and strike
L
1-3/8”
2”
2-5/8”
LHR shown
RHR opposite
#16 drill and #12-24 tap
2” minimum
clearance
Strike
backbox
assembly
9”
5/16”
2 places
8-3/8”
Reinforce for strike
attachment as required
Frame Preparation for Strike
1-7/8” minimum
clearance
3-3/4”
C strike and
L
latch bolt
Suggested
cutout
11/32” maximum
9”
4-1/2”
C lock and strike
L
11/16”
1-3/8”
1-3/8”
4-3/16”
1-5/8”
8-3/8”
1-7/8”
3-3/4”
2”
C strike
latch bolt
6”
L
and
12”
minimum
clearance
931233_00(5)
5/32”
Strike Dimensions and Required Clearances