Installation Instructions
®
931222-00
6212WF/6212WFDS Electric Strike
Single Door Wood Frame Mortise or Cylindrical Application
89/336/EEC
Notes: Deadbolt will not function with this strike.
1. For lock or device preparation, see their directions.
2. Prepare frame for strike (see other side).
3. Wire strike (Figure 1). (Switches on 6212WFDS only.)
Wiring
for DC
supply
Wiring
for AC
supply
Check with factory for retrofit applications.
SOLENOID POWER REQUIREMENTS
Yellow solenoid wires = 12 VDC, 0.57 A
Black solenoid wires = 24 VDC, 0.29 A
(also shown on strike label)
NOTE
!
DC input is
{
nonpolarized.
12 VAC SO-12 12 VDC
or
24 VAC SO-24 24 VDC
12 VDC
or
24 VDC
{
Use crimp
connectors to
splice field wiring
to P1 leads
P1 J1A P1A
P1
J1
SO-12 or SO-24
Figure 1
4. Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks.
Fail safe (FS) lip locks. Figure 1 shows status of switches.
5. Install strike with two #12-24 screws. Make sure clearance
between latch bolt and strike lip is 1/32” (Figure 2). If not,
uninstall strike, adjust (Figure 3), and reinstall.
6. If latch bolt does not extend far enough to actuate tripper,
install extension (Figure 4). (Tripper on 6212WFDS only.)
7. Test door: With strike unlocked, door opens with latch bolt
extended. When door closes, latch bolt rides over strike lip.
P2
Solenoid
J2
S1
S2
Fail safe (FS)J2Fail secure (FSE)
depressed, strike lip closed and locked
(switches and tripper on 6212WFDS only)
1
2
3
4
5
6
J2
Switches shown with tripper
Use crimp connectors to
splice field wiring to P2
leads; insulate unused leads
S1
S2
1
2
3
4
5
6
Red (C)
Blue
Yellow
White (C)
Gray
Violet
P2
SWITCH RATINGS
Standard: 5 A, 30 VDC
Gold: 0.25 A, 30 VDC
}
}
S1
(monitors
tripper)
S2
(monitors
strike lip)
Strike lip
A
Latch bolt
1/32”
Top view;
faceplate not
shown for clarity
Figure 2
931222_00(6) Copyright © 2004 Ingersoll-Rand. All rights reserved.
Figure 3
B
Extension
Tripper
To adjust strike,
loosen screws A, B,
and C and move
backbox sideways
as necessary
Figure 4
C
C lock and strike
L
6-3/8”
5-5/8”
LHR shown
RHR opposite
Door Preparation for Strike
1” dia. minimum
clearance
2-3/8” minimum
clearance
C strike
L
1-1/4”
3/4”
3-3/8”
Pilot drill for
#12 wood screws
1-15/32”
5/8”
6-3/8”
3-3/16”
1-1/4”
2-3/8” minimum
1-7/16” minimum
clearance
5/8”
1-1/8”
2-13/16”
5-5/8”
clearance
C strike
L
6” long lead wires; 1/2” dia.
minimum wiring access
1-13/32”
1-11/16”
3-11/16”
3-3/8”
3-9/16”
931222_00(6)
1/8”
1-15/32”
Strike Dimensions and Required Clearances
Minimum
clearance