6211/6211DS Electric Strike
Single Door Mortise or Cylindrical Application
931227-00
89/336/EEC
Notes: Deadbolt will not function with this strike.
1. For lock or device preparation, see their directions.
2. Prepare frame for strike (see other side).
3. Wire strike (Figure 1). (Switches on 6211DS only.)
Wiring for DC
supply
Wiring for AC
supply
Check with factory for retrofit applications.
SOLENOID POWER REQUIREMENTS
Yellow solenoid wires: 12 VDC, 0.57 A
Black solenoid wires: 24 VDC, 0.29 A
(also shown on strike label)
NOTE
!
DC input is
{
nonpolarized
12 VAC SO-12 12 VDC or 24 VAC SO-24 24 VDC
12 VDC
or
24 VDC
{
Use crimp
connectors to
splice field wiring
to P1 leads
P1 J1A P1A
P1
J1
Solenoid
SO-12 or SO-24
5. Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks.
Fail safe (FS) lip locks. Figure 1 shows status of switches.
6. Install strike with two #12-24 screws. Make sure clearance between latch bolt and strike lip is 1/32” (Figure 3). If not, uninstall strike, adjust (Figure 4), and reinstall.
7. If latch bolt does not extend far enough to actuate tripper,
install extension (Figure 5). (Tripper on 6211DS only.)
8. Test door: With strike unlocked, door opens with latch bolt
extended. When door closes, latch bolt rides over strike lip.
Use crimp connectors to splice field wiring to P2 leads; insulate unused leads
S1
S2
1 2 3 4 5 6
P2
SWITCH RATINGS
Standard: 5 A, 30 VDC
Gold: 0.25 A, 30 VDC
Red (C) Blue Yellow White (C) Gray Violet
(monitors
}
(monitors
}
strike lip)
Figure 1
J2 P2
S1
S2
Fail safe (FS)J2Fail secure (FSE)
depressed, strike lip closed and locked (switches and tripper on 6211DS only)
1 2 3 4 5 6
J2
Switches hown with tripper
S1
tripper)
S2
Latch bolt
Fit hook on insert
into notch on
faceplate
Alternate insert
position
Figure 2
931227_00(8) Copyright © 2004 Ingersoll-Rand. All rights reserved.
Strike lip
1/32”
Top view;
faceplate not
shown for clarity
Figure 3
To adjust strike, loosen screws A, B, and C and move backbox sideways as necessary
For more adjustment, move screw A to hole D
A
Figure 4
D
Extension
Tripper
B
C
Figure 5
4-7/8”
4-1/8”
3/8”
LHR shown
RHR opposite
C lock and strike
L
5/8”
Reinforce for
strike attachment
as required
1-1/4”
#16 drill and
#12-24 tap
2 places
1-15/32”
3/4”
3-3/8”
C strike
L
Suggested cutout
11/32” maximum
2” minimum
clearance
Strike
backbox
assembly
1-1/4”
4-7/8”
2-7/16”
Frame Preparation for Strike
1-21/32” minimum clearance
C lock and strike
L
5/8”
1-1/8”
2-1/16”
4-1/8”
C strike
L
3-3/8”
1-11/16”
931227_00(8)
1-1/4”
1/8”
Strike Dimensions and Required Clearances
12” minimum
clearance
6”