Factory Direct Hardware 1601T9006 User Manual

Electronic Activated Flush Valve 1600T and 1601T Series
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.
DSP-1600T6 Rev. B
(1) When used for TOP Inlet Urinal Fixture - Exposed Tubing, Flanges, Elbow, etc. SUPPLIED by Others
Refer to www.specselect.com for individual models. Note: Use this page front and back, with specification drawing page referenced above, as product submittal sheets.
000
Model Specified:
Approval: Date:
Specification: (example)
Battery (4 ‘C’ cell) or Hardwire (24 VAC)
infrared electronic activated concealed flushvalve system
• Stainless steel cover with integral sensor utilizing H
2
OPTICS
technology and S/S vandal resistant mounting screws
• Metal mounting box or frame, power function light, field selectable sensor range
• Preset blocking time, built-in activation delay
• Electronic manual override
• Solenoid operation valve
and... with... (add for fixture type required)
with... (add control/sensor box required) with... (transformer – specify separately – See Back Page)
FIXTURE TYPE
NOT APPLICABLE
CONTROL/SENSOR BOX
222
111
333
555
777
999
444
666
888
TOILET - Back Inlet
- Wallhung
- 1-1/2" Spud
TOILET - Back Inlet
- Free Standing
- 1-1/2" Spud
TOILET - Top Inlet
- Free Standing or Wallhung
- 1-1/2" Spud
For RECESSED MOUNTING Components ASSEMBLED w/Flushvalve in 12" Frame, w/Integral Sensor in 14" S/S Cover. SEE Specification Drawing #17
For RECESSED MOUNTING Components ASSEMBLED w/Flushvalve in 12 x 18" Frame, w/Integral Sensor in 14 x 20" S/S Cover. SEE Specification Drawing #17
URINAL - Back Inlet (1)
- 3/4" Spud
- Syphon Jet Type
For RECESSED MOUNTING Components ASSEMBLED w/Flushvalve, 4" Box, w/Integral Sensor in S/S Cover. SEE Specification Drawing #17
✔✔✔
DESCRIPTION PRODUCT NO.
Hardwire 1600T 6 0 RI Hardwire 1600T 6 0 TR Battery 1601T 6 0 RI Battery 1601T 6 0 TR Hardwire with Battery Backup 1600T 6 0 RI
Hardwire with Battery Backup 1600T 6 0 TR
Note: Rough-in and Trim Ordered Separately.
-BB Required on “TR” Only.
1600T6104RI and 1600T6104TR
TECK
®
COMMERCIAL
-BB
Electronic Activated Flushvalve
1600T and 1601T Series
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.
Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.
DSP–1600T6 Rev. B
Refer to www.specselect.com for individual models. Product supplied as shown by solid lines. All items shown by dotted lines supplied by others.
Note: Measurements may vary ± 6mm (0.25'')
1600T ELECTRONIC FLUSH VALVE OPTIONAL ACCESSORIES:
Approvals:
CSA certified
ADA Compliant and meets Handicapped Accessibility Standard ASME A117.1 of less than 5 lbs. handle operating force.
IAPMO listed
Complies to ASSE Standard 1037
(Contact Delta Representative for State and/or
Local Approvals.)
W.C. OPERATION:
• 8 second blocking time.
• 4 second activation delay.
• Adjustable flush volume using adjustment screw on flushvalve.
• Selectable sensing distance: 24 to 56" in 8" increments Factory set to 40"
• 24 hour courtesy flush factory set to off.
URINAL OPERATION:
• 8 second blocking time.
• 0 second activation delay.
• Adjustable flush volume using adjustment screw on flushvalve.
• Selectable sensing distance: 12 to 28" in 4" increments Factory set to 20"
• Adjustable 24 hour courtesy flush factory set to on.
1600T6103RI
and
1600T6103TR
Typical
Installation
1600T6403RI
and
1600T6403TR
Typical
Installation
TRANSFORMERS:
060704A 110 to 24VAC Class II 20VA (For 5 Sensor Modules) 060771A 110 to 24VAC Class II 40VA (Up to 10 Sensor Modules) 060772A 110 to 24VAC Class II 100VA (Up to 25 Sensor Modules)
CORDS:
060680A 4' Solenoid Extension Wire
HARDWIRE CONVERTER:
060683A 24VAC to 6VDC
Converter (Supplied standard on Hardwire models)
061047A 24VAC to 6VDC
Converter with Battery Backup (Standard on “-BB” models)
FLUSH VOLUME OPTIONS
Fixture # 1, 2 or 3 (Factory set at 60 psi)
Suffix Add Suffix to “RI” Product Number
None
6 litre (1.6 US gal) Adjustable
-6
6 litre (1.6 US gal) Not field adjustable
-48
4.8 litre (1.27 US gal) Not field adjustable
FLUSH VOLUME OPTIONS
Fixture # 4 (Factory set at 60 psi)
Suffix Add Suffix to “RI” Product Number
None
1.9 litre (0.5 US gal) Adjustable
-38
3.8 litre (1.0 US gal) Not field adjustable
-19
1.9 litre (0.5 US gal) Not field adjustable
-05 0
.5 litre (0.13 US gal) Not field adjustable
305mm (12") Square Frame
Flush Valve
Access Box Frame
356mm (14") Square Stainless Steel Cover
Sensor
Seat
76mm (3")
of Sensor
Outlet Parts
Tubing, Elbow, Wall and Spud Flange, Spud Nut, etc. Supplied as Required for Fixture Specified.
Note:
Recommended
height to sensor
from top of
fixture is
20-22" with
24" max.
Flushvalve
Access Box Frame
305mm (12") Square Frame
of sensor
Outlet Parts
Tubing, Elbow, Wall and Spud Flange, Spud Nut, etc. Supplied as Required for Fixture Specified.
(Except For 3/4" and 1 1/4" Top Inlet Urinal Fixtures.)
76mm (3")
Sensor
279mm (11")
TECK
®
COMMERCIAL
HARDWIRE WITH BATTERY BACKUP
Add suffix “-BB” to TR
Product Number. See DSP-BB for detailed specification.
Loading...