12GB
CONTENTS
Dear Customer, If you follow the recommendations contained in this Instruction
Manual, your appliance will give you constant high performan­ce and will remain efficient for many years to come.
RECOMMENDATIONS AND SUGGESTIONS 13 CHARACTERISTICS 14 INSTALLATION 16 USE 19 MAINTENANCE 20
Page 3
13GB
RECOMMENDATIONS AND SUGGESTIONS
INSTALLATION
The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
The minimum safety distance between the cooker top and the extractor hood is 650 mm.
Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
USE
The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
Never use the hood for purposes other than for which it has ben designed.
Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
The hood should not be used by children or persons not instructed in its correct use.
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
Clean and/or replace the Filters after the specified time period.
Clean the hood using a damp cloth and a neutral liquid detergent.
650 mm min.
Page 4
14GB
CHARACTERISTICS
Dimensions
650 min.
90
135
500
676 70
898
ø 340
ø 150
min. 890
max. 1170
890
Page 5
15GB
12f
2
2.1
2.2
11
12h
22
23
21
7.1
1
14.1
15
12g
14
25
8
24
12e
12c
7.1a
7.1b
Components
Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light,
Blower, Filters
2 1 Telescopic Chimney comprising:
2.1 1 Upper Section
2.2 1 Lower Section
7.1 1 Telescopic frame complete with extractor,
consisting of:
7.1a 1 Upper frame
7.1b 1 Lower frame 8 1 Air Outlet Grill 9 1 Reducer Flange ø 150-120 mm 14 1 Hood Body Air Outlet Extension Piece
consisting of two Half Shells
14.1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection 24 1 Junction box 25 2 Pipe clamps
Ref. Q.ty Installation Components 11 4 Wall Plugs ø 10 12c 4 Screws 2,9 x 6,5 12e 2 Screws 2,9 x 9,5 12f 4 Screws M6 x 10 12g 4 Screws M6 x 80 12h 4 Screws 5,2 x 70 21 1 Drilling template 22 4 6.4 mm int. dia washers 23 4 M6 nuts
Q.ty Documentation
1 Instruction Manual
Page 6
16GB
INSTALLATION
Drilling the Ceiling/shelf and fixing the frame
DRILLING THE CEILING/SHELF
Use a plumb line to mark the centre of the hob on the ceiling/support shelf.
Place the drilling template 21 provided on the ceiling/support shelf, making sure that the template
is in the correct position by lining up the axes of the template with those of the hob.
Mark the centres of the holes in the template.
Drill the holes at the points marked:
For concrete ceilings, drill for plugs appropriate to the screw size.
For hollow brick ceilings with wall thickness of 20 mm: drill ø 10 mm.
For wooden beam ceilings, drill according to the wood screws used.
For wooden shelf, drill ø 7 mm.
For the power supply cable feed, drill ø 10 mm.
For the air outlet (Ducted Version), drill according to the diameter of the external air exhaust
duct connection.
FIXING THE FRAME
Before fixing, separate the Upper Section 2.1 and the Lower Section 2.2 from the Frame by unscrewing the screws 12c, then separate the two sections of the frame by unscrewing the 6 side screws to obtain the Upper frame and Lower fra­me.
Page 7
17GB
Upper frame
Align the power supply cable feed hole
Fix the upper frame to the ceiling or shelf using:
For concrete ceilings, use the appropriate plugs for the screw size (not provided).
For hollow brick ceilings of wall thickness of approximately 20 mm: use 4 plugs 11 and 4
screws 12h, provided.
For wooden beam ceilings, use 4 wood screws (not provided).
For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided.
Lower frame
Fix the lower frame using the 8 previously removed screws, adjusting the length according to the installation height (hood body lower fixing surface must be at least 720 mm from the hob).
For the recirculation version, turn the frame in the direction chosen for the recirculated air outlet.
The frame mountings must be secure to withstand the weight of the hood and any stresses caused
by the occasional side thrust applied to the device. On completion, check that the base is stable, even if the frame is subjected to bending.
In all cases where the ceiling is not strong enough at the suspension point, the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.
Fix the pipe using the pipe clamps 25 provided.
Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
Insert reducer flange 9 on the extractor outlet.
Push fit the extension piece 14 onto the flange.
Push fit connector 15 onto the extension piece.
Insert extension piece/connector 14.1 laterally
on connector 15, ensuring that the outlet is in line with the chimney intake.
9
ø 120ø 150
15
14.1 14
9
Page 8
18GB
12f
8
24
12e
Cmd
12c
Lux
Flue assembly - Mounting the hood body
Position the upper chimney section and fix the
upper part to the frame using the 2 screws 12c provided.
Fit the lower chimney section onto the frame, holding it in place until the hood body has been fixed in place.
