Installation Instructions / Warranty
Starck
10456XX1
90550101 01/2005
Starck free-standing tub filler trim
10456XX1
Technical Specification
Maximum water pressure 145 psi
Recommended water pressure 14.5 - 72 psi
Maximum hot water temp. 176
Recommended hot water temp 120
Max. flow rate @ 45 psi 5.8 gpm
This unit is not anti-scald. If anti-scald capability is
desired, is or required by local plumbing codes, install remote pressure balancing valve 13418181 to the hot and
cold supplies before they go into the 10452181 rough.
The handshower is protected against back siphonage with
a check valve. The check valve should be inspected and
cleaned yearly.
Installation considerations:
Rough-in 10452181 must be installed, and the finished
floor complete before installation of this trim kit.
An 8 mm allen wrench (not included) is required for
installation. 8 mm allen wrenches are available at hardware and auto parts stores.
o
*
o
- 140o*
Installation with Hoesch
Philippe Starck Edition
II tub
*Many municipalities require that the water heater be set no higher than 120o. Please know and follow all applicable plumbing codes when setting
the temperature on the water heater.
2
Installation Instructions
• Turn off the water at the main.
• Cut the plaster shield so that it extends 3/8" above the surface of
the finished floor.
• Use an 8 mm allen wrench (not included) to remove the three
screws from the flush housing. Remove the flush housing. Do not
discard the screws.
• Use the reserved screws to attach the trim to the rough. Pivot the
top of the trim so that the spout faces the correct direction. Use
a level to make sure that the unit is straight.
• Seal the floor around the plaster shield with a waterproof,
3