Faber SOTTILE SLIM Series, FWH SOTTILE 306, FWH SOTTILE 307, FWH SOTTILE 308AC, FWH SOTTILE 309DC User Manual

Page 1
INSTANT WATER HEATER
USER MANUAL
MODEL: SOTTILE SLIM SERIES
FWH SOTTILE 306 FWH SOTTILE 307 FWH SOTTILE 308AC FWH SOTTILE 309DC
1
Page 2
Thank you for purchasing FABER Instant Water Heater.
1. The appliance is not be used by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
2. Children being supervised to ensure that they do not play with the appliance.
3. Do not install reverse INLET & OUTLET of heater.
4. Do not install the heater where there is consistent spray directly over the unit.
5. Do not connect the OUTLET to any tap or fitting that is not recommended by the manufacturer.
6. Do not block the heater OUTLET in any way.
7. Do not attempt to repair the heater without qualified technician.
8. Do not leave children. elderly or disable person alone in shower.
9. Engage qualified electrician for installation.
10. Test water temperature with hand before using the shower.
11. Check the ELCB once a month (please refer to the RUN of Heater) and consult professional for repair if there is any malfunction.
12. Metallic / chrome flexible hose and conductive control value shall not be used.
13. Do not leave the hand shower idle in the pail.
14. Use only new hoses to connect the appliance to the water supply. The old hose-sets should not be reused.
15. This appliance is not to be used for portable water supply.
Page 3
EXTERNAL PARTS IDENTIFICATION
Heater LED
Temperature Control Knob
INTERNAL PARTS IDENTIFICATION
Terminal Block
Cable Entry
Booster Pump
Booster Pump Control Knob
Test & Reset
PCB
Power LED
ABS Front Cover
N
L
ABS Heater Base
ELCB Control Board
Thermal Cut Out
LED Display Board
Heater Tank
Triac
Heater Control Unit
Water INLET
Connection
Water OUTLET
Connection
Page 4
SHOWER SET ACCESSORIES IDENTIFICATION
1. CHROME/ WHITE ACCESSORIES
Wall Bracket
Hand Shower
Shower Holder
Slider Railbar
Wall Bracket
150mm Flexible Hose
G1/2
Page 5
SHOWER SET ACCESSORIES IDENTIFICATION
2. RAIN SHOWER SET
Water Saver
Chip
Water Saver
Chip
5 mm
0 mm
3
5
6
6
2
1
Slide down and hook the assembled diverter to the mounted square bracket
Tighten the
bottom screws
STEP 1
There is two Water Saver Chips located under the hand shower and on top of the rain shower head.
Water Saver Chip
A chip that helps you save water up to 50%!
ALERT
You may remove the two water saver chips if prefer stronger water pressure. Please be reminded that this is up to personal preference.
Rain Shower Head
Wall Bracket
Hand Shower
Shower Holder
Silding Rail
Soap Dish
Diverter
STEP 2
Do marking for the location of the lower square and upper round bracket. Install the bracket holders on the wall.
Assemble the upper tube with rain shower and lower tube with divider.
Slide down and hook the assembled diverter to the mounted square bracket.
Tighten the screws and make sure all joints are completely connected to avoid leakage.
360 Degrees 3-in-1 Rotation Diverter
360˚
180˚
5
90˚270˚
Page 6
2. GENERAL INFORMATION
INSTALLATION
CAUTION: THIS APPLIANCE MUST BE EARTHED
1. All the plumbing work should be completed before proceeding to electrical wiring connection. (Table 1)
2. Installation must be carried out by a qualified electrician with close reference to the operation manual and in compliance with the local regulations.
3. The unit works at minimum water flow rate of 2 litre/min, which then would trigger the bulit-in pump (only for pump model), boostering a stronger shower spray.
4. The bulit-in electronic Earth Leakage Circuit Break (ELCB) would cut-off the power supply to the heater in the event of current leakage of as low as 15mA.
5. The Thermal Cut-Off would automatically shut off the power supply shall there be any abnormal rise of showering temperature.
6. The unit only operates when there is sufficient water flow to trigger the flow switch.
7. Electrical loading Table 1:
2
8. Instantaneous water heater’s shall be equipped with a 2 pole control switch and is own residual current device.
9. Water heaters exceeding 3kW shall be permanently connected to a 20A/30A rated circuit breaker / fuse with an isolator switch and residual current device.