Recirculation version
Make sure that the outlet of the extension piece
14.1 is horizontally and vertically aligned with the chimney outlet.
If this is not the case, remove the lower chimney section and adjust the position by cutting the hood body extension 14 along one of the thinner section channels denoting the pre-fixed lenghts, then reassemble as described previously.
Before fixing the hood body to the frame:
Remove the grease filters from the hood body;
Remove any activated charcoal filters.
From below, use the 4 screws 12f provided to
fix the hood body to the frame.
For the recirculation version, locate the directional grill 8 in its housing. Ensure that it is inserted correctly in connector 15.
ELECTRICAL CONNECTION
Connect the hood to the mains through a two­pole switch having a contact gap of at least 3 mm.
Connect the control connector Cmd.
Connect the lights connector Lux.
Place the connectors in the junction box 24 and
close it using the 2 screws 12e (2,9 x 9,5) provided.
Fix the junction box to the hood body using the 2 screws 12c (2,9 x 6,5) provided.
For the recirculation version, fit the activated carbon odour filter.
Replace the grease filters.
Page 9
19GB
USE
Control panel
L Light Switches the lighting system on and off. S1 Led Motor running led. Flashes when the grease filters are saturated. S2 Led Intensive speed led. Flashes when the activated carbon odour filters are exhausted. M Motor Switches the extractor motor on and off at low speed. Used to provide a contin-
uos and silent air change in the presence of light cooking vapours. When the Hood is in ELC (Electronic Comfort) mode, the button will not only
turn the Ducting motor on, but will also disable this function.
V1 Speed Reduces the operating speed.
When the button is pressed with the Motor off, ELC (Electronic Comfort) mode will be enabled again, giving a continuous, low noise flow of air. Press the button and hold it until Led S1 flashes slowly.
V2 Speed Increases the operating speed. V3 Intensive Maximum speed, used for eliminating the highest cooking vapour emission.
speed Switches off automatically after 10 minutes operation. Can also be switched off
manually by pressing the button.
Page 10
20GB
MAINTENANCE
Grease filters
CLEANING METAL SELF-SUPPORTING GREASE FILTERS
Alarm signal reset
Switch off the lights and extractor motor.
Press button V3 for at least 3 seconds, until the
leds start to flash.
Cleaning the filters
The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of operation, or more frequently for particularly heavy usage.
Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
Wash the filters, taking care not to bend them. Allow them to dry before refitting.
When refitting the filters, make sure that the handle is visible on the outside.
Page 11
21GB
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
The filter is not washable and cannot be regenerated. It must be replaced when led S2 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on.
Alarm signal reset
Switch off the lights and extractor motor.
Press button V3 for at least 3 seconds, until the
leds start to flash.
Replacing the Filter
Remove the metal grease filters
Remove the saturated activated carbon filter by
releasing the fixing hooks
Fit the new filter by hooking it into its seating
Replace the metal grease filters.
Alarm signal activation
On the recirulcation version extractor hood, the filter saturation alarm is activated during installation or at a later date.
Switch off the lights and extractor motor.
Press button V3 for at least 10 seconds, until
the leds start to flash:
2 flashes of the activated carbon odour filter saturation alarm led = filter ACTIVATED
1 flash of the activated carbon odour filter saturation alarm led = filter DEACTIVATED
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the 2 screws fixing the ring nut.
Extract the lamp from the lamp holder by pulling
gently.
Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
Replace the ring nut and fix it in place using the two screws removed as above.
Page 12
Quest’apparecchio è conforme alla norma europea sulla bassa tensione C.E.E. 73/23 relativa alla sicurezza elettrica e alle norme europee: C.E.E. 89/336 relativa alla compatibilità elettromagnetica e C.E.E. 93/68 relativa alla marcatura CE.
This appliance conforms to European Low Voltage Directive 75/23/CEE governing electrical safety, European Directive 89/ 336/CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking.
Cet appareil est conforme à la norme européenne en matière de basse tension C.E.E. 73/23 de sécurité électrique ainsi qu’aux normes européennes : C.E.E. 89/336 en matière de compatibilité électromagnétique et C.E.E. 93/68 en matière de label CE.
Dieses Gerät entspricht folgenden EG-Richtlinien: Niederspannungsrichtlinie EWG 73/23 hinsichtlich elektrischer Sicherheit, Richtlinie Elektromagnetische Verträglichkeit EWG 89/336 und Richtlinie EWG 93/68 hinsichtlich der CE-Kennzeichnung.
Dit apparaat voldoet aan de Europese laagspanningsnorm 73/23/EEG inzake de elektrische veiligheid en de Europese normen: 89/336/EEG inzake de elektromagnetische compatibiliteit en 93/68/EEG inzake de CE-markering.
436001402 01 - 021104