6
Page 7
3. INSTALLATION PROCEDURES
1. All the plumbing works should be completed before proceeding to electrical wiring connection.
2. INLET and OUTLET connection of the heater unit should not be reversed, with stop valve installed on INLET. (Diagram 1)
3. It is recommended that the unit should be mounted above 1.5m or 5-feet above the floor to bottom of the heater. (Diagram 1)
4. Mark mounting position (Diagram 2)
• Remove screw at the bottom of the heater
• Lift the plastic cover upward
• Mark mounting position on the wall
• Drill the holes with 5.0mm diameter drill bit
• Install the unit to the wall with plug
5. Heater INLET and OUTLET Connection (Diagram 3)
a) Connect the stop valve to INLET, and be sure to put a gasket to prevent water leakage.
b) Connect the piping from the stop valve to incoming water supply. If necessary, make use of sealing tape for the connection to prevent water leakage.
c) Connect flexible hose to heater OUTLET. Turn on the water mains to drain out all the plumbing dirt and fill up the heater tank. Then, connect the flexible hole to the hand shower. (Note: This step will prevent damage to the heating element).
stopvalve
incoming
water
INLET
OUTLET
SAFETY PRECAUTION
Do not install reverse INLET and OUTLET of heater
Stop Valve
correct installation inlet - outlet reverse
Inlet
Outlet
(wrong installation)
Inlet
stop valve
Outlet
Diagram 3
7
stop valve
Outlet
Inlet
stop valve reverse
(wrong installation)
Page 8
6. Electrical Connection
a) Insert electrical cable through the rubber grommet as shown.
b) Connect the cable to the terminal block and fully tighten them as the following:-
Red or Brown........................................ Live (L)
Black or Blue.......................................... Neutral (N)
Green or Green/ Yellow....................... Earth
c) Restore the cover and secure screw at the bottom. (Diagram 4)
d) Align the knob, from ‘OFF’ position in clockwise direction to ‘MAX’ and return to ‘OFF’ mark as shown (Diagram 5)
Restore cover
STEP 1
STEP 2
Diagram 5
Test Run Of Heater:
a) Turn on the stop valve and water should spray out from shower head.
b) Switch on the main power supply (“POWER LED would light up).
c) Turn on the Temperature Control Knob and ‘HEATER’ LED would light up.
The water should be warmed in a few seconds.
d) Turn on the Pump Control Knob to accelerate water flow.
(For Pump model only)
e) Test the ELCB by pressing ’TEST’ button. The unit should be tripped. ‘POWER’ and ‘HEATER’ LEDs would light off.
f) Press ‘RESET’ button, The unit should resume to normal condition.
g) The heater is now ready for use.
Diagram 4
8
Page 9
4. OPERATION PROCEDURE
1. Switch on the main power supply, the ‘POWER’ LED would light up.
2. Turn on the water supply at the stop valve.
3. Turn on the Temperature Control Knob. The ‘HEATER’ LED would light up and the water temperature will be increased accordingly as the knob being turned clockwise from ‘ON’ to ‘MAX’.
4. For normal cold shower, just turn the Temperature Control Knob to ‘OFF’ position.
5. Switch off the power supply when not in use.
5. GENERAL MAINTENANCE
DO NOT USE THINNER, ALCOHOL OR PETROL
You may clean the heater with a damp cloth and mild detergent but do not use thinner, alcohol, petrol or any other organic solution.
CLEAN FILTER REGULARLY (Diagram 6)
a) Remove the filter mesh at the stop valve (for filter type only) by turning the knob filter counter clockwise direction and pull out the knob (Diagram 6). Flush it with water to remove any trapped sediments. Install the knob filter back to its original position.
stop valve
CLEAN
REGULARLY
Diagram 6
9
Page 10
6. TECHNICAL SPECIFICATION
3.6kW 240V 50/60Hz
Please refer Electrical loading Table 1
6 bar ( 0.6MPa / 87psi )
440(H) x 230(W) x 80(D)
Non Pump 1.4kg Inverter Silent Pump1.9kg AC Pump 2.2kg
Notes: The specification, actual product’s design and accessories parts shown are correct at the time of printing and subject to change without prior notices.
7. SCHEMATIC WIRING DIAGRAM
INVERTER SILENT PUMP (FWH SOTTILE 309DC)
10
Page 11
AC PUMP (FWH SOTTILE 308AC)
NON -PUMP (FWH SOTTILE 306/307)
11
Page 12
12
Loading...